Sec. 30-722. - Amendments.

(A) 2021 International Building Code. The Building Code adopted by reference in subsection 30-721(A)(1) is amended, altered and changed as follows: (1) Section 101 "General" exclude in its entirety and see Chapter 30, LCMC 1997, as amended. (2) Section 103 "Code Compliance Agency" exclude in its entirety. (3) Section 104 "Duties and Powers of the Building Official." See this Section of the IBC and Chapter 30, LCMC 1997, as amended. (4) Section 105 "Permits" exclude in its entirety except for 105.2.1 through 105.2.3 and see Chapter 30, LCMC 1997, as amended. (5) Section 107 "Construction Documents" exclude in its entirety and see Chapter 30, LCMC 1997, as amended. (6) Section 110 "Inspections" exclude in its entirety and see Chapter 30, LCMC 1997, as amended. (7) Section 111 "Certificate of Occupancy" exclude in its entirety and see Chapter 30, LCMC 1997, as amended. (8) Section 112.3 "Authority to disconnect service utilities" is amended to read as follows: The building official shall have the authority to authorize disconnection of utility of service to the building, structure or system regulated by this code and the referenced codes and standards set forth in Section 30-721, LCMC 1997, as amended, in case of emergency where necessary to eliminate an immediate hazard to life or property or when such utility connection has been made without the approval required by Section 112.1 or 112.2. The building official shall notify the service utility, and wherever possible the owner and occupant of the building, structure, or service system of the decision to disconnect prior to taking such action. If not notified prior to disconnecting, the owner or occupant of the building, structure, or system shall be notified in writing, as soon as practical thereafter. (9) Section 113 "Means of Appeals" is excluded in its entirety and see Chapter 30, LCMC 1997, as amended. (10) Section 3305 "Sanitary" is amended to read as follows: New construction and additions/alterations shall have on-site portable bathroom facilities for each project. If owners and/or contractors wish to share facilities, a request in writing, submitted for approval by the Building Official, is required. Exception: Whenever arrangements have been made with the property owner, persons working on additions/alterations may use existing on-site facilities. (B) 2021 International Residential Code. The Residential Code adopted by reference in subsection 30-721(A),(2) is amended, altered and changed as follows: (1) Section R101 "General" exclude in its entirety and see Chapter 30, LCMC 1997, as amended. (2) Section R103 "Department of Building Safety" exclude in entirety and see Chapter 30, LCMC 1997, as amended. (3) Section R104 "Duties and Powers of the Building Official" See this Section of the IBC and Chapter 30, LCMC 1997, as amended. (4) Section R105 "Permits" exclude in its entirety and see Chapter 30, LCMC 1997, as amended. (5) Section R106 "Construction Documents" exclude in its entirety and see Chapter 30, LCMC 1997, as amended. (6) Section R109 "Inspections" exclude in its entirety and see Chapter 30, LCMC 1997, as amended. (7) Section R110 "Certificate of Occupancy" exclude in its entirety and see Chapter 30, LCMC 1997, as amended. (8) Section R111.3 "Authority to disconnect service utilities" is amended to read as follows: The building official shall have the authority to authorize disconnection of utility of service to the building, structure or system regulated by this code and the referenced codes and standards set forth in Section 30-721, LCMC 1997, as amended, in case of emergency where necessary to eliminate an immediate hazard to life or property or when such utility connection has been made without the approval required by Section R111.1 or R111.2. The building official shall notify the service utility, and wherever possible the owner and occupant of the building, structure, or service system of the decision to disconnect prior to taking such action. If not notified prior to disconnecting, the owner or occupant of the building, structure, or system shall be notified in writing, as soon as practical thereafter. (9) Section R112 "Board of Appeals" exclude in its entirety and see Chapter 30, LCMC 1997, as amended. (10) [Table R301.2(l).] TABLE R301.2(1) CLIMATE AND GEOGRAPHIC DESIGN CRITERIA Ground Snow Load | Wind Design | Seismic Design Category | Subject To Damage From 5 psf | Speed (mph) | Topographic Effects | Wind-borne debris zone | C | Weathering | Frost Line Depth | Termite 115 | No | No | Negligible | 6" | Moderate—Heavy Winter Design Temp | Ice Barrier Underlayment | Flood Hazard | Air Freezing Index | Mean Annual Temp 18 | No | See flood map | 134 | 58.3 (11) Section R318 "Protection Against Termites" is amended to read "Protection Against Termites and Pests" and further amended as follows: R318.3 "Barriers" See the IRC and add the following to the end of the section: All penetrations within a slab on grade foundation shall be sealed in a manner to prevent the infestation of termites or other pests to include vermin into the interior of the structure. (12) Section R319 "Site Addresses" exclude in its entirety and see Chapter 30, LCMC 1997, as amended. (C) 2018 International Energy Conservation Code. The International Energy Conservation Code adopted by reference is amended, altered and changed as follows: (1) Section 103 "Construction Documents" exclude in its entirety and see Chapter 30, LCMC 1997, as amended. (2) Section 105 "Inspections" exclude in its entirety and see Chapter 30, LCMC 1997, as amended. (3) Section 109 "Board of Appeals" exclude in its entirety and see Chapter 30, LCMC 1997, as amended. (D) 2021 International Existing Building Code. The International Existing Building Code adopted by