A505-22 — Prohibited industrial wastes
Code of the City of Paterson, New Jersey (eCode360 publication current through 2025-12-16) · Paterson City Code § A505-22
Corpus is an independent public-information project, not the official City of Paterson website. Stable reference: corpuslaw.us/code/2d1ab3b2-283e-46e9-8d66-79f54de1b6c3
§ A505-22: Prohibited industrial wastes.
No person shall discharge or deposit or cause or allow to be discharged or deposited into the treatment works or public sewer any waste which causes or contains the following: A. Explosive wastes. Wastes in such quantity which may create a fire or explosion hazard to the treatment works, collection system or to the operation of the system, including but not limited to wastewater with a closed cup flash point of less than one hundred forty degrees Fahrenheit (140° F.) or sixty degrees Centigrade (60° C.) using the test methods specified in 40 CFR 261.21. Additional quantitative limitations on explosive wastes are specified in Appendix B.[1] B. Corrosive wastes. Wastes in such quantity which will cause corrosion or deterioration of the treatment works. Unless a higher limit is otherwise stated in the sewer connection permit issued to a user, all wastes shall have a pH not less than five (5). Unless otherwise stated in the sewer connection permit, all wastes shall have a pH not more than ten point five (10.5). Prohibited materials include but are not limited to acids, sulfides, concentrated chloride or fluoride compounds, etc. C. Solids or viscous wastes. Solids or viscous wastes in amounts which would cause obstruction to the flow in a sewer or otherwise interfere with the proper operation of the treatment works. Prohibited materials include but are not limited to uncomminuted garbage, bones, hides or fleshings, cinders, sand, stone or marble dust, glass, etc. D. Oils and grease. (1) Petroleum oil, nonbiodegradable cutting oil or products of mineral oil origin in amounts that will cause interference or pass-through. (2) Any industrial wastes containing floatable fats, wax, grease or oils. (3) Any industrial wastes containing more than one hundred (100) milligrams per liter of petroleum-based oil or grease. E. Noxious materials. (1) Pollutants which result in the presence of toxic gases, vapors or fumes within the POTW in a quantity that may cause acute worker health and safety problems. (2) Noxious liquids or gases which, in sufficient quantity, either singly or by interaction with other wastes, are capable of creating a public nuisance or hazard to life or are or may be sufficient to prevent entry into a sewer for its maintenance and repair. F. Radioactive wastes. Radioactive wastes or isotopes of such half-life or concentration that they do not comply with regulations or orders issued by the appropriate authority having control over their use and which will or may cause damage or hazards to the treatment works or personnel operating the system. G. Interference. Any waste, including oxygen demanding wastes (BOD, etc.), released in a discharge at a flow rate and/or pollutant concentration which an industrial user knows or has reason to know will interfere with the PVSC treatment works. H. Excessive discharge rate. Industrial wastes discharged in a slug or such volume or strength so as to cause a treatment process upset and subsequent loss of treatment efficiency. I. Heat. (1) Any discharge in excess of one hundred fifty degrees Fahrenheit (150° F.) [sixty-five degrees Centigrade (65° C.)]. (2) Heat in amounts which would inhibit biological activity in the PVSC treatment works resulting in a treatment process upset and subsequent loss of treatment efficiency. J. Unpolluted waters. Any unpolluted water, including but not limited to cooling water and uncontaminated stormwater, which will increase the hydraulic load on the treatment system, except as approved by the PVSC. K. Dilution water. Any water added for the purpose of diluting wastes which would otherwise exceed applicable maximum concentration limits. L. Violations. Wastes which cause the PVSC treatment plant to violate its NJPDES permit, applicable receiving water standards, permit regulating sludge which is produced during treatment or any other permit issued to the PVSC. M. Ultrahazardous toxics. Those wastes designated by the EPA as sufficiently toxic that they shall not be discharged to the sanitary sewer in any concentrations. N. Trucked pollutants. Any trucked or hauled pollutants, except at discharge points designated by the Chief Executive Officer, and only after approval is issued by the PVSC. O. Groundwater. Any groundwater, whether contaminated or uncontaminated, unless specifically authorized by the PVSC. P. Stormwater. Any stormwater, whether contaminated or uncontaminated, unless specifically authorized by the PVSC. Editor's Note: Appendix B, Pretreatment Limitations, is included at the end of this chapter .
Ask a question about Paterson law
Corpus searches the Paterson sections it holds and shows the ones that match, with their citations. Free, no sign-in.
