16:22-7 — REQUIREMENTS FOR INSPECTIONS AND TESTING
Code of the City of Newark, New Jersey (Newark City Code and Charter current through the 2026-09-23 codification (eCode360 publication NE4043, scraped 2026-11-17)) · Newark City Code § 16:22-7
Corpus is an independent public-information project, not the official City of Newark website. Stable reference: corpuslaw.us/code/efb7dd72-c0b5-44ef-b326-e2f6ba212c09
§ 16:22-7: REQUIREMENTS FOR INSPECTIONS AND TESTING.
a. An owner or operator of a cooling towers, with the exception of cooling towers whose use has been permanently discontinued and for which a written notice of such discontinuation has been sent to the Department, shall be inspected and tested a minimum every three months during periods of the year such cooling towers are in use. b. Each inspection shall include an evaluation of the cooling tower and associated equipment for the presence of organic material, biofilm, algae and other visible contaminants. c. Each inspection shall include a test for the presence of microbes in the water of the cooling tower. The Department shall by rule establish: 1. The targets and acceptable methods of microbial testing and laboratory analysis; and 2. The levels of microbes in cooling towers that are indicative of a maintenance deficiency requiring mitigation, including but not limited to maintenance to prevent potential health risks; and 3. The levels of microbes in cooling towers that present a serious health threat and require immediate action and reporting. d. Where the results of any such test indicate levels of microbes that are indicative of a maintenance deficiency requiring mitigation, including but not limited to maintenance to prevent potential threat to the public's safety, health, and welfare, the owner of the building that has such cooling tower shall, within 48 hours after such owner knows or reasonably should know of such results, clean and disinfect the cooling tower in accordance with the industry standard. e. Where the results of any such test indicate levels of microbes that present a threat to the public health, safety, and welfare, the owner of the building that has such cooling tower shall, within 24 hours after such owner knows or reasonably should know of such results: notify the Department by written notice; and clean and disinfect the cooling tower, including an additional application of biocide, in accordance with industry standards.
[ Ord. 6 PSF-D, 12-2-2015 § 1.7]
Ask a question about Newark law
Corpus searches the Newark sections it holds and shows the ones that match, with their citations. Free, no sign-in.