§ 15.08.020 — Amendments to the BOCA basic property maintenance code/2000
Municipal Code of the City of New Brunswick, New Jersey (Codified through Ordinance No. O-042606, passed April 15, 2026. (Supp. No. 39, Update 2)) · New Brunswick City Code § 15.08.020
Corpus is an independent public-information project, not the official City of New Brunswick website. Stable reference: corpuslaw.us/code/bd082bef-e2b7-4d81-a902-d39a7a6e0992
15.08.020 - Amendments to the BOCA basic property maintenance code/2000.
CHAPTER 1 ADMINISTRATION AND ENFORCEMENT Section PM-100.0 General PM-103.1 GENERAL: The Bureau of Housing Inspections is hereby created and the executive official in charge thereof shall be known as the Chief Housing Official. PM-106.2 PENALTY: Any person, firm, or corporation who shall violate any provisions of this code shall be subject to a fine of not less than $100.00 nor more than $1,000.00, or imprisonment for a term not to exceed 90 days, or both, at the discretion of the court. Each day that a violation continues after due notice has been served, in accordance with the terms and provisions hereof, shall be deemed a separate offense. The penalties pursuant to this section may be collected in a summary proceeding pursuant to N.J.S.A. 2A:58-1 et seq. (Penalty Enforcement Law). PM-106.4 LIEN: In accordance with N.J.S.A. 40:48.2-13 et seq. (2000), any owner or tenant of lands who has neglected or refused to remove or destroy brush, weeds, dead and dying trees, stumps, roots, obnoxious growths, filth, garbage, trash and debris having been duly noticed to remove same, within the manner and time provided shall be charged for the removal or destruction of same by the city, which at its option may remove or destroy the violation in order to preserve the health, safety, general welfare or to eliminate a fire hazard, and said charge shall become a lien upon such lands and shall be added to and become and form part of the taxes next to be assessed and levied upon such lands. Such a lien shall bear interest at the same rate as the taxes and shall be collected and enforced by the tax collector. PM 107.0 Notices and Orders. PM-107.1.1 SUMMONS: At the discretion of the code official, or his designee, no notices, orders, or hearings to abate will be issued when the following violations have occurred: (1) Not providing sufficient heat in any residential building or dwelling unit as required under PM 602. (2) The illegal use of any building or dwelling unit. (3) The conversion of a building or dwelling unit without proper application. (4) The ownership of a building or dwelling unit that has been illegally converted. (5) The occupancy of a building or dwelling unit which is in violation of Chapter 4 of the BOCA Basic Property Maintenance Code. (6) Inadequate exit-way facilities; or (7) Any violation that the code official deems to constitute an imminent hazard to Public Safety or Welfare. PM-107.3 METHOD OF SERVICE. (a) Such notice shall be deemed to be properly served if a copy thereof is: 1. Delivered personally; 2. Sent by certified or first-class mail addressed to the last known address or the address on file in the City's Rent Leveling Office; or 3. If the notice is returned showing that the letter was not delivered, a copy thereof shall be posted in a conspicuous place in or about the structure affected by such notice. (b) Service of such notice in the foregoing manner upon the owner's agent or upon the person responsible for the structure shall constitute service of notice upon the owner. (c) The date of personal service or the third day after mailing shall be considered the date of service. PM-111.1 APPLICATION FOR APPEAL: Any person affected by any notice which has been issued in connection with the enforcement of only sections of P.M. 108, 109, 110, or 308.3 may request and shall be granted a hearing on the matter before the Board of Appeals; provided that such person shall file in the office of the enforcing department a written petition requesting such hearing and containing a statement of the grounds therefor within five (5) days after the day notice was served. PM-111.2 MEMBERSHIP OF THE BOARD: Said board shall consist of three (3) residents of the City appointed by the Mayor, with the advice and consent of Council, including at least one (1) person skilled in real estate sales or development, property management, general contracting or who is a registered architect or engineer with at least three (3) years experience. The person having the qualifications described above shall serve as chairperson. Each member shall have been a resident of the City for at least one (1) year prior to appointment. The Mayor may appoint, with the advice and consent of