§ 14-16-5-7(F) — RETAINING WALL STANDARDS
Albuquerque, New Mexico Code of Ordinances (2026 S-96: current through Ordinance 2026-033, passed 8-17-2026) · Albuquerque Integrated Development Ordinance § 14-16-5-7(F)
Corpus is an independent public-information project, not the official City of Albuquerque website. Stable reference: corpuslaw.us/code/39b723f3-66a4-4cb0-812d-85a2b7ef031b
5-7(F) RETAINING WALL STANDARDS
5-7(F)(1) Maximum Height 5-7(F)(1)(a) Retaining walls shall have a maximum height as specified in § 14-16-5-7(D) (Maximum Wall Height) unless a higher wall is approved by the City Engineer as necessary on a particular lot. 5-7(F)(1)(b) Retaining walls higher than 6 feet tall shall be terraced to minimize visual impacts on residents, neighboring properties, and the public realm. Terracing shall be limited to 3 tiers. 5-7(F)(2) Terracing 5-7(F)(2)(a) A terrace at least 4 feet wide, with a maximum slope of 1:3 (rise:run), shall be provided between each tier to create pockets for landscaping. Reduced terrace depths may be administratively approved by the City Engineer where site constraints limit the amount of space available to accommodate the minimum required width. 5-7(F)(2)(b) Terraces between retaining wall tiers shall be vegetated with permanent landscaping to screen retaining walls and provide visual interest unless soil conditions are determined by a licensed engineer to be unsuitable due to geologic hazards. 5-7(F)(3) Setback Retaining walls must be set back so that the underground footing does not encroach on any abutting public right-of-way.
Ask a question about Albuquerque law
Corpus searches the Albuquerque sections it holds and shows the ones that match, with their citations. Free, no sign-in.