Sec. 32-410. - Street lighting procedures.

The purpose of this section is to establish uniform guidelines and rules for street lighting based on the need to provide for and to improve public safety on all streets open to traffic in the City of Las Cruces. (1) General. a. Street lighting can provide safety, security and convenience. However, street lights are expensive to install and maintain and use significant amounts of energy. Energy savings cannot be justified when the trade-off impacts reduced pedestrian or vehicle safety. Convenience, as the sole justification for lighting, may have to be sacrificed to energy conservation, especially in low density settings. To conserve energy, street and multi-use path lighting should be selected to have a high illuminating efficiency, and to provide no more illumination than necessary. b. The guidelines for street lighting designs, area lighting for recreational facilities, and area with high density nighttime activities shall be based on the minimum surface lighting requirements, as recommended by the Illuminating Engineering Society and International Commission on Illumination. c. Any request to relocate an existing city-owned street light must be pre-approved by the city's traffic engineer prior to construction, and will be relocated at the requesters' expense. All electrical work shall be performed by a journeyman electrician licensed in the State of New Mexico working under a New Mexico licensed electrical contractor. All work shall comply with the City of Las Cruces standards, NEC and MUTCD, and shall be coordinated with the City of Las Cruces Traffic Engineering section. (2) General guidelines. a. Street lighting and multi-use path lighting should be located and mounted to prevent light shining upon residential windows, or into the eyes of drivers, pedestrians and bicyclists. b. Street lighting fixtures shall be designed and installed to comply with the City of Las Cruces Lighting Ordinance. (3) Authority. All lighting designs, pole designs, luminaire designs, and location of poles for all street lighting shall be considered for approval by the city traffic engineer. (4) Underground light circuits for subdivisions. a. In existing subdivisions where all utilities are presently placed underground, and no street lights exist, the City of Las Cruces is responsible for installation of underground street light circuits. b. In new subdivisions, all street lighting shall be installed by the developer concurrently with other associated infrastructure improvements. c. In subdivisions where utilities exist overhead and the property owners choose to place these overhead utilities underground, the property owners will be responsible for underground street light circuit installation. d. In new subdivisions under development within the City of Las Cruces, all street light circuits are to be placed underground. e. All new street lights and associated components shall meet City of Las Cruces lighting specifications. f. Any existing street lighting systems annexed into the City of Las Cruces shall be subject to review for compliance with applicable electrical standards. Failure to meet the requirements of those standards could result in possible condemnation; and lighting which does not meet the standards may be scheduled to be replaced with City of Las Cruces standard street lights as funds become available. (5) Warrants for street lights. a. Limited access facilities. 1. The City of Las Cruces shall be responsible for lighting major streets going over or under a freeway that has been approved by the City of Las Cruces. The City of Las Cruces shall pay the monthly power bill for these lights. 2. The City of Las Cruces is not responsible for necessary lighting of structures or interchanges intersecting with local streets. 3. The City of Las Cruces may install street lights at the intersection of local streets with frontage roads. The freeway frontage road is deemed to terminate at its approach to an off-ramp and begin at its connection to an on-ramp. b. Arterial streets. 1. Street lighting may be installed along arterial streets when traffic volumes, nighttime crashes, nighttime pedestrian use, and/or roadway hazards show a need for improved lighting. 2. Minimum warrant considerations for arterial streets would be an average daily traffic in excess of 10,000 vehicles, and an 85th percentile speed of 40 miles per hour, or greater based on an engineering study. c. Collector streets. 1. Street lighting may be installed along collector streets when traffic volumes, nighttime crashes, nighttime pedestrian use, and/or roadway hazards show a need for improved lighting. 