Council, in addition to the three (3) members above provided for, an alternate member of the board. Such alternate member shall have full power to act when a member of the board is excused because of conflict of interest or when a member is absent. All appointments, other than the alternate member, shall be for a period of two (2) years. Each member shall serve until his or her successor has been appointed and qualified. The Construction Official shall serve or appoint his designee to serve as secretary to the board. DELETE PM-111.2.1, PM-111.2.2, PM-411.5 and PM-111.6. CHAPTER 2 DEFINITIONS PM-202.0 General Definitions DWELLINGS: Alteration: Any change to a building or portion thereof which would change the use or intensity of use of the building. Approved: Approved by the code official. Basement: That portion of a building which is partly or completely below grade. Boarding House: Any building, together with any related structure, accessory building and any land appurtenant thereto, and any part thereof, which contains two or more units of dwelling space arranged or intended for single room occupancy, exclusive of any such unit occupied by an owner or operator, and wherein personal or financial services are provided to the residents, including any residential hotel or congregate living arrangement, but excluding any hotel, motel or established guest house wherein a minimum of eighty-five (85%) percent of the units of dwelling space are offered for limited tenure only, any foster home, any community residence for the developmentally disabled and any community residence for the mentally ill. Dwelling Unit: A single unit of dwelling space providing complete, independent living facilities for one or more persons including permanent provisions for living, sleeping, eating, cooking and sanitation. Family: One or more persons occupying a dwelling unit as a single non-profit housekeeping unit, who are living together as a stable and permanent living unit, being a traditional family unit or the functional equivalency thereof. Floor Area: Any usable space in a dwelling not including closet space, counter tops, etc. Habitable Floor Area: The net floor area in a habitable space excluding encumbrances such as closets, cabinets, columns, etc. Housekeeping Unit: Those occupants of a dwelling unit sharing responsibility for the dwelling as a whole. Illegal Dwelling Unit: A rental unit or rooming unit which is occupied by an excessive number of persons pursuant to State or City law; does not fulfill the State, County, or City requirements for the health, welfare and safety of its occupants; has been created without the requisite building/zoning permits, or is in violation of any State, County or Municipal Law, Ordinance or Regulation. Relocation Costs: Relocation Costs shall include the relocation allocations required to be paid to displaced residential tenants pursuant to State or Federal law. If the tenant does not qualify for said allocations under State or Federal law, then said tenant shall be entitled to receive, from the owner of the premises affected, all actual and reasonable costs associated with relocation. Residential Furniture: Any table, chair, sofa or any other similar object customarily used for the purpose of furnishing the interior of a residential dwelling unit. Rooming House: A Boarding House wherein no personal or financial services are provided to the residents. Rubbish: Combustible and noncombustible waste materials, except garbage; the term shall include the residue from the burning of wood, coal, coke and other combustible materials, paper, rags, cartons, boxes, wood, excelsior, rubber, leather, tree branches, yard trimmings, tin cans, metals, mineral matter, glass, crockery, mattresses, dust and other similar materials. Single Room Occupancy: An arrangement of dwelling space which does not provide a private, secure dwelling space arranged for independent living, which contains both the sanitary and cooking facilities required in a dwelling unit as defined in this code. CHAPTER 3 GENERAL REQUIREMENTS PM-303.4 Weeds. All premises and exterior property shall be maintained free from weeds or, plant growth in excess of eight (8) inches. All noxious weeds shall be prohibited. Weeds shall be defined as all grasses, annual plants and vegetation, other than trees or shrubs provided; however, this term shall not include cultivated flowers and gardens. PM-303.8 Motor Vehicles. No person shall park or store any inoperable, wrecked, or partially dismantled vehicle the wheels of which are not all mounted, or which is in condition of substantial disrepair, nor shall any person park or store any vehicle the tires of which are not inflated or does not have a current