41:9-10 — Signage Design and Measurement Requirements
Code of the City of Newark, New Jersey (Newark City Code and Charter current through the 2026-09-23 codification (eCode360 publication NE4043, scraped 2026-11-17)) · Newark City Code § 41:9-10
Corpus is an independent public-information project, not the official City of Newark website. Stable reference: corpuslaw.us/code/20e7d196-b869-432c-8bb3-afa5084fab0a
§ 41:9-10: Signage Design and Measurement Requirements.
1. The following signs and standards and conditions that govern such signs are set forth in Table 9-1. All other signs are expressly prohibited unless otherwise regulated in this Chapter. The following design standards shall apply: a. Signs shall be in harmony and consistent with the architecture of the building and related to the features of the building in terms of location, scale, color, lettering, materials, texture and depth. Signs shall not be dominant but shall be proportionate and shall complement the building, existing signs and surroundings. b. There shall be consistent sign design throughout a particular project. The design elements include style of lettering, construction materials, size and illumination. c. Building signs shall not obscure, conflict with, or cover any architectural element and must be aligned with major building elements such as windows, trim and structure lines. d. No sign shall extend or project above the highest elevation of the wall to which it is attached or above the lowest part of the roofline of the building, whichever is less. e. Signs and sign structures of all types shall be located to allow a clear, unobstructed line of sight for 300 feet from the stop line of any intersection of streets and/or driveways, traffic signal or traffic directional sign in the intersection. f. The width of signs mounted on the ground floor for any nonresidential or non- industrial use may be 100% of the width of the portion of the wall area dedicated to the applicable use if that width is less than 30 feet, or 75% if the relevant width is 30 feet or greater. 2. All signs shall comply with the standards enumerated in Table 9-1 below: Table 9-1: Signage Design And Measurement Requirements Signage Type | Maximum Total Area (SF) | Maximum Number | Maximum Height of Sign(feet) | Other Requirements SINGLE-, TWO-, THREE-, AND FOUR-FAMILY DWELLING Wall Sign | 1 | 1 | Not to be located above the first floor on the building. | Home occupation or profession only. (Address numbers are exempt.) TOWN HOUSES AND ROW HOUSES; LOW-, MID- AND HIGH-RISE RESIDENTIAL Wall Sign | 20 | 1 per street frontage for complex | Not to be located above the first floor on the building. | Building or complex Identification only - home occupation signs are not permitted for multi-family developments. OR Monument | 25 | 1 per street frontage | 5 feet including base | Where permitted, monument signs shall be set back at least 5 feet from all property lines and 5 feet from all structures. MIXED-USE BUILDING WITH COMMERCIAL AND RESIDENTIAL USES Wall Sign | 10% of the wall area associated with the tenant space but no greater than 50 square feet per sign. | Commercial: 1 per commercial tenant, per frontage occupied by the tenant | Not to be located more than 4 feet above the top of the door, window, or lintel line, whichever is tallest. Residential: 1 per frontage Projecting | 6 | 1 per commercial tenant per frontage occupied by the tenant | n/a | May project a maximum of 4 feet from the building. Minimum distance between the ground and the bottom of the sign is 8 feet; Sign must be hung by brackets at right angles to the facade Window | No more than 10% of glazed area for signs. | n/a | n/a Awnings | To be used in lieu of wall signs, subject to same conditions | n/a | n/a | Awnings, which are not internally lit, may be used to display signage in lieu of a wall sign. However, an awning with no signage but for the name, address and phone number on the fringe of the awning with lettering no greater than 8 inches high may be used in addition to a wall sign. A minimum letter height of 12 inches shall be used Window Sign (above ground level) | 25% of the total glazed area of the windows applicable to the use. | 1 per street frontage | Signs may be located in the windows of the second or third levels of a building. | A sign for a commercial use above