reference is amended, altered and changed as follows: (1) Section 103 "Code Compliance Agency" exclude in its entirety and see Chapter 30, LCMC 1997, as amended. (2) Section 105 "Permits" exclude in its entirety and see Chapter 30, LCMC 1997, as amended. (3) Section 106 "Construction Documents" exclude in its entirety and see Chapter 30, LCMC 1997, as amended. (4) Section 109 "Inspections" exclude in its entirety and see Chapter 30, LCMC 1997, as amended. (5) Section R111.3 "Authority to disconnect service utilities" is amended to read as follows: The building official shall have the authority to authorize disconnection of utility of service to the building, structure or system regulated by this code and the referenced codes and standards set forth in Section 30-721, LCMC 1997, as amended, in case of emergency where necessary to eliminate an immediate hazard to life or property or when such utility connection has been made without the approval required by Section R111.1 or R111.2. The building official shall notify the service utility, and wherever possible the owner and occupant of the building, structure, or service system of the decision to disconnect prior to taking such action. If not notified prior to disconnecting, the owner or occupant of the building, structure, or system shall be notified in writing, as soon as practical thereafter. (6) Section 112 "Means of Appeals" exclude in its entirety and see Chapter 30, LCMC 1997, as amended. (7) Add Section 1201.1.1 "Buildings of Historic Value." Buildings constructed in the Las Cruces Downtown Tax Increment Development District and Amador Proximo area prior to January 1, 1970 shall be considered buildings of historic value to the City of Las Cruces. These buildings shall qualify for all exceptions and preservation protocols established by this Chapter. (E) 2021 Uniform Plumbing Code. The Uniform Plumbing Code adopted by reference is amended, altered and changed as follows: (1) Section 104.0 "Permits" exclude in its entirety and see Chapter 30, LCMC 1997, as amended. (2) Section 105.0 "Inspections and Testing" exclude in its entirety and see Chapter 30, LCMC 1997, as amended. (3) Section 106.0 "Violations and Penalties" exclude in its entirety and see Chapter 30, LCMC 1997, as amended. (4) Section 107.0 "Board of Appeals" exclude in its entirety and see Chapter 30, LCMC 1997, as amended. (5) Table 104.5 "Plumbing Permit Fees" exclude in its entirety. (F) 2021 Uniform Mechanical Code. The Uniform Mechanical Code adopted by reference is amended, altered and changed as follows: (1) Section 104.0 "Permits" exclude in its entirety and see Chapter 30, LCMC 1997, as amended. (2) Section 105.0 "Inspections and Testing" exclude in its entirety and see Chapter 30, LCMC 1997, as amended. (3) Section 106.0 "Violations and Penalties" exclude in its entirety and see Chapter 30, LCMC 1997, as amended. (4) Section 107.0 "Board of Appeals" exclude in its entirety and see Chapter 30, LCMC 1997, as amended. (5) Table 104.5 "Mechanical Permit Fees" exclude in its entirety. (G) 2012 Uniform Swimming Pool, Spa & Hot Tub Code. The Uniform Swimming Pool, Spa & Hot Tub Code adopted by reference is amended, altered and changed as follows: (1) Section 104.0 "Permits" exclude in its entirety and see Chapter 30, LCMC 1997, as amended. (2) Section 105.0 "Inspections and Testing" exclude in its entirety and see Chapter 30, LCMC 1997, as amended. (3) Section 106.0 "Violations and Penalties" exclude in its entirety and see Chapter 30, LCMC 1997, as amended. (4) Section 107.0 "Board of Appeals" exclude in its entirety and see Chapter 30, LCMC 1997, as amended. (5) Table 104.5 "Swimming Pool, Spa and Hot Tub Permit Fees" exclude in its entirety. (H) 2012 Uniform Solar Energy Code. The Uniform Solar Energy Code adopted by reference is amended, altered and changed as follows: (1) Section 104.0 "Permits" exclude in its entirety and see Chapter 30, LCMC 1997, as amended. (2) Section 105.0 "Inspections and Testing" exclude in its entirety and see Chapter 30, LCMC 1997, as amended. (3) Section 106.0 "Violations and Penalties" exclude in its entirety and see Chapter 30, LCMC 1997, as amended. (4) Section 107.0 "Board of Appeals" exclude in its entirety and see Chapter 30 LCMC, 1997 as amended. (5) Table 104.5 "Solar Permit Fees" exclude in its entirety. (I) 2021 International Property Maintenance Code. The International Property Maintenance Code adopted by reference in 30-721,(A) is amended, altered, and changed as follows: (1) Section 102.3 "Application of Other Codes" interpret all references to the International Plumbing Code, the International Mechanical Code, and the International Zoning Code to be references to the corresponding codes adopted in LCMC, 1997 as amended. (2) Section 103 "Code Compliance Agency" exclude in its entirety and see Chapter 30, LCMC 1997, as amended. (3) Section 107 "Means of Appeals" exclude in its entirety and see Chapter 30, LCMC 1997, as amended. (4) Section 108 "Board of Appeals" exclude in its entirety and see Chapter 30, LCMC 1997, as amended. (5) Section 304.14 "Insect Screens" strike the words "During the period from [DATE] to [DATE],". (6) Section 602.3 "Heat Supply" replace the first [DATE] with November 1 and the second [DATE] with April 1. (7) Section 602.4 "Occupiable Work Spaces" replace the first [DATE] with November 1 and the second [DATE] with April 1. (8) Appendix A "Boarding Standard" is hereby adopted with this rule.

(Ord. No. 2478, § I, 11-17-08; Ord. No. 2667, § I(exh. A), 10-1-12; Ord. No. 2803, § I, 1-17-17; Ord. No. 2968, § (I)(Att. A), 4-19-21; Ord. No. 3050, § (I)(Exh. A), 11-20-23)

Ask a question about Las Cruces law

Corpus searches the Las Cruces sections it holds and shows the ones that match, with their citations. Free, no sign-in.