affixed and valid automobile license tag. This prohibition, however, shall not apply to any licensed repair facility or similarly enclosed area designed and approved for such purpose. PM-303.9 Storage of Personal Property. Any item that is not customarily used or stored outside or is not made of material that is resistant to damage or deterioration from exposure to the outdoors cannot be placed outside on any property within the City of New Brunswick, unless an area has been proved pursuant to the provisions of Chapter 17 of the New Brunswick Zoning Ordinance. For purposes of this subsection, storage shall be defined as a period longer than ten (10) days. This provision shall apply to items stored on the front yard of the property or on an open porch or carport. Exceptions include motor vehicles on improved surface, lawn furniture and landscaping items, religious artifacts, and holiday decorations. PMC-304.7 Roofs and Drainage. The roof and flashing shall be sound, tight and not have defects that admit rain. Roof drainage shall be adequate to prevent dampness or deterioration in the wall or interior portion of the structure. Drainage from foundation shall be discharged to a storm drain, street, alley, approved watercourse, or at grade. When discharged at grade, leaders and drain pipes must direct storm waters away from the foundation walls of the structure and not to create a nuisance. PM-304.15 Insect Screens. Every door, window and other outside opening utilized or required for ventilation purposes serving any structure containing habitable rooms, food preparation areas, food service areas, or any areas where products to be included or utilized in food for human consumption are processed, manufactured, packaged or stored, shall be supplied with approved tightly fitting screens of not less than 16 mesh per inch and every swinging door shall have a self-closing device in good working condition. Exception: Screen doors shall not be required where other approved means, such as air curtains or insect repellent fans are employed. DELETE: PM-305.4 PM-305.8 DOORS: All interior doors and hardware within any dwelling unit shall be maintained in good condition. Locks on any such door shall be of a passage or privacy type only. PM-308.0 VACANT BUILDINGS. PM-308.1 Findings. The City Council finds that in order to preserve and maintain the appearance and property values of the neighborhoods of the City of New Brunswick and to promote the health, welfare and safety of its citizens, it is necessary to enact standards governing the repair and maintenance of vacant buildings located within the City of New Brunswick. PM-308.2 Definition. An unoccupied or vacant building shall mean any structure intended for residential or commercial use which is not currently occupied or in use. For the purpose of the enforcement of this ordinance a presumption shall exist that a structure vacant for six months or more is not currently occupied or in use. PM-308.3 Safety From Fire. All owners of unoccupied or vacant buildings shall comply with the applicable provisions of the New Jersey Fire Safety Code N.J.A.C. 5:18, et seq. and any local ordinances and the following additional standards for safety from fire: a. No unoccupied or vacant building shall contain any space utilized for the storage of flammable liquids. b. No room within any vacant or unoccupied building shall be used for storage of junk, rubbish or wastes, furniture or building materials not intended to be used in the existing building. c. The early detection and containment of fire being a valid municipal concern, the boarding up of doors and windows shall not be permitted except with the permission of the construction official in emergency situations. When doors and windows are boarded up, they shall be covered with no less than one-half inch exterior plywood or equivalent and be painted the same color as the body of the building. In no case shall boarding up of doors and windows be permitted in excess of six (6) months. Should an owner find it necessary to board up doors and windows in excess of six (6) months, an appeal seeking permission to do so must be made before the expiration of this six (6) month period to the City Housing and Property Maintenance Appeals Board. At the time of appeal all circumstances shall be set forth supporting the owner's request for extension of the board-up. All windows within twenty (20) feet of the ground or which may be readily accessible, may be secured with security screens, bars, and/or grills and the security screens, bars, and/or grills on open windows shall include quick release mechanisms all of which shall be subject to the approval of the Division of Fire Safety of the City of