2. Minimum warrant considerations for collector streets would be an average daily traffic in excess of 5,000 vehicles, and an 85th percentile speed of 35 miles per hour or greater, based on an engineering study. (6) Mid-block street lighting. a. Mid-block street lighting may be installed bordering schools, parks, large community centers, churches, housing projects and other civic facilities where a study demonstrates a need and the location satisfies the requirements of this section. b. Residential mid-block lighting may be installed upon petition of owners of property adjacent to the proposed site for a distance of approximately 250 feet each side of the proposed light. c. Residential mid-block lighting shall be spaced at an average distance of 400 feet apart, but not less than 250 feet, to provide an acceptable light level as defined by the Illuminating Engineering Society. d. In new subdivisions, all mid-block lighting shall be installed concurrently by the developer with other improvements. (7) Street lighting spacing. a. Local streets: Lighting will be on one side only. Average spacing will be generally 250—400 feet using high pressure sodium lighting, light emitting diodes (LEDs) or other preapproved lamp type. b. Collector: Lighting will be installed on both sides preferably using staggered spacing (spacing which alternates spacing pattern relative to each side of the street). Spacing will be 250—300 feet using high pressure sodium lighting. If another lamp type is proposed, i.e., light emitting diodes (LEDs), metal halide, etc., a lighting design showing IES accepted average illumination levels must be provided. c. Arterial: Lighting will be installed on both sides using staggered spacing. Spacing on each side will be 250—300 feet using high pressure sodium lighting. If another lamp type is proposed, i.e., light emitting diodes (LEDs), metal halide, etc., a lighting design showing IES accepted average illumination levels must be provided. (8) Street lighting location. a. Improved streets. 1. Consideration must be given to the effect pole placements have on abutting properties. In view of this, the city will make a reasonable concession in a lighting pattern, to avoid placing a pole at a point where it would have a detrimental effect on the abutting property. The city's intent is to focus such concessions primarily on residential properties. In most cases, the pole should be located adjacent to the property line but more importantly lateral placement should conform to the specifications of both street light pole and light head design. 2. Once the permit to use the right-of-way is issued, adherence to approved pole locations is expected. Exceptions are hereby granted for longitudinal shifts up to +/- ten feet, measured parallel to the roadway, where unforeseen underground obstructions are encountered at the time of construction, providing such a shift does not interfere with driveways. 3. Street lighting may be installed on a cul-de-sac street/local street intersection if the center of the radius of cul-de-sac to centerline of intersecting local street is greater than 300 feet. When this condition is met, the street light is considered as an intersection light. If the distance described above is less than 300 feet, the intersection of the cul-de-sac with the local street shall be considered a mid-block location for street lighting purposes. The placement of a street light at the end of the cul-de-sac shall be treated as a mid-block light. 4. Street light placement shall not interfere with pedestrian use of the ADA ramps, sidewalks, driveways, multi-use paths, or utility infrastructure. A 36-inch minimum width must be maintained free and clear of all obstructions on all sidewalks. b. New street construction. 1. Two sets of drawings of proposed street construction shall be furnished to the city's community development department through the building permit application process for the purpose of locating street lights. One set of drawings, showing street light locations and power sources, shall be submitted to El Paso Electric Company by subdivision developer, along with installation information and instructions. El Paso Electric Company will provide the city with one set of drawings showing the proposed construction. All efforts will be made to avoid conflicts and duplications, and to coordinate construction efforts. 2. Preliminary plans for local and collector streets will show an accurate survey tie to all poles (i.e., stationing and offsets) and plans for new construction should show utility easements. 3. All plans will be reviewed by the city for proposed paving width and alignment, prior to submittal to the individual utility companies. c. Company-initiated construction. If a utility company wants to make a change in a pole location, reference should be made to station numbers on the project plans. All poles, both existing and proposed, shall be shown on plans. Existing poles which are to remain shall be noted. Standard utility symbols shall be applied to denote poles existing, proposed, or to be removed. (9) Street light location at intersections. a. The most important aspect of one-side lighting design is to light the intersections with the desired pole location behind the sidewalk at the center of curve at the corner radius. In an effort to achieve reasonable uniformity, deviations away from the center of curve may be permitted up to 15 feet. This applies to intersections on major streets and minor locals. b. All intersections within the city with curb, gutter and paved street may be lighted, when warranted. (10) Street light replacement and relocation. The following policy is to establish uniform guidelines, and is not intended to supersede or conflict with any provisions of the existing franchise agreement between the El Paso Electric Company and the City of Las Cruces, New Mexico, Dona Ana County. Arterial or collector streets: a. Poles will be relocated to the standard utility location behind proposed or existing sidewalk, where normal