§ 17.56.070 — Supplementary regulations for the location of towers
Code of Ordinances of the City of Elizabeth, New Jersey (Supp. No. 31: codified through Ordinance No. 6138, passed June 24, 2025) · Elizabeth City Code § 17.56.070
Corpus is an independent public-information project, not the official City of Elizabeth website. Stable reference: corpuslaw.us/code/223176f9-c089-4ffe-825e-fa725e2912ff
17.56.070 - Supplementary regulations for the location of towers.
A. Height and Setbacks. The construction of any new tower shall be only in accordance with all zoning regulations of the zone district in which the proposed tower is to be located and the following additional requirements: Minimum setback of tower from any property line | 100 feet Distance from: Any existing residence | 500 feet Another tower | 1,500 feet Minimum setback for equipment compound | As required by applicable zoning regulations for accessory uses and structures Maximum tower height | 150 feet Fencing | 10 feet high security mesh fence (no barbed wire) B. Visual Compatibility. The applicant shall comply with the visual compatibility requirements in Section 17.56.060 of this chapter and in addition, stealth designs shall be employed for proposed antenna support structures to conceal their appearance such as bell towers, artificial trees and similar treatments as approved by the city. C. Other Requirements for Towers. 1. Where new towers or replacements are proposed, the following shall be submitted: a. A report by a licensed professional engineer which, in the case of a tower, shall include: i. A detailed description of the proposed facility, tower, antennas, equipment compound, structures and associated equipment including height, design, features, access road and power lines, if any, ii. Information which demonstrates compliance with the applicable structural standards of EIA/TIA RS 222, iii. A description of the tower's capacity, including the number and types of antennas it can accommodate. The report shall indicate the power and frequency of all transmissions to be broadcasted from the facility. In the case of an antenna mounted on an existing structure, the report shall indicate: the existing structure's suitability to accept the antenna, and the proposed method of affixing the antenna to the structure; complete details and scaled drawings of all fixtures and couplings, and the precise point of attachment shall be indicated. Where a roof mount extends above the roof, the applicant shall demonstrate every effort has been made to conceal the mount within or behind existing architectural features to limit visibility from public streets and adjoining properties. Side mounts shall blend with the existing architecture and if over five square feet shall be painted or shielded with material consistent with the design features and materials of the building, iv. A map (1:100,000 scale) showing the extent of planned coverage for the PWS within the city and the location and service of applicant-operated facilities, v. Plan and elevation drawings showing the proposed tower, antennas and their associated equipment. The plan shall have a scale no smaller than one inch equals forty (40) feet, vi. A topographic profile showing the proposed tower, antennas, the equipment compound and all associated equipment. The topography shall be drawn with a minimum of two-foot contour intervals; b. The applicant shall submit an environmental impact statement (EIS) which shall address a description of the environmental characteristics of the facility site, archaeological sites and any historically designated areas of the site, any impacts to these and a mitigation plan; c. The applicant shall submit a visual environmental assessment form (Visual EAF) which shall include: i. A sight line representation shall be shown from any public street within one hundred (100) feet and the closest facade of each building (viewpoint) within one hundred (100) feet to the highest point (visible point) of the regulated facility. Each sight line shall be depicted in profile, drawn at one inch equals forty (40) feet. The profiles shall show existing intervening trees and buildings, ii. A plan map of a circle of one mile radius from the facility site on which any visibility of the proposed tower from a public way shall be indicated, iii. An architectural rendering of the view of the tower from adjoining properties and streets, iv. The applicant shall submit photographs of: (A) Existing condition photographs in which each sight line shall be illustrated by an eight-inch by ten (10) inch color photograph of what can currently be seen from any public street within one hundred (100) feet, and at a minimum of eight cardinal radials to the extent that access as needed is granted by property owners, (B) Proposed after-condition photographs in which each existing condition photograph shows the proposed facility superimposed on it to scale, v. Applicant shall provide a view shed analysis also showing these photograph locations; d. A landscape plan addressing the site plan details required by Section 17.56.080(C) of this chapter; e. A Site Selection Report. i. A site selection report shall inventory existing facilities, towers and antenna sites within a reasonable distance (at least one mile in all directions of all