New Brunswick prior to installation. PM-308.4 Safe and Sanitary Maintenance. All unoccupied or vacant buildings shall comply with the following minimum standards for safe and sanitary maintenance: a. Every foundation, exterior wall and exterior roof shall be weather tight, watertight, and rodent proof, shall be kept in sound condition and good repair, and shall be safe to use and capable of supporting the load which normal use may cause to be placed thereon. b. Every yard shall be properly graded so as to prevent the accumulation of stagnant water. c. Every building shall have all utilities, including but not limited to gas, electric, water and sewer turned off and/or disconnected with sewer service to be sealed at the trap of said property. d. The exterior of the premises and the condition of accessory structures shall be maintained so that the appearance of the premises and all buildings thereon shall reflect a level of maintenance in keeping with the standards of the neighborhood, and such that the appearance of the premises and structures shall not constitute a blighting factor for adjoining property owners nor an element leading to the progressive deterioration and downgrading of the neighborhood with the accompanying diminution of property value. PM-308.5 Further Responsibilities of Owners. All owners of unoccupied or vacant buildings shall be required to comply with the following standards: a. Any yard area (front, side and rear) adjacent to an unoccupied or vacant building shall be cleared and maintained free of trash, solid debris, or any other materials that cause litter and accumulates to an unhealthy and blighting proportion. b. Grass, weeds, or vegetation shall not be permitted to grow or remain on the side, front and/or rear yards of any occupied or vacant building so as to exceed a height of eight (8) inches. Any edible vegetation or vegetation planted for some useful or ornamental purpose shall not be governed by this article. c. Unoccupied or vacant buildings including the yard portion of such buildings, shall not be utilized for storage of any materials whether solid or liquid. d. When a vacant dwelling is found to be infested with rats, termites, roaches and/or any other insects and vermin, the owner shall undertake an expedient means of extermination of such nuisances. Such extermination shall be certified by an approved exterminator. e. All doors and/or lids on appliances, furniture utilized for storage or on heating furnaces shall be locked in order to deny entry to individuals where the potential for physical harm or death may result should said door close and prevent the individual's escape. PM-308.6 Applicability. The standards and requirements of this Article shall apply as long as any dwelling, building and/or commercial structure remains vacant or unoccupied. Upon occupancy, the other appropriate sections of this chapter shall prevail along with other state and local codes and regulations. PM-308.7 Commercial Structures Containing Storefronts Display Windows. As to any commercial structure determined to be vacant as defined herein that contains a storefront, display windows, and/or any area in-tended to exhibit or display merchandise or conduct advertising, the owner of said structure shall place a display or a visual medium which will not by its appearance constitute a blighting factor for adjoining property owners or the public, which is properly maintained. Specifically, the following methods of obstructing windows and/or storefronts are prohibited: placement of newspaper or other types of news print; the painting, soaping or hazing of windows and/or storefronts; the boarding and/or placement of cardboard or other similar material in windows and/or storefronts. This listing is not intended to be exhaustive but rather illustrative as to those types of conditions which are specifically prohibited under this section. PM-308.8 Notice to Abate. Any property owner in violation of any subsection of this Chapter 308 shall first be provided with a Notice to Abate as provided for in The Housing and Property Maintenance Code prior to issuance of a summons for a violation hereunder. PM-308.9 Penalty. Any person, firm, or corporation who shall violate any provisions of this section shall be subject to a fine of five hundred ($500.00) dollars for the first offense and one thousand ($1,000.00) dollars for a second or subsequent offense, or imprisonment for a term not to exceed ninety (90) days, or both, at the discretion of the court. Each day that a violation continues after due notice has been served, in accordance with the terms and provisions hereof, shall be deemed a separate offense. CHAPTER 4 LIGHT, VENTILATION AND OCCUPANCY LIMITATIONS PM-403.4 BASEMENT AND CELLARS: Basement or cellar dwelling units or rooms completely or partially below grade shall not be used for living or sleeping purposes unless: 1. Floors and walls are watertight and so insulated as to prevent entry of moisture. 