§ 273-9 — Light, ventilation and heat
Code of the City of Clifton, New Jersey (Code 2026-10-20) · Clifton City Code § 273-9
Corpus is an independent public-information project, not the official City of Clifton website. Stable reference: corpuslaw.us/code/f21949d1-ef6c-4940-ab0e-98bde41eefb5
§ 273-9: Light, ventilation and heat.
No person shall occupy as owner-occupant or let to another for occupancy any dwelling or dwelling unit, for the purpose of living therein, which does not comply with the following requirements: A. Every habitable room shall have at least one window or skylight facing directly to the outdoors. The minimum total window area, measured between stops, for every habitable room shall be 10% of the floor area of such room. Whenever walls or other portions of structures face a window of any such room and such light-obstruction structures are located less than three feet from the window and extend to a level above that of the ceiling of the room, such window shall not be deemed to face directly to the outdoors and shall not be included as contributing to the required minimum total window area. Whenever the only window in a room is a skylight-type window in the top of such room, the total window area of such skylight shall equal at least 10% of such room. B. Every habitable room shall have at least one window or skylight which can easily be opened, or such other device as will adequately ventilate the room. The total of openable window area in every habitable room shall be equal to at least 45% of the minimum window area size or minimum skylight-type window size, as required in Subsection A of this section, except where there is supplied some other device affording adequate ventilation and approved by the Building Inspector. C. Every bathroom and water closet compartment shall comply with the light and ventilation requirements for habitable rooms contained in Subsections A and B of this section, except that no window or skylight shall be required in adequately ventilated bathrooms and water closet compartments equipped with a ventilation system which is kept in continuous operation and approved by the public officer. D. Every habitable room shall contain at least three separate wall-type electric convenience outlets, or two such convenience outlets and one ceiling or wall-type electric light fixture. Every such outlet and fixture shall be maintained in good and safe condition and shall be connected to the source of electric power. No temporary wiring shall be used except extension cords which run directly from portable electrical fixtures to convenience outlets, and which do not lie under rugs or other floor coverings, nor extend through doorways, transoms or other openings through structural elements. E. It shall be the duty of every person who shall have contracted, undertaken or shall be bound to heat or furnish heat for any building or portion thereof, occupied as a home or place of residence of one or more persons, to comply with the provisions of Chapter 269, Heating of Buildings. F. Every portion of each staircase, hall, cellar, basement, landing, furnace room, utility room, and all similar nonhabitable space located in a dwelling shall have either natural or artificial light available at all times, with an illumination of at least two lumens per square foot (two footcandles) in the darkest portions. Every portion of any interior or exterior passageway or stairway common to two or more families in a dwelling shall be illuminated by at least two lumens per square foot (two footcandles) in the darkest portion of the normally traveled stairs and passageways. In dwellings comprising two dwelling units, such illumination shall not be required at all times if separate switches, convenient and readily accessible to each dwelling unit, are provided for the control of such artificial light by the occupants thereof. G. During that portion of each year when the Health Officer deems it necessary for protection against mosquitoes, flies and other insects, every door opening directly from a dwelling unit to outdoor space shall have supplied screens and a self-closing device. Every window or other device with openings to outdoor space used or intended to be used for ventilation shall likewise be supplied with screens. H. Every basement or cellar window used or intended to be used for ventilation, and every other opening to a basement which might provide an entry for rodents, shall be supplied with a screen or such other device as will effectively prevent their entrance. I. Every space heater, except electrical, shall be properly vented to a chimney or duct leading to the outdoors. Unvented portable space heaters burning solid, liquid or gaseous fuels shall be prohibited.
[Amended 7-5-1967 by Ord. No. 3782 ]
Ask a question about Clifton law
Corpus searches the Clifton sections it holds and shows the ones that match, with their citations. Free, no sign-in.