wireless telecommunications carriers within and outside the city of Elizabeth) from the proposed site outlining opportunities for shared use as an alternative to the proposed use. The applicant must demonstrate that the proposed tower, facility or antenna cannot be accommodated on an existing tower, building or structure as enumerated in Sections 17.56.030 and 17.56.040(A) and (B) of this chapter due to one or more of the following reasons: (A) Written confirmation of the unwillingness of the owner to entertain a facility modification or PWS proposal, (B) The applicant's proposed equipment would exceed the structural capacity of existing and approved tower and facilities considering existing and planned uses for the facilities, (C) The proposed equipment would cause radio frequency interference, which cannot be reasonably prevented, with other existing or planned equipment of the facility, (D) Existing or approved towers or facilities do not have space on which applicant's proposed equipment can be placed so it can function effectively and reasonably, (E) Other reasons which make it impracticable to place the equipment proposed by the applicant on an existing approved tower or facilities. ii. A statement containing a description of the siting criteria and the process by which other possible sites were considered and eliminated, including but not limited to: real estate search areas, distances and bearings to other system sites, acceptable radio frequency signal strength levels and/or microwave interconnection path requirements. The applicant shall support this statement with the submission of a study comparing all potential host sites within an approximate two-mile radius of the subject site (areas where personal wireless service facilities are prohibited need not be considered). This study should include a description of the surrounding sites, and a discussion of the ability or inability to host a facility. Reasons for excluding a site from consideration may include, without limitation: (A) The written confirmation of the unwillingness of the owner to entertain a facility, (B) Topographic limitations of the site, (C) Adjacent impediments that would obstruct adequate wireless transmissions, (D) Physical site constraints that would preclude the construction of a facility, and (E) Technical limitations of the proposed wireless system; f. A report on compliance with the latest version of the ANSI standards and analyzed according to the requirements of the FCC Bulletin O.E.T. 65 describing the impact on human health, if any, prepared by a radio frequency engineer. The report shall indicate compliance with all applicable FCC regulations and guidelines; g. A written irrevocable commitment to rent or lease available space for co-location on the tower at fair market prices and terms, without discrimination to other carriers; h. The reviewing agency may require a balloon test which shall be held by the applicant at least fourteen (14) days prior to the public hearing with a notice to the public in a local newspaper of general circulation of the location, time and date. Notice to the public shall be by the applicant at least seven to fourteen (14) days in advance of the first test date and shall list an alternative date and time in case of poor visibility on the initial date. At the test, a three-foot diameter brightly-colored balloon shall be raised to the height of the proposed tower and shall remain in place as long as practical but not less than four consecutive hours sometime between 9:00 a.m. and 5:00 p.m. of the dates chosen. 2. Existing Towers and Facilities. Where a new PWS or antenna is proposed to be constructed or located on an existing tower structure or building as described in Section 17.56.030 as first priority and Section 17.56.060 of this chapter, the following shall be submitted and considered in addition to the requirements of Section 17.56.050 of this chapter and any city-applicable site plan requirements: a. A description of the proposed antennas and associated equipment; b. A map (1:100,000 scale) showing the extent of planned coverage for the PWS within the borough and the location and service of applicant-operated facilities; c. Plan and elevation drawings at a scale of one inch equals forty (40) feet showing the proposed antennas and their associated equipment; d. A report on compliance with the latest version of the ANSI standard and analyzed according to the requirements of the FCC Bulletin O.E.T. 65 describing the impact on human health, if any, prepared by a radio frequency engineer. The report shall indicate compliance with all applicable FCC regulations and guidelines; e. A structural analysis of the existing tower with the antennas and associated equipment prepared and signed by a licensed engineer demonstrating compliance with EIS/TIA EIA RS 222; f. If the construction or placement constitutes an expansion of a legally nonconforming facility or tower, identification of other facilities or towers where the equipment or antenna could be located and the reason this location is superior to other locations is required.
(Ord. 3678 § 1 (part), 2005: prior code § 40-207)
Ask a question about Elizabeth law
Corpus searches the Elizabeth sections it holds and shows the ones that match, with their citations. Free, no sign-in.