§ 215-11 — Issuance of a certificate of smoke detector and carbon monoxide compliance

Code of the City of Paterson, New Jersey (eCode360 publication current through 2025-12-16) · Paterson City Code § 215-11

Corpus is an independent public-information project, not the official City of Paterson website. Stable reference: corpuslaw.us/code/b192a91b-1b00-40f4-92bb-3486e96dc4b5

§ 215-11: Issuance of a certificate of smoke detector and carbon monoxide compliance.

A. As per the Uniform Fire Code of the State of New Jersey, N.J.A.C. 5:70 et seq., the issuance of a certificate of smoke detector and carbon monoxide compliance, CSDCMC, is required before any one- or two-family dwelling (R-3 or R-4) is sold, leased or otherwise made subject to a change of occupancy. This inspection requirement applies only to one- and two-family dwellings and not to multiple dwellings (R-2) that are inspected by the State Division of Multi-Dwellings. The CSDCMC is valid for a period of six months and is not transferable. B. At least one smoke detector must be present on each level of the home, including the basement and attic. All smoke detectors must be located on the ceiling, no closer than 18 inches from any wall. A smoke detector must be located outside of every bedroom but not more than 10 feet from the bedroom doorway. If the bedrooms are close enough, it is possible that one detector will provide coverage for multiple bedrooms. If in order to comply with the code, a required detector is to be installed in the kitchen, the detector must be a photoelectric-activated detector as opposed to an ionization detector. An acceptable alternative to using the photoelectric detector would be to install a standard ionization-type detector inside that bedroom on the ceiling. C. As per recent code revisions, N.J.A.C. 5:70-4-19(d), carbon monoxide detectors are required to be installed in the immediate vicinity of all sleeping rooms. The carbon monoxide detectors may be installed on the ceiling or a wall; however, the manufacturer's installation instructions must be followed. Carbon monoxide detectors are required to be manufactured, listed and labeled in accordance with UL 2034. Each carbon monoxide detector must be labeled indicating that it meets this requirement. D. All detectors must be installed and operating properly prior to the inspection. The fee for the inspection is as follows: (1) Inspections requested with a lead time of less than four days: $300. (2) Inspections requested with a lead time of four to 10 days: $200. (3) Inspections requested with a lead time of more than 10 days for re-rental: $75. (4) Inspections requested with a lead time of more than 10 days for property sale: $125.

[Added 11-25-2003 by Ord. No. 03-074 ]

Ask a question about Paterson law

Corpus searches the Paterson sections it holds and shows the ones that match, with their citations. Free, no sign-in.