2. Total window area, total openable are ceiling height in accordance with this code. 3. Required minimum window area of every habitable room is entirely above grade of the ground adjoining such window area. 4. Each basement dwelling unit shall be provided with two (2) means of egress leading directly to the outdoors. P.M. 405.0 OCCUPANCY LIMITATIONS P.M. 405.1a MINIMUM GROSS FLOOR AREA: Every dwelling unit shall contain a minimum gross floor area of not less than one hundred seventy-five (175) square feet for the first occupant, and one hundred twenty-five (125) square feet for each additional occupant. PM-405.3 AREA FOR SLEEPING PURPOSES: Every room occupied for sleeping purposes by one (1) occupant shall contain at least seventy (70) square feet of floor area, and every room occupied for sleeping purposes by more than one (1) person shall contain at least sixty (60) square feet of floor area for each occupant thereof. PM-405.5 MINIMUM OCCUPANCY AREA REQUIREMENTS Minimum Occupancy Area in Square Feet: OCCUPANTS SPACE | 1-2 | 3-5 | 6-10 | 11-15 | 16 or more Living Room | No Requirements | 145 | 175 | 225 | 260 Dining Room | No Requirements | 100 | 120 | 150 | 180 Kitchen | 50 | 70 | 85 | 120 | 145 Bedrooms | MUST COMPLY WITH SECTION PM-405.3 PM-405.8 MINIMUM CEILING HEIGHTS. All habitable spaces shall have a clear ceiling height of seven feet six (7'6") inches. Note: Hallways, corridors, laundry areas, bathrooms, and toilet rooms are not considered habitable space; PM-406 ALTERATIONS. It shall be unlawful to alter, renovate, or add additional dwelling units to any building or structure without first obtaining construction permits and all required approvals. (a) It shall be the responsibility of the owner of the building or structure that has been altered to prove that the use is a legal conforming use. (b) It shall be unlawful to occupy or use the altered building or structure until all applicable construction and other required approvals are received. (c) Any and all alterations, renovations or additions to any building or structure which have been performed without first obtaining construction permits and all required approvals, shall be removed by the owner of the building or structure. CHAPTER 5 PLUMBING FACILITIES AND FIXTURE REQUIREMENTS PM-506.4 WATER HEATING FACILITIES: Water heating facilities shall be properly installed, maintained and capable of providing an adequate amount of water to be drawn at every required sink, lavatory, bathtub, shower and laundry facility at a temperature of not less than one hundred twenty (120°) degrees F nor more than one hundred forty (140°) degrees F. A gas-burning water heater shall not be located in any bathroom, toilet room, bedroom or other occupied room normally kept closed, unless adequate combustion air is provided. An approved combination temperature and pressure relief valve and relief valve discharge pipe shall be properly installed and maintained on water heaters. CHAPTER 6 MECHANICAL AND ELECTRICAL REQUIREMENTS PM-602 HEATING FACILITIES PM-602.2.1 Heat Supply. Where any occupant undertakes by contract, or as a condition of his letting, to supply his own heat through a furnace or boiler which also heats a dwelling unit or rooming unit occupied by other persons, the occupant shall be responsible for supplying heat in accordance with the provisions of subsection. It shall be the responsibility of the owner or operator to maintain heat in every habitable space. Between September 15 through May 31 heat shall be maintained at 68 degrees F. between the hours 6:00 a.m. and 11:00 p.m., and a minimum of 65 degrees F. between the hours of 11:00 p.m. and 6:00 a.m. Any owner or operator who has an express contractual arrangement with an occupant under which the occupant undertakes to supply his own heat through facilities under the occupants exclusive control shall be excepted from the requirement to supply heat. PM-605.2 RECEPTACLES. Every habitable space in a dwelling shall contain at least two (2) separate and remote receptacle outlets. Every laundry area shall contain at least one (1) grounded-type receptacle. Every bathroom shall contain at least one (1) approved receptacle. CHAPTER 7 FIRE SAFETY REQUIREMENTS SMOKE DETECTORS/SMOKE DETECTOR SYSTEMS PM-707.1 Types of Smoke Detectors. Smoke detectors shall be Underwriters Laboratories, Inc. (U.L.), Factory Mutual Research Corporation (F.M.) or other nationally recognized testing laboratory listed ionization