In setting or resetting a meter, the requirements are as follows: a. The meter shall be set so that the dial shall be faced upward and set horizontal and not more than three feet above the floor. A connection shall be made by meter couplings or companion flanges (depending on the size of the meter) or both the inlet and outlet end of the meter. Meter couplings and/or flanges shall be provided and installed by the licensed plumber performing the work necessary to the setting of the meter. All connections shall be compatible with the meter to be set. Both meter couplings and flanges shall be bored for sealing with holes not less than three 3/32 of an inch in diameter. A valve shall be set on the inlet and outlet side of all meters, regardless of size, and when a current type meter is set, a straight section of pipe of a length at least eight times the nominal size of the diameter of the meter shall be installed immediately before the inlet, between the controlling valve and the meter, and no fittings of any kind will be permitted in this straight section of pipe. An approved backflow preventer shall be installed at the outlet side of any meter. The remote reading device provided with the meter shall be installed on the exterior front/side of the building being metered. b. On 1 1/2 inch and two inch meters, a full sized test fee shall be placed on the outlet between the meter and the outlet valve with a short nipple in the tee and a full size valve on the nipple. On meters three inches and larger a test tee with a two-inch opening shall be placed on the outlet between the meter and outlet valve, a short nipple in the tee and a two-inch valve on the nipple. No connection shall be made to a test tee. c. Before setting three inch and larger meters, the plumber shall file in duplicate, for approval of the Director of Water and Sewer Utilities or his authorized representative, a plan or sketch showing the proposed installation. Such plan or sketch shall indicate the location of the service main control valve inside the building, the distance of the meter from the point of entry of the service, height from the floor, size and type of meter and the approximate date of setting. In all cases the meter location and setting shall be to the satisfaction of the Director of Water and Sewer Utilities or his authorized representative. d. Where two inch and larger meters are installed and no plumbing fixtures or other facilities are available for disposal of discharge water from a standard test meter, provisions shall be made for disposal of such water through piping installed for such purpose from a point near the meter to the outside of the building. An additional test tee, nipple and valve shall be inserted in the service line, on the outlet side of the meter outlet valve, and by-pass connection, to discharge test water where no other practical method of discharging such water can be used. e. Non-meter by-passes are not permitted. All water consumption must be registered by a water meter. f. All connection pipes, fittings, valves, etc. on meter settings shall be of nonferrous, lead-free materials, as approved by the Director. g. Electric "ground connections" shall not be made to water pipes. The Director may grant exceptions where such connections are made well ahead of the meter — between the point of entry of the service connection and the inlet valve. Meters shall not be set near electrical conductors or other electrical equipment or in close proximity to any machine that normally might cause injury to Department employees. h. A meter shall be restricted to a size that will ensure accurate registration on the basis of consumption and occupancy of the premises or portion of the premises metered. The meter in no case may be larger than the tap or connection to the City main except as agreed upon by the Director and the customer. i. Where accurate registration cannot be obtained, owing to low usage because of insufficient flow to operate the meter, the Department may, at its discretion, issue a smaller meter. When such reduction of the meter size is effected, the plumber that installs the meter shall ensure that the piping of the meter setting from the inlet valve to the outlet valve is the same size as the meter. j. As a condition of service, the Department reserves the right to inspect, read, remove, repair, calibrate and reinstall any meter during normal working hours or at other times by mutual arrangement with the property owner. The cost of such service is to be charged to the customer. k. The Department may require a meter to be removed for testing by the Department and later reinstalled by a licensed plumber, at the customer's expense, when it is determined that such meter is not properly registering, requires repairs, is installed at variance with this chapter, and/or is so placed as to risk injuries to Department employees in the normal performance of their duties. l. No meter shall be set or reset in a pit without written permission of the Department and only under exceptional conditions where the meter cannot be located within the building and then only when a remote reading device is installed. m. No seal placed by the Department for the protection of any meter, valve, fitting or other water connection shall be tampered with or defaced. No seal shall be broken except on written authorization of the Department. Where the seal is broken, the Department reserves the right to order the meter removed for testing at the expense of the customer. Breaking or defacing the seal of a water meter is a violation of Section 20:2-15(l) and carries a minimum fine of $200. n. The owner or customer shall be responsible for safeguarding the meter and seal, and, if required by the Department, the owner or customer shall properly box and protect the meter and seal. Meters shall be maintained in good working order at all times. o. If a meter shall have been removed without authority of the Department, it shall not be reinstalled until tested by the Department at the cost of the customer. p. Meter repairs, when possible, may be made by the Department on the premises. q. Private meters shall not be permitted for the purpose of measuring water flow. All water consumption in and for the City of Newark shall be measured by City-issued water meters and will be billed for by the Department. r. In any premises where water is obtained through more than one meter, and where tests indicate that accurate registration is not being obtained by reason of divided delivery of water through more than one meter, the Department reserves the right to shut off and seal one or more of the meters to ensure accuracy of registration. s. The Department reserves the right to refuse to permit any meter installation that does not conform to this chapter or is in an unsanitary or dangerous location. The Department may refuse to supply water under such conditions. t. Meters specially adapted for use on fire or automatic sprinkler service, where it is desired to measure accurately all rates of flow and, in case of fire, to automatically deliver and measure large volumes of water without obstruction, shall be installed, at the customer's expense, when required, on fire lines service connections. They shall be of a type approved by the Department and the Factory Mutual Laboratories and the Underwriters' Laboratories, Inc. u. The right is reserved by the Department to require the customer, at the customer's expense, on any or all fire service connections, installation of an approved type detector check valve to guard against leakage or possible misuse of water provided for fire protection purposes. This "detector" device shall be one approved by the Department and by the Factory Mutual Laboratories and the Underwriters' Laboratories, Inc. v. The use of water through meters approved for a fire line only is prohibited for any other use other than fire protection. w. From time to time, as directed by the Director or his authorized representative, meters shall be tested in service on the premises. When such test, or any other inspection shows the meter to be defective, it shall be ordered for repair and testing before reinstallation. All costs in connection with this work shall be at the expense of the owner.

[R.O. 1966 § 25:4-76; Ord. 6 S+FH, 7-13-2005 § 1]

Ask a question about Newark law

Corpus searches the Newark sections it holds and shows the ones that match, with their citations. Free, no sign-in.