§ 15.08.080 — Modifications and supplements to the New Jersey Fire Prevention Code.*
Code of Ordinances of the City of Elizabeth, New Jersey (Supp. No. 31: codified through Ordinance No. 6138, passed June 24, 2025) · Elizabeth City Code § 15.08.080
Corpus is an independent public-information project, not the official City of Elizabeth website. Stable reference: corpuslaw.us/code/0cbb4293-dd6c-45e7-bd39-d668fd699de8
15.08.080 - Modifications and supplements to the New Jersey Fire Prevention Code.*
A. Modifications. The following sections of the New Jersey Uniform Fire Code are modified as provided in this section: [F-305.3 INSIDE STORAGE: Storage in buildings and structures shall be orderly, shall not be within 2 feet [610 mm] of the ceiling, and located so as not to obstruct egress from the building.] "SECTION F-305.3 INSIDE STORAGE Storage in buildings and structures shall be orderly, shall not be within two (2) feet of the ceiling, shall be located so as not to obstruct egress from the building, and shall further conform to NFiPA Standards 231, 231A, 231B, and 231C, except as such standards may be in conflict with the New Jersey Uniform Construction Code." [F-400.2 INSTALLATIONS: Before any fire alarm, detection or fire suppression system is installed, enlarged or extended, a permit shall be secured from the building official. Plans and specifications shall be reviewed by the fire official prior to the issuance of the building permit.] "SECTION F 400.2 INSTALLATIONS: Before any fire alarm, detection or fire suppression system is installed, enlarged or extended, a construction permit shall be secured from the Construction Official. Plans and specifications shall be reviewed by the Fire Official and Fire Sub Code Official and Superintendent of Communications prior to the issuance of the building permit." [F-1700.1.1 PERMIT REQUIRED: A tent or air-supported structure covering an area in excess of 120 square feet [11.16m2], including all connecting areas or spaces with a common means of egress or entrance, and used or intended to be used for gathering together of ten or more persons shall not be erected, operated or maintained for any purpose without obtaining a permit from the building official and the fire official. Tents used exclusively for recreational camping purposes shall be exempt from the above requirements. Special permits required by the building code shall be secured from the building official.] "SECTION 1700.1.1 PERMIT REQUIRED: A tent or air-supported structure covering an area in excess of 120 square feet, including all connecting areas or spaces with a common means of egress or entrance and used or intended to be used for gathering together of ten or more persons shall not be erected, operated or maintained for any purpose without obtaining a permit from the Fire Official & Building Official. Tents used exclusively for recreational camping purpose shall be exempt from the above requirements. Also a certificate of flame resistance shall be submitted to the Fire Official for all tents over 120 square feet. Any tent used for cooking foods must have at least 1-10 pound ABC dry chemical extinguisher at their location when cooking." [F-2701.2 BOND FOR DISPLAY: The permittee shall furnish a bond in an amount deemed adequate by the fire official for the payment of all damages which may be caused either to a person or persons or the property by reason of the permitted display, and arising from any acts of the permittee, the permittee's agent, employees or subcontractors.] "SECTION F2701.2 BOND FOR DISPLAY Before any permit for a fireworks or pyrotechnic display shall be issued, the person, firm or corporation seeking such a permit shall first make application to the City Clerk of the City of Elizabeth and furnish proof of financial responsibility to satisfy claims for property damage or personal injury arising out of any act or omission on the part of such person, firm, or corporation that such amount is not less than one million dollars ($1,000,000.00), and in such form as the City Clerk, the City Attorney and the City Council of the City of Elizabeth determine to be necessary for the protection of the public." SECTION F-5601.2 PERMIT REQUIRED FOR SEASONAL SALE Permit required. The seasonal (May 1 through September 15 of each year) sale of fireworks and sparkling devices and novelties as set forth in N.J.S.A. 21:3-2 within the City of Elizabeth shall be allowed with the permit authorizing such from the Chief License Inspector from the City of Elizabeth. The process for applying for such a permit is set forth in Chapter 5.38 of this Code and shall require the approval of both the Chief License Inspector and the Fire Official. This permit does not waive the State permit requirement for the storage and retail of sparkling devices and novelties in temporary or permanent structures when the pyrotechnic content exceeds 125 pounds as set forth in N.J.A.C. 5:70-2.7. Fees. Prior to the issuance of a fireworks permit by the Chief License Inspector, the applicant shall have paid a fee of one hundred dollars ($100.00) for the seasonal sale of fireworks. A new permit and appropriate fee shall be furnished for every new season. [Article 30. LIQUEFIED PETROLEUM GASES.] "Article 30 LIQUEFIED PETROLEUM GAS AND LIQUEFIED NATURAL GAS." B. Supplements to the New Jersey State Fire Prevention Code. 1. Testing. Periodic tests of underground tank storage systems may be required by the fire official to determine that leakage has not occurred. Such periodic testing shall be required of all existing underground Class I flammable liquid storage tanks and associated piping systems as specified herein. a. All underground Class I flammable liquid tanks shall be tested every five years after the last hydrostatic test. If a test has not been performed as of the effective date of the ordinance codified in this chapter, testing must be completed by the end of 1986. b. Any devices used for testing shall be capable of detecting leaks as small as five one-hundredths gallon in one hour, in the tanks or piping systems after adjustments are made for variables. 