§ 438-7 — Construction and equipment requirements; location restriction; fencing; water supply
Code of the City of Paterson, New Jersey (eCode360 publication current through 2025-12-16) · Paterson City Code § 438-7
Corpus is an independent public-information project, not the official City of Paterson website. Stable reference: corpuslaw.us/code/d166d22a-de55-4fdd-8a77-2889c4824624
§ 438-7: Construction and equipment requirements; location restriction; fencing; water supply.
A. No provision of this chapter shall mitigate any provision of the Building Code that is applicable to swimming pools. B. The construction of any swimming pool (portable or permanent) shall follow the design and safety precautions of good building practice. All pools shall be designed and constructed so as to facilitate emptying and cleaning and shall be maintained and operated in such manner as to be clean and sanitary at all times. C. All permanent swimming pools shall be so constructed, developed, installed and maintained as to provide necessary equipment for chlorination and other disinfection and filtration. The filtration system shall have sufficient capacity to complete the recirculation of pool water in 18 hours or less. D. Swimming pools will not be located over or within 20 feet horizontally from any septic disposal field or within 10 feet horizontally of a septic tank or distribution box. No property will be subdivided if the result will be that a swimming pool will be separated in ownership from an adjoining residence. E. All private swimming pools now existing or hereafter constructed, installed, established or maintained shall be enclosed with a substantial barrier and gate that complies with the minimum requirements listed below: (1) The top of the barrier shall be at least 72 inches above grade measured on the side of the barrier that faces away from the swimming pool. The maximum vertical clearance between grade and the bottom of the barrier shall be two inches, measured on the side of the barrier that faces away from the swimming pool. The maximum vertical clearance at the bottom of the barrier may be increased to four inches when grade is a solid surface, such as a concrete deck, or when the barrier is mounted on top of the aboveground pool structure. When barriers have horizontal members spaced less than 54 inches apart, the horizontal members shall be placed on the pool side of the barrier. Any decorative design work on the side away from the swimming pool, such as protrusions, indentations or cutouts, which render the barrier easily climbable, is prohibited. (2) Openings in the barrier shall not allow passage of a sphere of 1 3/4 inches in diameter. (3) When vertical spacing between such openings is 54 inches or more, the opening size may be increased such that the passage of a sphere four inches in diameter is not allowed. (4) For fencing composed of vertical and horizontal members, the spacing between vertical members may be increased up to four inches when the distance between the tops of horizontal members is 54 inches or more. (5) Chain link fences used as the barrier shall not be less than 11 gauge. (6) Access gates shall comply with the requirements of Subsection E(3) through (5). Pedestrian access gates shall be self-closing and have a self-latching device. Where the release mechanism of the self-latching device is located less than 54 inches from the bottom of the gate, the release mechanism shall be located on the pool side of the barrier at least three inches below the top of the gate, and the gate and barrier shall have no opening greater than 1/2 inch within 18 inches of the release mechanism. Pedestrian gates shall swing away from the pool. Any gates other than pedestrian access gates shall be equipped with lockable hardware or padlocks and shall remain locked at all times when not in use. (7) Where a wall of a dwelling unit serves as part of the barrier and contains door openings between the dwelling unit and the outdoor swimming pool that provide direct access to the pool, a separation fence meeting the requirements of Subsection E(3), (4), (5) and (6) of § 438-7 shall be provided. (8) When approved by the Building Official, one of the following may be used: (a) Self-closing and self-latching devices installed on all doors with direct access to the pool with the release mechanism located a minimum of 54 inches above the floor. (b) An alarm installed on all doors with direct access to the pool. The alarm shall sound continuously for a minimum of 30 seconds within seven seconds after the door and its screen, if present, are opened, and shall be capable of providing a sound pressure level of not less than 85 dBA when measured indoors at 10 feet. The alarm shall automatically reset under all conditions. The alarm system shall be equipped with a manual means, such a touchpad or switch, to temporarily deactivate the alarm for a single opening. Such deactivation shall last no longer than 15 seconds. The deactivation switch shall be located at least 54 inches above the threshold of the door. (c) Other means of protection may be acceptable so long as the degree of protection afforded is not less than that afforded by any of the devices described above. (d) Where an aboveground pool structure is used as a barrier or where the barrier is mounted on top of the pool structure, and the means of access is a ladder or steps, then the ladder or steps shall be capable of being secured, locked or removed to prevent access or the ladder or steps shall be surrounded by a barrier that meets the requirements of Subsection E(2) through (7). When the ladder or steps are secured, locked or removed, any opening created shall be protected by a barrier complying with Subsection E(3) through (7). (9) Where a window faces a swimming pool enclosure, said window shall be equipped with a screwed-in-place wire mesh screen, a keyed lock that prevents opening the window more than four inches or a latching device located not less that 54 inches above the floor. Emergency escape or rescue windows in bedrooms which face swimming pool enclosures shall be equipped with a latching device located no less that 54 inches above the floor. (10) An above-the-ground pool having a sidewall height of at least four feet above finished ground level is exempt from the above fencing requirement, provided that access to the pool is by means of a removable or retractable ladder. A retractable ladder shall be equipped with a key-operated locking device which will secure the ladder in the retractable position when not in use. (11) An above-the-ground pool of sidewall height less than four feet above finished ground level may be exempt from the above fencing requirements, provided that a suitable strong protective covering is placed over the pool and adequately secured whenever the pool is unattended or not in use; and provided, further, that the above provisions with regard to ladders are also adhered to where applicable. F. No electrical switches, outlets or appliances and no electrical wiring not in well-grounded shielding conduit shall be within a three-foot radius of any point of the pool's edge or surface as measured in any direction. No electrical installation shall be so constructed or located that in the event that it should collapse or fall, it would fall into the pool. The circulating pumps, motors, lights, filtration equipment and all other electrical equipment used in conjunction with a swimming pool shall be electrically supplied through an underwriter's approved ground fault circuit breaker. Such breaker will be mounted within the main service panel within the building on which public service has mounted its meter. Ground fault breakers designed to plug into existing wall receptacles will not be approved for pool use. All electrical equipment will be installed as to comply with the National Electrical Code, 2002, and as thereafter adopted by the State of New Jersey. G. There shall be no physical connection between a potable water system and a pool. The water supply system for a pool shall be in compliance with the National Standard Plumbing Code, 2004, and as thereafter adopted annually by the State of New Jersey. H. Preferably, the discharge should empty into a storm sewer, stream or dry well of adequate capacity. In no case shall the pool water be discharged within 50 feet of a well or within 25 feet of an adjacent property, pool or residence.
Ask a question about Paterson law
Corpus searches the Paterson sections it holds and shows the ones that match, with their citations. Free, no sign-in.