or photo-electric type units. a. Single station units shall have the following features: integral alarms capable of emitting a minimum sound intensity of 85 dbA at a ten foot distance, an easily seen and activated manual unit test button or approved alternative and a power source monitor light. All units shall be listed as conforming to latest NFPA No. 72 standards for design and performance. b. All smoke alarms shall comply with the provisions of N.J.A.C. 5:70-4.19(c). PM-707.2 Power Source and Owner Duties. All dwelling unit smoke detectors may be battery-powered single station units and shall be installed in dwelling units provided that the following conditions are met: a. The owner or his representative shall inspect and clean all units and replace batteries in all units annually or as otherwise required in the manufacturer's printed recommendations. b. The owner of a two-family dwelling shall supply each occupant with a copy of the manufacturer's printed instructions for the testing of the installed unit(s). c. In the event the owner of a two-family dwelling who has been notified by an occupant, that such occupant is unable to perform the required monthly testing of detector units in his dwelling or have this performed by a member of his household, the owner shall perform, or cause to be performed, such monthly testing. d. In all common areas, the owner or his representative shall test all smoke detectors and/or detection systems monthly and maintain them as stated in the manufacturer's recommendations. PM-707.3 Required Location of Smoke Detectors in Dwelling Units. Dwelling units in one and two family dwellings shall have smoke detectors installed at locations as follows: a. Each dwelling unit shall have a minimum of one approved single station smoke detector located in close proximity to each sleeping area. Smoke detectors shall be located so that the maximum distance from the detector to any sleeping area exit door shall not exceed ten feet. b. Each level directly connected to a dwelling unit and used by the occupants of that unit shall have a minimum of one approved smoke detector located in the highest ceiling area on that level of the dwelling unit or other approved location, to ensure the earliest detection of fire. PM-707.4 Common Area Smoke Detection Requirements. Common areas in all buildings that do not comply with the minimum fire safety requirements of the current New Jersey Uniform Construction Code shall be required to have an approved system. Alarms shall be located so as to be effectively heard above all other sounds, by all occupants, in every occupied space within the building. a. All corridors up to 30 feet in length which form part of a means of egress shall have a minimum of one approved smoke detector. An additional smoke detector shall be installed for every additional 30 feet or part thereof. Detectors shall be so located as to provide most complete coverage. b. All interior stairways in buildings not enclosed by a minimum one hour fire-rated separation from other common areas and/or dwelling units shall have approved smoke detectors installed at each floor level at either the ceiling of the landing or the high point of the sloped staircase soffit. c. All basements, cellars or attics which lack a minimum one hour fire-rated smooth ceiling surface shall have approved smoke detectors installed at spacings not to exceed 450 square feet of floor space coverage per smoke detector, unless the detector is listed for a greater allowable spacing and approved by the Division of Inspections. d. All basements, cellars or attics which have an existing approved minimum of one hour fire-rated ceiling assembly shall have a minimum of one approved smoke detector per 900 square feet of area, unless the detector is listed for a greater allowable spacing and approved by the Division of Inspections. e. All other use groups within the same fire area shall be considered as common area when not separated by fire assemblies of two (2) hour construction. f. Any mechanical room containing appliances for both dwelling units. PM-707.5 Substitution of Heat Detectors. With the approval of the fire sub-code official, heat detectors may be substituted for smoke detectors in those locations where frequent nuisance alarms would be likely to occur. PM-707.6 All new smoke detector systems shall require permits and inspections as per the State of New Jersey Uniform Construction Code. CHAPTER 8 PM-800.0 DUTIES AND RESPONSIBILITIES OF OCCUPANTS: RESIDENTIAL PM-800.0 OCCUPANCY AND REPORTS WHERE VIOLATIONS EXIST. After notice as required herein occupants shall not occupy or continue to occupy premises which are substandard by reason of failure of the dwelling