§ 34-104 — Standards for areas of shallow flooding (AO/AH zones)

Municipal Code of the City of Las Cruces, New Mexico (Supp. No. 34: codified through Ordinance No. 3114, adopted June 1, 2026) · Las Cruces Development Code § 34-104

Corpus is an independent public-information project, not the official City of Las Cruces website. Stable reference: corpuslaw.us/code/0d57de19-8822-4953-bd68-0a08d5b87f76

Sec. 34-104. - Standards for areas of shallow flooding (AO/AH zones).

Located within the area of special flood hazard as established in section 34-37 are areas designated as shallow flooding. These areas have special flood hazards associated with base flood depths of one to three feet where a clearly defined channel does not exist and where the path of flooding is unpredictable and where velocity flow may be evident. Such flooding is characterized by ponding or sheet flow; therefore, the following apply to AO and AH zones: (1) All new construction and substantial improvements of residential structures shall have the lowest floor, including basement, elevated above the highest adjacent grade at least as high as the depth number specified in feet on the community's FIRM plus one foot of freeboard (at least three feet if no depth number is specified). (2) All new construction and substantial improvements of nonresidential structures shall: (a) Have the lowest floor, including basement, elevated above the highest adjacent grade at least as high as the depth number specified in feet on the community's FIRM plus one foot of freeboard (at least three feet if no depth number is specified); or (b) Together with attendant utility and sanitary facilities, be designed so that below the base flood level plus one foot of freeboard the structure is watertight with walls substantially impermeable to the passage of water and with structural components having the capability of resisting hydrostatic and hydrodynamic loads of effects of buoyancy. (3) A registered professional engineer or architect shall submit a certification to the floodplain administrator that the standards of this section, as proposed in subsection 34-73(1)(a), are satisfied. (4) Adequate drainage paths around structures on slopes shall be required to guide floodwaters around and away from proposed structures.

(Ord. No. 2785, § II(Exh. B), 7-5-16; Ord. No. 3051, § (I)(Exh. A), 11-20-23)

Ask a question about Las Cruces law

Corpus searches the Las Cruces sections it holds and shows the ones that match, with their citations. Free, no sign-in.