right-of-way exists. Desired exception to standard location is to be requested on a case by case basis. b. Where a pole line has been established behind the curb face, and it is necessary for one or two poles be relocated, the city will not require these poles to be placed behind the sidewalk area if ADA requirements can be accommodated or maintained. c. When transmission or distribution facilities are installed on major or collector streets, consideration should be given to spacing the poles to accommodate future street lights. Poles located at intersections should be located so as to allow for future street lights. Poles located at intersections should be located so as to allow for future traffic control devices. Along collector and residential streets where residences or building fronts do not face the street and where poles for new or reconstructed transmission or major distribution lines can be spaced from alley to alley or rear property (future or existing), intersection street lights may be located or relocated at an intersection corner on the opposite side of the street from the distribution line, in order to improve the entire appearance of the residential area. (11) Street light procedures for new subdivisions. a. Preliminary review. The developer, or a representative, shall submit to the transportation department, streets and traffic operations section a master utility plan of a proposed subdivision, showing the electrical utility location runs and service points, either underground or above ground. Also, the master utility plan shall contain location of all utility lines (gas, water, sewer, fire hydrants, street lighting, etc.). Also, show location, botanical and common name, and mature size of trees and shrubs in the parkways and medians to be retained as part of the final parkway and median landscape plan. The transportation department will review the plan for street light locations, and connecting conduit runs to electrical service points. The plan shall be returned to the developer with any comments, for review by the developer's registered New Mexico professional engineer. Upon satisfactory acceptance of the changes by city staff, said changes then shall be incorporated into the construction plans. b. Developer responsibility. 1. If the developer, upon approval of the subdivision plat, elects to indemnify the improvements, he shall include the street lighting in the indemnity agreement. If the developer elects to proceed with the installation of the improvements without an indemnity agreement, the city shall hold the subdivision plat. In either case, the building permit will be issued based on the approved plans, and the developer's portion of the street lighting will be inspected as part of the roadway improvements. 2. The developer shall be required to construct the entire street light system within the local street system as well as on arterials and collectors associated with the development of the subdivision, complete in place. Costs associated with installing light standards/luminares, wiring, and service meters associated with lighting on designated collectors or arterials as part of the new development will be shared equally between developer and the City of Las Cruces. This includes, but is not limited to, all underground connecting conduits, wires, concrete foundations, poles, luminaries, fuses, fuse holders, ground rods, pull boxes, electrical service and controls. All street lights and associated components shall comply with the City of Las Cruces traffic standards and applicable electrical codes. All electrical work shall be performed by a journeyman electrician licensed in the State of New Mexico working under a New Mexico licensed electrical contractor. Energizing flat-rated street lighting systems will be the responsibility of the City of Las Cruces as demand warrants based primarily on number of occupied homes within the subdivision. c. City of Las Cruces transportation/street and traffic operations' responsibility. Upon request from the developer, the city traffic engineer shall provide the bolt circle template for street light foundations, as shown on the approved construction drawings. d. Contractor/developer information contact. For information concerning the below items, contractor is to contact the subdivision's designated public works project manager who will in turn consult with transportation department/streets/traffic operations personnel, as needed: 1. Information concerning design specifications. 2. Any conflict of street light locations, requiring relocation as a solution. 3. Any changes or rerouting of conduit runs. 4. Request for additional street lights, within the scope of the City of Las Cruces Outdoor Lighting Ordinance. 5. Request to omit a street light, as shown on the plans. 6. All other items concerning street lights which are not shown above. (12) Joint use of underground trench. Joint use of a trench for the installation of electrical service by El Paso Electric Company, or for street light circuits, is acceptable when approved by the city public works department, transportation department, and El Paso Electric Company.

(Ord. No. 2663, § I(exh. A), 9-4-12)

Ask a question about Las Cruces law

Corpus searches the Las Cruces sections it holds and shows the ones that match, with their citations. Free, no sign-in.