2. Plumbers' Torches and Lead Pots. Any person using a torch or other flame-producing device for sweating pipe joints, thawing frozen pipes, melting lead or other similar operations in any building or structure shall have available in the immediate vicinity where such work is being done one approved fire extinguisher or water hose connected to a water supply. Combustible materials in the close proximity of the flame shall be protected against ignition by shielding, wetting or other approved means. In all cases, a fire watcher shall remain in the vicinity of such operations for at least one-half hour after the torch or flame-producing device has been used. 3. Ordinary Combustible Materials. Ordinary combustible materials or storage of ordinary combustible materials in motor freight terminals, warehouses or distribution centers, and when stored for use in manufacturing or industrial plants or processes a permit shall be obtained from the fire official. No permit shall be required for storage in conjunction with retail sales. 4. Outdoor Barbecuing and other Fires. Charcoal or other fires for cooking (except gas and electric cooking equipment) or other purposes on balconies, fire escape, combustible roofs or inside of any building or structure are hereby prohibited. Except as prohibited, these fires shall be kindled only on a proper receptacle designed for that purpose, and shall be located so that the receptacle is at least ten (10) feet from combustible buildings or structures on the same or adjoining property. Flammable liquids shall not be added once the fire is started. 5. Establishment of fire lanes or zones on private property devoted to public use, or to which the public is invited. Fire lanes or fire zones on private property devoted to public use, or to which the public is invited, are hereby established as follows: a. Those portions of such properties which the fire official shall designate, shall be those areas of such properties where the parking of motor vehicles or other obstructions may interfere with the ingress or egress of persons or the ingress or egress of fire department vehicles or otherwise interfere with the operations of the fire department for the protection of persons or property, such as at, but not limited to, shopping centers, bowling alleys, theaters, hospitals, churches, schools, places of assembly, and similar locations including residential properties. b. When it is necessary for the fire official to establish or designate such lanes or fire zones he shall notify the owner or other person, firm, company or corporation having control of the property in writing by registered or certified mail, or by hand delivering such notice, specifically describing the area designated and the reason for making the designation. The lanes or zones shall be properly marked by the owner, person, firm, company or corporation having control, at their own expenses and within thirty (30) days after receipt of the notice. 6. Mercantile Occupancies. All mercantile occupancies shall be provided with at least one fire extinguisher, suitable for the class of fire that is likely to occur. Fire extinguishers shall be provided on the basis of one for each twenty-five hundred (2,500) square feet or fraction thereof and so located that there shall be a minimum of fifty (50) feet travel distance. If there is more than one level used for storage and/or retail sales, there shall be at least one at each level. 7. Emergency Lighting. Emergency lighting facilities shall be installed in each assembly occupancy having an occupant load of one hundred (100) or more in educational, industrial, institutional occupancy; and in windowless building which the fire official deems necessary, in order to provide reasonable safety for the occupants. 8. Location. No heliport, helistop or stol (short take-off and landings) port shall be located within the city unless specifically approved by the fire chief, police chief, municipal council, fire official, and the construction official and the planning board. 9. Fire Watch. The use in any building with a permitted occupancy of one hundred (100) or more persons for the amusement, entertainment, sporting events, shows or religious events, shall have the fire official or his designee, certified fire inspectors and firefighters in attendance at all functions as required by the fire chief and fire official and this code. 10. Pyrotechnics. Any time pyrotechnics are used in a structure, the fire official or his designee, certified fire inspectors, and firefighters will be in attendance at all such functions as required by the fire chief and fire official and this code. 11. Service Stations. The use of the premises of service stations for the storage of old and discarded tires or flammable scrap parts is prohibited, and the parking and storage of vehicles so as to impede proper ingress or egress to the premises is also prohibited. 12. Fire Safety Requirements Construction and Protection Requirements. Handling and storage of large quantities of waste-paper, rags or used rubber tires and other waste materials of a flammable nature shall not be in a building of wood frame or ordinary construction unless the building is sprinklered. 