§ 219-17 — Specific standards for flood hazard reduction
Code of the City of Paterson, New Jersey (eCode360 publication current through 2025-12-16) · Paterson City Code § 219-17
Corpus is an independent public-information project, not the official City of Paterson website. Stable reference: corpuslaw.us/code/6f62a336-d21c-4dcb-85fb-187b40f64830
§ 219-17: Specific standards for flood hazard reduction.
In all areas of special flood hazards where base flood elevation data have been provided as set forth in § 219-7, Basis for establishing areas of special flood hazard, or in § 219-14B, Use of other base flood data, the following standards are required: A. Residential construction. New construction and substantial improvement of any residential structure located in an A, AE, AO or AH zone shall have the lowest floor, including basement together with the attendant utilities (including all electrical, heating, ventilating, air-conditioning and other service equipment) and sanitary facilities, elevated at or above the more restrictive of the following: (1) For A or AE zones: (a) Base flood elevation (published FIS/FIRM) plus one foot; (b) The best available flood hazard data elevation plus one foot; (c) As required by ASCE/SEI 24-14, Table 2-1; or (d) As required by N.J.A.C. 7:13-3. (2) For AO or AH zones on the municipality's FIRM, to elevate above the depth number specified in feet plus one foot, above the highest adjacent grade (at least three feet if no depth number is specified), and require adequate drainage paths around structures on slopes to guide floodwaters around and away from proposed structures. (3) Record the method and elevation used above and the best available flood hazard design data elevation, date and revision in the local development permit. B. Nonresidential construction. In an area of special flood hazard, all new construction and substantial improvement of any commercial, industrial or other nonresidential structure located in an A, AE, AO or AH zone shall have the lowest floor, including basement together with the attendant utilities and sanitary facilities as well as all electrical, heating, ventilating, air-conditioning and other service equipment: Either: (1) Elevated at or above the more restrictive of the following: (a) For A or AE zones: [1] Base flood elevation (published FIS/FIRM) plus one foot; [2] The best available flood hazard data elevation plus one foot; [3] As required by ASCE/SEI 24-14, Table 2-1; or [4] As required by N.J.A.C. 7:13-3; (b) For AO or AH zones on the municipality's FIRM to elevate above the depth number specified in feet plus one foot, above the highest adjacent grade (at least three feet if no depth number is specified), and require adequate drainage paths around structures on slopes to guide floodwaters around and away from proposed structures; (c) Record the method and elevation used above and the best available flood hazard design data elevation, date and revision in the local development permit. or: (2) Be floodproofed so that below the more restrictive of the following: (a) For A or AE zones: [1] Base flood elevation (published FIS/FIRM) plus one foot; [2] The best available flood hazard data elevation plus one foot; [3] As required by ASCE/SEI 24-14, Table 6-1; or [4] As required by N.J.A.C. 7:13-3; [5] AO or AH zone elevation based upon the highest adjacent grade, plus the depth number specified in feet, plus one foot (at least three feet if no depth number is specified) and require adequate drainage paths around structures on slopes to guide floodwaters around and away from proposed structures; (b) The structure is watertight with walls substantially impermeable to the passage of water; (c) Have structural components capable of resisting hydrostatic and hydrodynamic loads and effects of buoyancy; (d) Be certified by a registered professional engineer or architect that the design and methods of construction are in accordance with accepted standards of practice for meeting the applicable provisions of this subsection. Such certification shall be provided to the official as set forth in § 219-14C(2); and (e) Record the method and elevation used above and the best available flood hazard design data elevation, date and revision in the local development permit. C. Manufactured homes. (1) Manufactured homes shall be anchored in accordance with § 219-16A(2). (2) All manufactured homes to be placed or substantially improved within an area of special flood hazard shall: (a) Be consistent with the need to minimize flood damage; (b) Be constructed to minimize flood damage; (c) Have adequate drainage provided to reduce exposure to flood damage; (d) Be elevated on a permanent foundation such that the top of the lowest floor is at or above the more restrictive of the following: [1] Base flood elevation (published FIS/FIRM) plus one foot; [2] The best available flood hazard data elevation plus one foot; [3] As required by ASCE/SEI 24-14, Table 2-1; or [4] As required by N.J.A.C 7:13-3; [5] AO or AH zone elevation based upon the highest adjacent grade, plus the depth number specified in feet, plus one foot (at least three feet if no depth number is specified) and require adequate drainage paths around structures on slopes to guide floodwaters around and away from proposed structures; (e) Record the method and elevation used above and the best available flood hazard design data elevation, date and revision in the local development permit. (3) All recreational vehicles located within an area of special flood hazard shall either: (a) Be on site for fewer than 180 consecutive days; (b) Be fully licensed and ready for highway use; or (c) Meet the requirements of § 219-12 and § 219-12C.
[Amended 3-10-2020 by Ord. No. 20-014 ]
Ask a question about Paterson law
Corpus searches the Paterson sections it holds and shows the ones that match, with their citations. Free, no sign-in.
