§ 275-9 — Minimum standards for light, ventilation and heating

Code of the City of Paterson, New Jersey (eCode360 publication current through 2025-12-16) · Paterson City Code § 275-9

Corpus is an independent public-information project, not the official City of Paterson website. Stable reference: corpuslaw.us/code/a14570f1-c685-4f7c-a752-a5747885d321

§ 275-9: Minimum standards for light, ventilation and heating.

No person shall occupy as owner-occupant or let to another for occupancy any dwelling or dwelling unit, for the purpose of living therein, which does not comply with the following requirements: A. Every habitable room shall have at least one (1) window or skylight facing directly to the outdoors. The minimum total window area, measured between stops, for every habitable room shall be ten percent (10%) of the floor area of such room. Whenever walls or other portions of structures face a window of any such room and such light-obstruction structures are located less than three (3) feet from the window and extend to a level above that of the ceiling of the room, such a window shall not be deemed to face directly to the outdoors and shall not be included as contributing to the required minimum total window area. Whenever the only window in a room is a skylight-type window in the top of such room, the total window area of such skylight shall equal at least fifteen percent (15%) of such room. B. Every habitable room shall have at least one (1) window or skylight which can easily be opened or such other device as will adequately ventilate the room. The total of openable window area in every habitable room shall be equal to at least forty-five percent (45%) of the minimum window area size or minimum skylight-type window size, as required in Subsection A of this section, except where there is supplied some other device affording adequate ventilation and approved by the Health Officer. C. Every bathroom and water closet compartment shall comply with the light and ventilation requirements for habitable rooms contained in Subsections A and B of this section, except that no window or skylight shall be required in adequately ventilated bathrooms and water closet compartments equipped with a ventilation system which is kept in continuous operation and approved by the Health Officer. D. Every dwelling shall be supplied with electric service which shall be installed and maintained in accordance with the requirements of the construction code enforcing agency of the city. E. Every dwelling shall have heating facilities which are properly installed, are maintained in safe and good working condition and are capable of safely and adequately heating all habitable rooms, bathrooms and water closet compartments in every dwelling unit located therein to a temperature as required by Chapter 267, Heating, Article I, Responsibility To Provide Minimum Temperature.[1] F. Every public hall and stairway in every multiple dwelling containing three (3) or more dwelling units shall be adequately lighted at all times. Every public hall and stairway in structures devoted solely to dwelling occupancy and containing not more than two (2) dwelling units may be supplied with conveniently located light switches, controlling an adequate lighting system which may be turned on when needed, instead of full-time lighting. G. Every basement or cellar window used or intended to be used for ventilation and every other opening to a basement which might provide an entry for rodents shall be supplied with a screen or such other device as will effectively prevent their entrance.

Ask a question about Paterson law

Corpus searches the Paterson sections it holds and shows the ones that match, with their citations. Free, no sign-in.