a. General Installation Requirements. 1. Window guards shall be installed in accordance with all applicable requirements of the State Uniform Construction Code, N.J.A.C. 5:23, and with manufacturer's instructions. 2. Any window guard installed on an emergency egress window shall be releasable or removable from the inside without use of a key, tool, or excessive force. An emergency egress window is any window in a sleeping room located on the second or third floor, other than a window providing access to a fire escape. 3. Any window guard installed on a window that is not an emergency egress window, including any window in a unit located above the third floor and any window in a room on the second or third floor that is not a sleeping room, shall be designed, constructed and installed so that it cannot deliberately or through accident, ignorance or inadvertence, be removed, opened or dislodged without the use of a key or tool. b. Specifications for Window Guards. 1. Window guards shall be so constructed as to reject the passage of a solid four (4) inch sphere at every space and interval. 2. Window guards shall bear a one hundred fifty (150) pound load at a center span when extended to maximum width. 3. Window guards shall be constructed of metal or of other material of comparable strength and durability. In order to avoid obstruction of light and air, the diameter or width of metal rods used in window guards shall not exceed one-half (1/2) inch. 4. Window guards shall be designed, constructed and installed so as to serve their intended protective purpose without any risk of collapse, breakage, spreading of the bars or other malfunction. 5. In a room, window guards shall be of at least a height sufficient to allow a total openable window area, for all windows in the room, of not less than four (4%) percent of the floor area of the room. In a public hallway, window guards shall protect the full openable area of each window. 6. Window guards shall be securely fastened in order to bear the required load. 7. All window guards shall be so designed and installed as to prevent the lower window from being raised four (4) inches or more above the lowest section of the top horizontal bar of the window guard. Where necessary, rigid metal stops shall be installed securely in the upper tracks of each side of the bottom window. 8. Screws used to mount window guards and stopping devices should be: (a) Minimum Size No. 10 and long enough to penetrate one (1) inch into a wooden window frame; or (b) Of an adequate type, size, and length to be securely fastened to a metal window frame. 9. The coating of window guards shall be unleaded. 10. Window guards shall be installed only in sound (non-rotting) mountings or tracks. 11. Window guards installed prior to the passage of this section shall be accepted as being in conformity with the specifications contained in this paragraph b above, if they were installed in accordance with paragraph a above. c. Additional Specifications for Window Guards Other than Double Hung Windows. 1. Window guards intended for casements, sliders and other types or combinations of windows in which the height of the openings is not subject to limitation, shall be of such size as to fill the entire aperture, and shall reject passage of a solid four (4) inch sphere at every space or interval. 2. Except as otherwise provided in paragraph 3 below, sliding windows and vertical pivoting windows may be equipped with stopping devices in place of window guards as follows: (a) For sliding windows, solid metal blocks, measuring at least one-half (1/2) the depth of the window track and one-half (1/2) the width, shall be securely fastened into the bottom and upper window tracks to prevent the window from opening four (4) inches or more. (b) For vertical pivoting windows, metal stopping devices shall be securely fastened to the upper and lower window frames so as to prevent the window from pivoting open four (4) inches or more. The height of the stopping devices shall extend not less than one (1) inch nor more than two (2) inches beyond the window frame as needed to stop the window. The protruding edge of the stopping device shall be smooth and rounded. 3. Use of such stopping devices in lieu of window guards shall be allowed within dwelling units only where they do not preclude meeting the requirement, as per N.J.A.C. 5:10-16.2, that the total openable window and/or openable skylight area in each room be equal to at least four (4%) percent of the floor area of the room.

[Added 8-2-2023 by Ord. No. 6PSF-J , 08-02-2023 ]

Ask a question about Newark law

Corpus searches the Newark sections it holds and shows the ones that match, with their citations. Free, no sign-in.