§ 12:5-1: ELEVATION.
All new construction and substantial improvements shall be elevated on piling or columns so that: a. The bottom of the lowest horizontal structural member of the lowest floor (excluding the piling or columns) (together with the attendant utilities and sanitary facilities as well as all electrical, heating, ventilating, air-conditioning and other service equipment) is elevated to or above the more restrictive: 1. Base flood elevation (published FIS/FIRM) plus one foot; 2. The best available flood hazard data elevation plus one foot; 3. As required by ASCE/SEI 24-14, Table 2-1; or 4. As required by N.J.A.C. 7:13-3. b. Record the method and elevation used above and, the Best Available Flood Hazard Design Data elevation, date and revision in the local Development Permit; and c. With all space below the lowest floor's supporting member open so as not to impede the flow of water, except for breakaway walls as provided or in Section 12:5-4.
[Amended 3-24-2020 by Ord. No. 6PSF-A , 03-24-2020 ]