unit or rooming unit occupied by them or the dwelling or premises to conform to and comply with the requirements of this code. Upon discovery by the occupant of any condition on the premises which constitutes a violation hereof, the occupant shall report the same to the Division of Inspections. PM-800.1 GARBAGE DISPOSAL AND PERSONAL ACCUMULATIONS. Occupants shall place all garbage in the receptacles provided for garbage disposal and shall, where janitor service is not supplied, place for disposal all garbage and other refuse in garbage cans located in the exterior of the premises in an area designated and set forth for this disposal, but such containers may not be stored in the area between dwellings and street side lines or on streets. Where janitorial service for the removal of garbage and other refuse to the exterior of the premises is provided by the owner or operator, then the occupant shall dispose of garbage and other refuse in containers provided therefor by the owner or operator in designated and enclosed areas in the interior of the premises. Garbage and other refuse shall not be thrown out of windows or down dumbwaiters, nor shall garbage and refuse be set out on stairways or fire escapes or in common hallways. All fire escapes, stairways, and common hallways shall be kept free of accumulations of personal belongings. All dumbwaiters shall be operative at all times where in existence and used as a regular part of the garbage disposal system. PM-800.2 INFESTATION ELIMINATION. Every occupant of a single family dwelling shall be responsible for the elimination of infestation in the dwelling on the premises. Every occupant of a dwelling shall be responsible for eliminating all conditions causing infestation which are caused by the occupant, and also those conditions causing infestation which are subject to and under his exclusive control. PM-800.3 PLUMBING MAINTENANCE. Every occupant or operator shall maintain all plumbing fixtures used by him in a clean and sanitary condition and he shall not deposit any material in any fixture or sewer system which would result in stoppage of or damage to the fixtures or sewer system. PM-800.4 WIRING. No extension cords in excess of six feet in length shall be permitted and no ceiling or wall fixture shall be used to supply power to equipment other than that for which they are designed. PM-800.5 NOTICE OF DEFECT TO OWNER. Where the owner or operator would not otherwise know of a defect of any facility, utility, or equipment required to be furnished hereunder and the same is defective or inoperable, each occupant or owner affected thereby shall upon learning of the defect, provide notice to the owner, operator, or other person in charge of the premises. Nothing herein shall be construed to provide a defense to any owner or operator violating this code. PM-801.0 OCCUPANCY. No occupant shall occupy or permit the occupancy of any rooming unit or dwelling unit in violation of the occupancy standards established in subsection 405.5. No occupant shall occupy or continue to occupy a dwelling unit or rooming unit that does not have provision for bathroom facilities. PM-801.1 COOKING. No occupant shall cook in any dwelling unit except where all the required facilities are installed as required under this code. PM-801.2 VIOLATIONS BY MINORS. All adult members of the family shall be responsible and liable for any violation of the stated subsection caused by minors under their care or custody occupying the same dwelling unit if the violations were created or permitted to continue with the knowledge or acquiescence or consent of the adult member. PM-801.3 MISCELLANEOUS PROVISIONS. Owners, occupants and their guests are prohibited from walking standing sitting or lying on the roof or fire escape of any building except in the case of emergency or to effectuate repairs. PM-801.4 OWNERS, OCCUPANTS AND THEIR GUESTS ARE PROHIBITED FROM PLACING RESIDENTIAL FURNITURE ON THE ROOF OR PORCH OF ANY BUILDING. Owner and occupants of the premises are responsible for eliminating and preventing violations of the above provision. PM-801.5 COOKING ON ROOFS. Owners, tenants, occupants and their guests are prohibited from placing or utilizing any cooking devices on the roof of any building.
(Ord. No. O-061803, §§ 1—3, 6-20-18; Ord. No O-081203, § 1, 8-15-12; Ord. No. O-071202, § 1, 7-18-12; Ord. No. O-121103, § 1, 12-21-11; Ord. No. O-010907, §§ 1, 3, 2-4-09; Ord. No. O-120803 § 1, 12-31-08; Ord. O-080507 § 1, 2005; Ord. O-020211 §§ 1—3, 2002; Ord. O-070005 §§ 2—4, 2000; prior code § 14-2)
Ask a question about New Brunswick law
Corpus searches the New Brunswick sections it holds and shows the ones that match, with their citations. Free, no sign-in.