13. Loose Paper to be Baled. Large quantities of loose combustible material shall not be permitted to accumulate but shall be baled so that such quantities may be kept at a minimum, and all such material shall be baled by the end of the working day. 14. Tank Size and Location with Respect to Property Lines. Aboveground tanks for the storage of flammable or combustible liquids shall not exceed two hundred (200) feet in diameter and shall not exceed sixty-four (64) feet in height. Tanks shall be the required distances from property lines and public ways, regardless of whether the adjoining property may be built upon. Refer to Title 17 of this code. 15. Spacing between Aboveground Tanks. When tanks located aboveground are sixty (60) feet or larger in diameter, there shall be not more than two rows of tanks without an intervening roadway having a minimum width of fifteen (15) feet and a fire service water main of at least six inches in diameter having fire hydrants spaced not more than three hundred (300) feet apart. Where a roadway is required the flat section at the top of a dike may be used, provided it can support the weight of fire apparatus vehicles and is at least fifteen (15) feet wide at the narrowest point. 16. Drainage, Dikes and Walls. In addition to other requirements, the following regulations shall be complied with: a. All tanks containing flammable or combustible liquids having a flash point below two hundred fifty (250) degrees shall be diked or be provided with drainage to a safe area. b. There shall be not more than three tanks within a common dike when such tanks are sixty (60) feet or more in diameter and contain Class I flammable liquid. c. There shall not be more than six tanks within a common dike when such tanks are sixty (60) feet or more in diameter and contain liquids having a flash point at or above one hundred (100) degrees and below two hundred (200) degrees Fahrenheit. d. When tanks are less than sixty (60) feet in diameter, the number of tanks within a common dike shall be limited to such number as can be effectively protected by hose streams. e. Height of dike walls shall be limited to a maximum of six feet, measured from the interior of the diked area. f. Piping supports within dike areas shall be of materials that have a fire resistance rating of at least two hours. All pipe systems shall be substantially supported and protected against physical damages, and excessive stresses arising from settlement, vibration, expansion or contraction. 17. Piping to Underground Flammable Liquid Tanks. All alteration, repair or modifying of piping or dispensing units in relation to underground flammable and combustible liquid tanks shall require a permit from the fire official. 18. Water Supply. A water supply and distribution system shall be included as part of all bulk storage plants. The minimum fire flow shall be sufficient to provide protection for the largest tank in the plant or the greatest hazard within the plant and to provide sufficient additional flow to protect and cool exposed tanks or other property. The installation of water lines for plant protection shall comply with the applicable provision of NFiPA Standard 24, the most recent edition of "Outside Protection." 19. Tank Protection. Suitable fire suppression systems shall be required to protect all aboveground storage tanks containing liquids having a flash point less than two hundred (200) degrees Fahrenheit. The suppression system shall be sufficient additional capacity and equipment to control fires. Supply piping and manifolds for foam or other approved suppression systems shall not be located inside of diked areas, except as necessary to deliver the extinguishing agent to the tank being protected. An adequate supply of the appropriate type of foam concentrate for the system shall be stored on the premises. 20. Inspection Permit Fee Required. No person shall engage in the business of delivering flammable or combustible liquids from tank vehicles without first having obtained a permit from the fire official, except that deliveries made to bulk plants suitable fire control equipment need not require a permit. 21. Prohibited Materials. All chemicals and materials possessing a health hazard greater than "3" or a reactivity hazard greater than "3" as identified in accordance with the most recent edition of the NFiPA Standard 49 "Hazardous Chemical Data" and NFiPA Standard 325 M "Fire Hazard Properties of Flammable Liquids" for the Fire Hazards of materials, are hereby prohibited to be stored in bulk within the city limits of the city. The fire official may permit limited amounts to be stored when they are to be used in conjunction with chemical or industrial processes, when application is made in writing and the fire official is satisfied that the safety precautions to be taken in the storage and handling of such materials will not pose an unreasonable risk of hazard to persons or property. No increase in the amounts which may be allowed shall be permitted except on new written application to the fire official. 22. Identification of the Fire Hazard or Materials. All chemicals in storage and in use shall be identified both as to the type of hazard and the degree of hazard in such manner as to reveal at a glance to firefighters and other interested persons proper precautions and actions to be taken to safeguard life and property. Identification shall be made for health, flammability, and reactivity hazards of the materials, and the degree of each of these hazards. This identification shall be made in accordance with methods outlined in the most recent edition of the NFiPA Standard 704, "Identification System for the Fire Hazards of Materials." 