§ 14-16-5-1(D) — MIXED-USE ZONE DISTRICTS
Albuquerque, New Mexico Code of Ordinances (2026 S-96: current through Ordinance 2026-033, passed 8-17-2026) · Albuquerque Integrated Development Ordinance § 14-16-5-1(D)
Corpus is an independent public-information project, not the official City of Albuquerque website. Stable reference: corpuslaw.us/code/42b89a0d-9fc5-4d9d-bcbc-748223117884
5-1(D) MIXED-USE ZONE DISTRICTS
5-1(D)(1) Mixed-use Zone District Table All development in any Mixed-use zone district shall comply with the dimensional standards in Table 5-1-2, unless an exception or a different standard is stated in another section of this IDO. § 14-16-2-4(E) [Mixed-use – Form-based Zone District (MX-FB)] includes dimensional standards for MX-FB sub-zones. Table 5-1-2: Mixed-use Zone District Dimensional Standards AC = Activity Center; MS = Main Street area; MT = Major Transit area; PT = Premium Transit area; UC = Urban Center BR = bedroom DU = dwelling units Note: Any different dimensional standards in Part 14-16-3 (Overlay Zones) and § 14-16-5-9 (Neighborhood Edges) applicable to the property shall supersede the standards in this table. Zone District | MX-T[1] | MX-L | MX-M | MX-H Site Standards Usable open space, minimum[2] | Efficiency or 1 BR: 225 sq. ft./unit 2 BR: 285 sq. ft./unit ≥3 BR: 350 sq. ft./unit UC-MS-PT: 50% reduction Setbacks[3][4][5][6] Front, minimum | 5 ft. UC-MS-PT: 0 ft. [7] Front, maximum | N/A UC-MS-PT: 15 ft. Side, minimum | Interior: 0 ft.; Street side of corner lots: 5 ft. UC-MS-PT: 0 ft. Side, maximum | N/A UC-MS-PT: Interior: N/A; Street side of corner lots: 15 ft.[7] Rear, minimum | 15 ft. UC-MS-PT: 0 ft. where rear lot line abuts a street or alley Rear, maximum | N/A Building Height[6] Maximum Citywide | 30 ft. | 38 ft. | 48 ft. | 68 ft. AC-MT | 42 ft. | 50 ft. | 60 ft. | 80 ft. UC-MS-PT | 54 ft. | 62 ft. | 72 ft. | 92 ft. No maximum | For multi-family residential dwellings in or within ¼ mile (1,320 ft. of MS-PT) N/A | For portions of building >100 ft. from all lot lines Bonuses Workforce Housing | AC-MT: 12 ft. UC-MS-PT: 24 ft. Structured Parking | UC-AC-MS-PT-MT: 12 ft. | UC-AC-MS-PT-MT: 24 ft. [1] Residential development that qualifies for funding through Article 14-17 of ROA 1994 (Family Housing Developments) may be eligible for development incentives specified in that Article. [2] Usable open space requirements specified in this table are for multi-family residential development only. Additional usable open space requirements in § 14-16-4-3(B)(3)(i) (Dwelling, Cottage Development) and § 14-16-4-3(B)(5)(a) (Dwelling, Townhouse) may apply to low- density residential development in any Mixed-use zone district. [3] At corners and junctions with driveways, drive aisles, or alleys, additional clear sight triangle requirements in the DPM may apply. Table 5-1-2: Mixed-use Zone District Dimensional Standards AC = Activity Center; MS = Main Street area; MT = Major Transit area; PT = Premium Transit area; UC = Urban Center BR = bedroom DU = dwelling units Note: Any different dimensional standards in Part 14-16-3 (Overlay Zones) and § 14-16-5-9 (Neighborhood Edges) applicable to the property shall supersede the standards in this table. Zone District | MX-T[1] | MX-L | MX-M | MX-H [4] For all low-density residential development, any driveway on a front or street side lot line must meet the standards in § 14-16-5-3(C)(3)(b) (Driveways, Drive Aisles, and Access). [5] For buildings constructed on a lot line abutting a privately owned lot that is not under the same ownership as the subject property, § 14- 16-5-1(F) (Buildings Constructed on a Lot Line) applies. [6] Greater setbacks and/or reduced heights may be required for compliance with the National Electrical Safety Code (NESC) along lot lines that abut, are adjacent to, or within properties that contain overhead power lines and/or electric utility easements. Electric service provision from the Public Service Company of New Mexico (PNM) will also depend on adequate structure clearance requirements as outlined in the PNM Electric Service Guide. [7] In UC-MS-PT areas, all development must meet the standards in § 14-16-5-1(D)(2). 5-1(D)(2) UC-MS-PT Areas 5-1(D)(2)(a) Where sidewalks are less than 10 feet wide, the minimum front setback shall be 10 feet. 5-1(D)(2)(b) A minimum of 50 percent of front property line width must be occupied by the primary building, outdoor seating and gathering area, or outdoor dining area constructed within 15 ft. of the property line. 1. On a corner lot, the required minimum of 50 percent must begin at the corner. 2. A 3-foot wall and trees spaced 20 feet on center shall be required between any outdoor seating and gathering area or outdoor dining area and a parking or loading area. 5-1(D)(2)(c) For lots where there are 2 or more street side lot lines, the maximum side setback applies only to one side.
Ask a question about Albuquerque law
Corpus searches the Albuquerque sections it holds and shows the ones that match, with their citations. Free, no sign-in.
