§ 254-23 — Electrical facilities
Code of the City of Jersey City, New Jersey (Supp. No. 53: covering ordinances through 26-016, passed February 11, 2026) · Jersey City Code § 254-23
Corpus is an independent public-information project, not the official City of Jersey City website. Stable reference: corpuslaw.us/code/58f39c63-f7a6-4be5-927c-07d64bf3ccd7
§ 254-23. - Electrical facilities.
A. Residential. (1) Electrical service generally. Every dwelling, dwelling unit and rooming unit shall be properly connected to and be provided with electric power through safely insulated conduits conforming to Chapter 131, Uniform Construction Codes. [4] (2) Circuits. Overloading of circuits is prohibited. Where such violation exists, the owner shall be required either to install a line or lines of sufficient capacity to absorb the peak seasonal load to which such line or lines are subjected or to install a fusestat or fusestats that will limit the use of such existing line or lines to the properly rated capacity. (3) Fuses and protective devices. Maximum fuse sizes consistent with safety shall be posted conspicuously on the inside cover of all fuse boxes and no fuse shall be installed there in excess of the stated maximum. Fusestats shall be installed in any fuse box located within a dwelling unit or rooming unit in the exclusive possession of occupants other than the owner. (4) Outlets and fixtures. Every electrical outlet and fixture shall be properly installed and maintained in good safe condition so as not to cause a fire or electrical shock hazard and shall be properly connected to the source of power. No ceiling or wall fixtures shall be used to supply power to equipment other than that for which these are designed. (5) Wiring. Insulation shall be provided for all wiring and cables and shall be kept in good repair. No loose or temporary wiring shall be used except extension cords six (6) feet in length or less that are in good and safe condition, run directly from portable fixtures or appliances to convenience outlets, and do not lie under rugs or other floor coverings nor extend through doorways, transoms, holes or other openings through structural elements. (6) Electrical outlets in habitable rooms. There shall be at least two (2) permanently installed remote wall-type double-electric convenience outlets in every habitable room. In lieu of this, each room must contain at least one (1) permanently installed wall-type double-electric convenience outlet and one (1) overhead light fixture. (7) Light fixtures for bathrooms and water closet compartments. Every bathroom and water closet compartment shall be provided with at least one (1) permanently installed ceiling or wall-type electric light fixture and a switch and wall plate so located that there is no danger of short-circuiting from water from other bathroom or water closet facilities or from splashing of water. B. Nonresidential. (1) Electrical service generally. Electrical power through safely insulated conduits conforming to Chapter 131, Uniform Construction Codes, shall be supplied to nonresidential buildings regularly utilized for business, commercial, governmental, industrial or institutional work and activities and to garages designed for use by four (4) or more vehicles. [5] (2) Lighting of bathrooms and water closet compartments. Every bathroom and water closet compartment shall be provided with permanently installed, artificial ceiling or wall-type electric lighting fixtures with a switch and wall plate so located and maintained that there is no danger of short-circuiting from water from other bathroom facilities or from splashing of water. (3) Lighting of common spaces other than habitable rooms, bathrooms and water closet compartments. (a) All nonresidential buildings, including the garages required to have electric service under Subsection B(1) of this section, also shall be provided with permanently installed, artificial lighting fixtures. All such fixtures shall be operable from a switch located near the point of ingress to the interior of the space lighted. All portions of the premises which are utilized regularly for work and activities shall be illuminated by at least five (5) footcandles, that is five (5) lumens or one (1) watt per square foot of floor area measured in the darkest portions thereof. All portions of the premises other than common means of passage that are used occasionally and incidentally by occupants of the premises shall be illuminated by at least three (3) footcandles; that is, three (3) lumens or one-half (½) watt per square foot of floor area measured in the darkest portions thereof. (b) Lighting of hallways, stairways, landings and other spaces used by occupants in common as a normal means of passage shall be sufficient to provide at least five (5) footcandles; that is, five (5) lumens or one (1) watt per square foot of floor area measured in the darkest portion. Light switches for stairs and hallways shall be readily accessible to occupants using the same except where janitorial service is provided and the artificial lighting for hallways and common areaways is supplied from a master control switch. (4) Overloading of circuits is prohibited. Where such a violation exists, the owner shall be required either to install a line or lines of sufficient capacity to absorb the peak seasonal load to which such line or lines are subjected or to install a fusestat or fusestats that will limit the use of such existing line or lines to their proper, rated capacity. (5) Fuses and protective devices. Maximum fuse sizes consistent with safety shall be posted conspicuously on the inside cover of all fuse boxes and no fuse shall be installed therein in excess of the stated maximum. Fusestats shall be installed in any fuse box located in any part of the premises which is in the exclusive possession of occupants other than the owner. (6) Outlets and fixtures. Every electrical outlet and fixture shall be properly installed and maintained in good and safe condition so as not to cause a fire or electrical shock hazard and shall be properly connected to the source of power. No ceiling or wall fixture shall be used to supply power to equipment other than that for which these are designed. (7) Wiring. Insulation shall be provided for all wiring and cables and shall be kept in good repair. No loose or temporary wiring shall be used except extension cords six (6) feet in length or less that are in good and safe condition, run directly from portable fixtures or appliances to convenience outlets, and do not lie under rugs or other floor coverings, nor extend through doorways, transoms, holes or other openings through structural elements.
Ask a question about Jersey City law
Corpus searches the Jersey City sections it holds and shows the ones that match, with their citations. Free, no sign-in.