Sec. 11-33. - Amendments.
The fire code adopted in section 11-26 is amended as set forth in this section. When an existing section number of the fire code is referred to in this section, the text in this section shall control. When a new section or subsection is referred to in this section it shall be added to the fire code as adopted. The fire code is amended and changed as follows: Chapter 1 Scope and Administration. Section 101.1 Title shall be amended to read as follows: These regulations shall be known as the Fire Code of the City of Las Cruces, hereinafter referred to as "this code". Section 104.6 Official records shall be amended to read as follows: The fire code official shall keep official records as required by Sections 104.6.1 through 104.6.4. Such records shall be retained in accordance with the record retention requirements established by the City of Las Cruces and State of New Mexico. Section 104.11.2 Fire prevention personnel and police authority is added to read as follows: A. Members of the fire prevention services shall have the powers of a police officer in performing their duties under this code when: 1. Such members of the fire prevention services have been certified by a law enforcement academy authorized by the State of New Mexico; and 2. Such members have been commissioned as police officers by the City of Las Cruces. B. Members of the fire prevention services who meet the requirement stated in paragraphs (1) and (2) of subpart A of this section shall have the following powers: 1. Powers of arrest for criminal matters; 2. Authority to carry such weapons and utilize such equipment necessary in the discharge of their duties pursuant to this code; 3. Authority to investigate arson and related crimes if so appointed and authorized by the Las Cruces Police Chief. C. All other members of the fire department who do not meet the requirements of subpart A of this section shall have the power to issue citations only for violations of this code and chapter 11 of the Las Cruces Municipal Code. Section 104.12.2 Obstructing operations shall be amended to read as follows: No person shall obstruct the operations of the fire department in connection with extinguishment or control of any fire, or actions relative to other emergencies, nonemergency incidents or training, or disobey any lawful command of the fire chief or member of the fire department or any lawful order of a police officer assisting the fire department. Section 105 Required construction permits shall be amended to read as follows: The fire code official is authorized to issue construction permits for work as set forth in Sections 105.1.1 through 105.6.2. Such permits shall be processed through the City of Las Cruces Community Development Department and shall be in conformance with the requirements established by this code and the Community Development Department. Section 105.1 General shall be amended to read as follows: Permits required by the fire code official shall be in accordance with section 105. Exception: Permits issued by the City of Las Cruces Community Development Department. Section 105.6.1.1 Design Safety Margin shall be added to read as follows: Unless otherwise approved by the Fire Code Official all automatic sprinkler systems shall be designed with a minimum ten psi safety margin. Section 105.6.1.2 Hydraulic calculations required shall be added to read as follows: When required by the Fire Code Official, hydraulic calculations shall be provided for modification to an existing automatic fire-extinguishing system requiring the installation of additional heads when either of the following occur: 1. Number of heads being added exceeds ten. 2. Number of heads being added is greater than ten percent of total heads for the system. The fire code official may require hydraulic calculations be submitted for any modification to an existing system when deemed necessary to adequately evaluate the impact on the system. Section 106 Construction documents shall be amended to read as follows: Construction documents shall be in accordance with this section and requirements established by the City of Las Cruces Community Development Department. Section 111.1 Board of appeals established shall be amended to read as follows: Whenever the Fire Chief disapproves an application or refuses to grant a permit applied for, or when it is claimed that the provisions of the code do not apply or that the true intent and meaning of the code have been misconstrued or wrongly interpreted, applicant may appeal from the decision to city council by writing to the fire chief requesting an appeal within 30 days of the aggrieved action. Section 111.2 Limitations on authority shall be deleted in its entirety. Section 111.3 Qualifications shall be deleted in its entirety. Section 112.4 Violation penalties shall be amended to read as follows: Persons who shall violate a provision of this code or shall fail to comply with any of the requirements thereof or who shall erect, install, alter, repair or do work in violation for the approved construction documents or directive of the fire code official, or of a permit or certificate used under provisions of this code, shall be guilty of a petty misdemeanor, punishable by a fine of not more than $500.00 or by imprisonment not exceeding 90 days, or both such fine and imprisonment. Each day that a violation continues after due notice has been served shall be deemed a separate offense. Section 113.4 Failure to comply shall be amended to read as follows: Any person who shall continue any work