For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

12:4-6.2 — Nonresidential Construction

Code of the City of Newark, New Jersey (Newark City Code and Charter current through the 2026-09-23 codification (eCode360 publication NE4043, scraped 2026-11-17)) · Newark City Code § 12:4-6.2

Corpus is an independent public-information project, not the official City of Newark website. Stable reference: corpuslaw.us/code/c01ca217-0c26-4c9e-8b8f-76c348c80931

§ 12:4-6.2: Nonresidential Construction.

In an Area of Special Flood Hazard, all new construction and substantial improvement of any commercial, industrial or other nonresidential structure, located in an A or AE zone (for Coastal A Zone construction see Section 12:4-9, Coastal High Hazard Area and Coastal A Zone), shall have the lowest floor, including basement, together with attendant utility and sanitary facilities as well as all electrical, heating, ventilating, air-conditioning and other service equipment either: a. Elevated at or above the more restrictive of the following: 1. For A or AE zones: (a) Base flood elevation (published FIS/FIRM) plus one foot; (b) The best available flood hazard data elevation plus one foot; (c) As required by ASCE/SEI 24-14, Table 2-1; or (d) As required by N.J.A.C. 7:13-3. 2. For AO or AH zones on the municipality's FIRM to elevate above the depth number specified in feet plus one foot, above the highest adjacent grade (at least three feet if no depth number is specified). And, require adequate drainage paths around structures on slopes to guide floodwaters around and away from proposed structures; 3. Record the method and elevation used above and the Best Available Flood Hazard Design Data elevation, date and revision in the local Development Permit. Or b. Be floodproofed so that below: 1. For A or AE zones apply the more restrictive of the following: (a) Base flood elevation (published FIS/FIRM) plus one foot; (b) The best available flood hazard data elevation plus one foot; (c) As required by ASCE/SEI 24-14. Table 6-1; or (d) As required by N.J.A.C.7:13-3. (e) AO or AH zone elevation based upon the highest adjacent grade, plus the depth number specified in feet, plus one foot (at least three feet if no depth number is specified). And, require adequate drainage paths around structures on slopes to guide floodwaters around and away from proposed structures. 2. Be floodproofed so that below the base flood level the structure is watertight with walls substantially impermeable to the passage of water; 3. Have structural components capable of resisting hydrostatic and hydrodynamic loads and effects of buoyancy; and 4. Be certified by a registered professional engineer or architect that the design and methods of construction are in accordance with accepted standards of practice for meeting the applicable provisions of this subsection. Such certification shall be provided to the official as set forth in Section 12:3-5. 5. Record the method and elevation used above and, the Best Available Flood Hazard Design Data elevation, date and revision in the local Development Permit.

[Amended 3-24-2020 by Ord. No. 6PSF-A , 03-24-2020 ]

Ask a question about Newark law

Corpus searches the Newark sections it holds and shows the ones that match, with their citations. Free, no sign-in.