first level may be installed at the second or third level DETACHED COMMERCIAL/SCHOOLS/COMMUNITY CENTERS/PLACES OF WORSHIP/HOSPITAL OR MEDICAL INSTITUTIONS Wall Sign | 10% of the wall area associated with the tenant space but no greater than 70 square feet per sign. | 1 per tenant, per frontage occupied by the tenant | Not to be located more than 4 feet above the top of the door, window, or lintel line, whichever is tallest. For a single tenant building, 10% of the wall area but no greater than 100 square feet per sign. Projecting | 6 | 1 per commercial tenant, per frontage occupied by the tenant | n/a | May project a maximum of 4 feet from the building. Minimum distance between the ground and the bottom of the sign is 8 feet; Sign must be hung by brackets at right angles to the facade Window | No more than 10% of glazed area for signs | n/a | n/a Awnings | To be used in lieu of wall signs, subject to same conditions. | n/a | n/a | Awnings, which are not internally lit, may be used to display signage in lieu of a wall sign. However, an awning with no signage but for the name, address and phone number on the fringe of the awning with lettering no greater than 8 inches high may be used in addition to a wall sign Monument Sign | 25 square feet | 1 per street frontage | 5 ft. including base | Monument signs shall be set back at least 5 feet from all property lines and 5 feet from all structures. A minimum letter height of 12 inches shall be used FUNERAL HOME OR MORTUARY Wall Sign | 10 | 1 per street frontage | Not to be located more than 4 feet above the top of the door, window, or lintel line, whichever is tallest. Monument Sign | 25 | 1 | 5 ft. including base | Monument signs shall be set back at least 5 feet from all property lines and 5 feet from all structures. A minimum letter height of 12 inches shall be used AUTOMOTIVE SERVICE; AUTOMOTIVE SALES AND REPAIR Wall Sign | 10% of the wall area but no greater than 50 square feet. | 1 per street frontage | Not to be located more than 4 feet above the top of the door, window, or lintel line, whichever is tallest. Monument | 25 | 1 per street frontage | 5 | Monument signs shall be set back at least 5 feet from all property lines and 5 feet from all structures. SELF STORAGE Wall Sign | 10% of the wall area but no greater than 100 square feet. | 1 per street frontage | n/a Monument | 25 | 1 per street frontage | n/a | Monument signs shall be set back at least 5 feet from all property lines and 5 feet from all structures. ALL OTHER INDUSTRIAL USES Wall Sign | 10% of the wall area but no greater than 100 square feet. | 1 per street frontage | n/a Monument | 25 | 1 per street frontage | 5 | Monument signs shall be set back at least 5 feet from all property lines and 5 feet from all structures. 3. Other signs not listed in Table 9-1. a. Building types or uses not listed in Table 9-1 shall comply with the signage standards for the most similar or appropriate building or use as determined by the Zoning Officer. b. Office buildings of 12 stories or more with signs indicating the address or owning company's name or trademark image may be placed below the parapet line and above the top floor row of windows and shall be no more than 50% of the building width. Such signs shall be limited to business identification for the principal tenant or owner, who must occupy at least 40% of the building's total floor area. Such signs shall be limited to one tenant/owner per building and one sign per building elevation. Such signs shall be prohibited in the Downtown Business District on buildings under 110 feet in height. Such signs shall be prohibited on key and contributing historic buildings in historic districts as well as on individually landmarked buildings in all districts. Such signage shall not have a negative effect on any historic structure. c. Free-standing signs shall be permitted for detached commercial malls and strip centers with a minimum area of 40,000 square feet and a minimum lot frontage of 200 feet subject to the following: i. Maximum Height - 18 feet. ii. Minimum Setback to any property line - five feet. iii. Maximum Sign Area - 36 square feet.
[Adopted 11-1-2023 by Ord. No. 6PSF-E, 11-01-2023 ]
Ask a question about Newark law
Corpus searches the Newark sections it holds and shows the ones that match, with their citations. Free, no sign-in.