23. Proper Designation of Hazard. All hazard symbols used shall be proper for the material which is being identified. In the event of doubt as to how the symbol should be displayed, the fire official shall be consulted. It shall remain the responsibility of the person, company, firm or corporation to supply all the information necessary to arrive at a proper designation for each hazard that may be involved. It shall be the duty of the person, company or firm or corporation to check as often as necessary to insure that all identification is proper, and accurately describes the true nature of the materials, and is kept up to date. 24. Exceptions and Records. All requests for variance from the strict compliance with NFiPA Standard 704 shall be made in writing to the fire official stating the reason for the request and suggesting an alternative type of container and identification symbol assigned to it shall be kept on the premises and shall be available to the fire department on request. 25. Additional Inspection Permits Required. Annual inspection permits shall be required for all installations in which liquefied petroleum gas (LPG) or liquefied natural gas (LNG) is transferred from one container to another regardless of the size of the installation, and for the storage of cylinders inside a building. Such storage shall be limited to amounts and locations approved by the fire official. This shall apply to cylinders awaiting sale, reuse, empty awaiting exchange or used in connection with temporary heating equipment. 26. Definitions. For the purpose of this section and as used in this code, the following words and terms shall have the meaning indicated: "Liquefied natural gas" means a fluid in the liquid state composed predominately of methane and which may contain minor quantities of ethane, propane, nitrogen or other components normally found in natural gas. Also known by the abbreviation LNG. "Liquefied natural gas equipment" means all container apparatus, piping (not including utility distribution piping systems) and equipment pertinent to the storage and handling of liquefied natural gas. Gas consuming appliances shall be considered as being liquefied natural gas equipment. 27. Oil Burner Equipment—Scope. The installation, operation and maintenance of oil burning equipment, except combustion engines, oil lamps and portable devices such as flow torches, melting pots, weed burners and similar devices shall comply with the requirements of this code and the specific provisions of this section. 28. Definitions. For the purpose of this section and as used in this code, the following words and terms shall have the meaning indicated: "Conversion range oil burner" means an oil burner designed to burn kerosene, range oil or similar fuel. This burner is intended primarily for installation only in a stove, or range, a portion or all of which originally was designed for the utilization of solid fuel and which is flue-connected. "Fuel oil" means kerosene or any hydrocarbon oil conforming to nationally recognized standards and having a flash point not less than one hundred (100) degrees Fahrenheit. "Heating and cooking appliance" means an oil fired appliance not intended for central heating. These appliances include kerosene stoves, oil stoves and conversion range oil burners. "Oil burner" means a device for burning oil in heating appliances such as boilers, furnaces, water heaters, ranges and similar appliances. A burner of this type may be furnished with or without a primary safety control; and it may be a pressure atomizing gun type, a horizontal or vertical rotary type, or mechanical of natural draft vaporizing type. "Oil burning equipment" means an oil burner of any type together with its tank, piping, wiring, controls and related devices and shall include all oil burners, oil-fired units, and heating and cooking appliances but excluding those exempted by Section F 3400.1 of the New Jersey Uniform Fire Code. "Oil-fired units" means a heating appliance with one or more oil burners and all the necessary safety controls, electrical equipment and related equipment manufactured for assembly as a complete unit. This definition does not include kerosene stoves or oil stoves. 29. Inspection Permits Required. Inspection permits shall be obtained from the fire official for the installation of oil-fired equipment except when installed in connection with work requiring a construction permit in which case the Fire Protection Sub-Code of the state Uniform Construction Code shall apply. 30. Annual Inspection Permit. An annual inspection permit shall be required for a fuel oil tank when used in connection with an oil burning unit when the amount stored is in excess of twenty-five (25) gallons, if in the opinion of the fire official such installation created a hazard or constitutes a potential hazard. 31. Portable Space Heater Inspection Permit. An inspection permit shall be required for the use of a portable space heater used in conjunction with construction work. 32. Tank and Burner Inspection Permit. A single inspection permit shall be required for the initial installation of an oil burner and a fuel oil tank used in connection therewith that is in excess of twenty-five (25) gallons. A separate inspection permit shall be required for the replacement of a fuel oil tank connected to an oil burner. 