18:3-1.50 — Natural Ventilation
Code of the City of Newark, New Jersey (Newark City Code and Charter current through the 2026-09-23 codification (eCode360 publication NE4043, scraped 2026-11-17)) · Newark City Code § 18:3-1.50
Corpus is an independent public-information project, not the official City of Newark website. Stable reference: corpuslaw.us/code/f4ac0396-e126-419b-a812-b838c487792c
§ 18:3-1.50: Natural Ventilation.
Except as may otherwise be provided by Section 18:3-1.51 of this Article: a. Every habitable room shall be provided with a window or skylight which opens directly to the outer air. The total area of such window or skylight shall not be less than 10% of the floor area of such room. All windows and skylights shall be enclosed with glass and shall be provided with suitable devices to allow ventilation. Such windows or skylights shall be made to open readily to the extent of 5% of the floor area or a minimum of 10 square feet, whichever is greater. b. Every bathroom and water closet compartment shall be provided with a sash window of not less than three square feet in area which opens directly to the outer air. Such window shall be enclosed in glass and shall be provided with a suitable device to open readily to allow ventilation. CROSS REFERENCE: For housing and zoning regulations (Certificate of Code Compliance) see Section 18:6-7.1.
[R.O. 1966 § 15:4-22]