after having been served with a stop work order, except such work as that person is directed to perform to remove a violation or unsafe condition, shall be considered to be in violation of this code and shall be subject to the penalties as set forth in Section 112.4. Chapter 3 General Requirements Section 315.1 is added to read as follows: Electric Vehicles & Personal mobility devices. Electrically powered vehicles and personal mobility devices shall not be displayed, stored, or serviced indoors unless specifically authorized by the Fire Code Official or in conformance with the provisions of Appendix N. Chapter 4 Emergency Planning and Preparedness Table 405.3 Fire and evacuation drill frequency and participation shall be amended as follows: Group H occupancies shall be included with Group A occupancies in the table. Chapter 5 Fire Service Features Section 505.1 Address numbers shall be amended to read as follows: New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. Numbers shall be not less than two inches in width and three inches in height. Address identification shall also conform to section 30-1 of the Las Cruces Municipal Code. Section 507.5.1.2 Fire protection in recreational vehicle, mobile home and manufactured housing parks, sales lots and storage lots is added to read as follows: Fire protection in recreational vehicle, mobile home and manufactured housing parks, sales lots and storage lots shall provide and maintain fire hydrants and access roads in accordance with sections 503 and 507. Chapter 9 Fire Protection and Life Safety Features Section 901.4.7 Pump and Riser room size shall be amended to read as follows: Where provided, fire pump rooms and automatic sprinkler system riser rooms shall be designated with adequate space for all equipment necessary for the installation, as defined by the manufacturer, with sufficient working space around the stationary equipment. Clearances around equipment to the elements of permanent construction, including other installed equipment and appliances, shall be sufficient to allow inspection, service, repair, or replacement without removing such elements of permanent construction or disabling the function of a required fire-resistance rated assembly. Fire pump and automatic sprinkler system riser rooms shall be provided with a door(s) to the exterior and an unobstructed passageway large enough to allow removal of the largest piece of equipment. Section 902.1 Definitions shall have the definition of Standpipe System, Classes of, amended to read as follows: Standpipe classes are as follows: Class I system. A system providing 2.5-inch (64 mm) hose connections to supply water for use by fire departments and those trained in handling heavy fire streams. Class II system. A system providing 1.5-inch (38 mm) hose stations to supply water for use primarily by the building occupants or by the fire department during initial response. 1.5-inch hoses and hose cabinets shall not be provided, unless required by the Fire Code Official. Class III system. A system providing 1.5-inch (38 mm) hose stations to supply water for use by building occupants and 2.5-inch (64 mm) hose connections to supply a larger volume of water for use by fire departments and those trained in handling heavy fire streams. 1.5-inch hoses and hose cabinets shall not be provided, unless required by the Fire Code Official. Section 903.2 Exception shall be deleted in its entirety. Section 903.4 Exceptions shall be amended to read as follows: 2. Limited area systems serving fewer than 20 sprinklers in other than Group H and Group I occupancies. Section 903.4.4 Multi Story Buildings shall be added to read as follows: When required by the Fire Code Official, approved supervised indicating control valves shall be provided in multi-story buildings and attached tenant spaces. For the purpose of this section a basement shall be considered a story. Section 913.4 Valve supervision shall be amended to read as follows: Where provided, the fire pump suction, discharge and bypass valves, and the isolation valves on the backflow prevention device or assembly shall be supervised open by one of the following methods: 1. Central-station, proprietary, or remote-station signaling service. 2. Local signaling service that will cause the sounding of an audible signal at a constantly attended location when approved by the fire code official. Numbers 3. and 4. shall be deleted in their entirety. Chapter 23 Motor Fuel-Dispensing Facilities and Repair Garages Section 2306.2.3.1 Existing above-ground tanks used for dispensing into motor vehicles is added to read as follows: Existing above-ground tanks shall comply with Section 2306.2.3 Chapter 24 Flammable Finishes Section 2404.9.2 Frequency shall be amended to read as follows: Spraying operations shall not be of a continuous nature and shall not exceed 9 square feet per day. Chapter 56 Explosives and Fireworks Section 5601.1.3 Exceptions shall be amended as follows: Exception 2 shall be deleted in its entirety. Chapter 61 Liquefied Petroleum Gases Section 6108.1 General shall be amended to read as follows: Fire protection shall be provided for installations having storage containers with a water capacity of more than 4,000 (15,140 L) gallons as required by Section 6.25 of NFPA 58.
(Ord. No. 2668, § II(Exh. A), 10-1-12; Ord. No. 2802, § I(Exh. A), 1-17-17; Ord. No. 3052, § I(Exh. A), 12-4-23)
Ask a question about Las Cruces law
Corpus searches the Las Cruces sections it holds and shows the ones that match, with their citations. Free, no sign-in.