33. Fire Safety Requirements—General. The layout, arrangement and construction of building and structures in which oil burning equipment is to be installed or used shall comply with the applicable requirements of the building code for the appropriate occupancy use group classification, and shall be provided with fire protection and fire extinguishing equipment as required by that code. Buildings and structures and their service equipment shall be maintained in proper operating condition as required by this code. 34. Use of Approved Equipment. Oil burning equipment shall be of an approved type as required by the building code. 35. Installation—Requirements. Oil burning equipment and systems shall be installed in accordance with the Building Subcode of the state Uniform Construction Code, the installation instruction of the manufacturer, and the most recent edition of the NFiPA 31. 36. Accessibility. The installation shall be such as to provide reasonable accessibility for cleaning heating surfaces, removing burners, replacing motors, controls, air filters, draft regulators and other working parts for adjusting, cleaning and lubricating parts requiring such attention. 37. Electrical Wiring and Equipment. Electrical wiring and equipment used in connection with oil burning equipment shall be installed and maintained in accordance with the current National Electrical Code, NFiPA 70 and in addition, the equipment shall be in a properly identified, direct separate line from the electrical service panel. A remote shut-off switch shall be installed at the top of the cellar stairs or at such other location as may be specified by the fire official. 38. Fuel Oil. The grade of fuel oil used in a burner shall be that for which the burner is approved and as specified by the manufacturer. Crankcase oil or any oil containing gasoline shall not be used. 39. Storage Tanks. Installation of fuel oil storage tanks shall comply with the requirements of this code, the Building Code and the NFiPA 31. 40. Use of Approved Equipment. No person shall use, keep for use, or store and maintain for use in any structure or portion of a structure a portable liquid-fuel-burning space heater. For the purpose of this article a portable liquid-fuel-burning space heater is defined as any heater, stove or appliance designed for heating space in structures, using or designed for using kerosene, liquid fuel or other flammable liquid, which is neither flue nor chimney connected, and which is not permanently affixed to any part of a structure and which is capable of being moved or upset. Within their assigned duties, any fire prevention member and/or company officer shall confiscate any portable liquid fuel burning space heater found in nay structure. 41. Conversion Burners. A conversion range oil burner shall be equipped with a thermal (heat actuated) valve in the oil supply line located in the burner compartment of the stove. 42. Small Appliances. Small heating and cooking appliances, including space heaters, shall be installed as specified in the most recent edition of the NFiPA Standard 31 and in addition shall be vented to a chimney or approved vent and shall be securely anchored to prevent movement and protected from physical damage. No small heating and cooking appliance shall be connected to a supply tank that exceeds a capacity of three gallons. 43. Article 35—Gas Piping and Appliance—General—Scope. This article shall apply to liquefied petroleum gas and natural gas piping and appliances used for heating, cooking or industrial purposes. 44. Inspection Permit Required. An inspection permit shall be required for the initial installation of gas-fired central heating units in all buildings. Gas-fired space heaters shall also require a permit except those designed to heat a single room of a dwelling unit. 45. Odorization Required. All gas supplied to customers shall possess a distinctive gas odor of sufficient strength to act as a warning of its presence, except gas for industrial process use if the odor used would contaminate or otherwise render the gas unfit for the process. Any gas not naturally possessing odor shall have an odorant added to it to meet this requirement. 46. Precaution in lieu of Odorization. When the addition of an odorant would render the gas unsuitable for use in industrial processes, the odorant may be omitted, provided there is installed gas detection equipment that continually monitors the atmosphere where the gas is used or stored to detect its presence and sound an alarm. 47. Installation Requirements—Gas Cocks Required. Every gas appliance shall have an approved gas cock installed near the appliance to shut off the gas supply while the appliance is being serviced or temporarily released. 48. Automatic Gas Shut-Off Valves. An automatic gas shut-off valve shall be installed in the gas supply to cooking appliances when such appliances are protected by approved fire suppression systems. The valve shall be arranged to automatically shut the gas supply off whenever the suppression system is activated by any means. It shall be so arranged that it cannot be opened until the suppression system has been restored. 49. Flexible Connectors. Only approved flexible connectors shall be used to connect a gas consuming appliance to the supply piping. The flexible connector shall be as short as practical with suitable clamps or threaded coupling to prevent accidental separation of the connectors. Flexible connections shall be installed only on the appliance side of gas cock. 50. Gas Appliance Piping and Venting. Gas appliances, piping and venting systems shall be installed in accordance with the requirements of the Building Code, Plumbing Code, and the most recent edition of the NFiPA Standard 54 National Fuel Gas Code. Where requirements differ, the requirement that offers the greatest of safety shall apply.
(Ord. No. 5175, § 9, 5-14-2019; prior code § 30-9)
Ask a question about Elizabeth law
Corpus searches the Elizabeth sections it holds and shows the ones that match, with their citations. Free, no sign-in.