§ 11:1-10: TECHNICAL AMENDMENTS TO THE NEW JERSEY UNIFORM FIRE CODE.
a. Sections F316.2.1, F-316.2.2 and F-316.2.3 of the New Jersey Uniform Fire Code are amended as follows: F-316.2.1 Sales of Portable Kerosene Appliances: It shall be unlawful in the City of Newark for any person to offer for sale, expose for sale, sell, possess or use any portable gasoline, kerosene, or other portable gasoline, kerosene, or other portable appliances using liquid fuels for cooking or heating. F-316.2.2 Sale of Fixed Kerosene Appliances: It shall be unlawful in the City of Newark to offer for sale, expose for sale, sell, possess or use any fixed kerosene or other liquid fuel burning stove or heater, or appliances, for cooking or heating purposes, unless one such stove, heater or appliance has been listed by the Underwriters' Laboratories or is one of equal kind and structure approved by the Fire Director or his designee. F-316.2.3 Containers for Kerosene: Containers for kerosene shall be either of a plastic or metal construction with fill and vent openings. The container shall be blue with white lettering. The word "kerosene" shall be displayed around the perimeter of the container. b. Sections F-412.0, F-412.1 and F-412.2 are hereby added to the Fire Code as follows: F-412.0 Residential Smoke Detectors. F-412.1 General: All existing residential uses, as defined by the building code listed in Appendix A, shall be provided with a minimum of one approved smoke detector in the sleeping area, guest room or suite of a hotel, motel, lodging house, boarding house or residential dwelling unit. Each detector shall be installed in accordance with NFiPA 72E or NFiPA 74 listed in Appendix A. When actuated, the smoke detector shall provide an alarm suitable to warn the occupants within the individual room or unit. F-412.2 Tampering: Any tampering or interfering with the effectiveness of a smoke detector shall be in violation of this code.
[ Ord. 6 S+FD, 8-7-1985 ]
Ask a question about Newark law
Corpus searches the Newark sections it holds and shows the ones that match, with their citations. Free, no sign-in.