10-4.6 - Fire and explosive hazards.

A. For the purpose of this subsection: Closed cup flash point means the temperature at which a liquid sample produces sufficient vapor to flash but not to ignite when in contact with a flame in a closed cup tester, such as Pensky-Martens, Tagliabue or other standard test equipment. Flammable or explosive materials means materials which produce flammable or explosive gases or vapors under ordinary temperature conditions, including liquids with a closed cup flash point of less than one hundred five degrees Fahrenheit (105°F). Free-burning materials means materials which burn actively and easily support combustion. Intense-burning materials means materials which have low ignition temperature, a high rate of burning and create great heat. Moderate-burning materials means materials which in themselves support combustion and are consumed slowly as they burn. Original sealed containers means containers with a capacity of not more than fifty-five (55) gallons. Slow-burning materials means materials which will not ignite or actively support combustion during an explosion for five (5) minutes to a temperature of twelve hundred degrees Fahrenheit (1,200°F), and, therefore, do not constitute an active fuel. B. Regulations and standards in an I-1 and I-2 district are as follows: (1) Storage, utilization or manufacture of solid materials or products including incombustible to moderate-burning is permitted; (2) Storage, utilization or manufacture of solid materials or products including free-burning and intense-burning is permitted; provided, that such materials or products shall be stored, utilized or manufactured within completely enclosed buildings having incombustible walls and protected throughout by an automatic fire extinguishing system; (3) The storage, utilization or manufacture of flammable liquids, or materials which produce flammable or explosive vapors or gases shall be permitted in accordance with the following table, exclusive of storage of finished products in original sealed containers, which shall be unrestricted; (4) When flammable gases are stored, utilized or manufactured and measured in cubic feet, the quantity in cubic feet (STP) permitted shall not exceed three hundred (300) times the quantities as listed below where the factor three hundred (300) is the volume in cubic feet occupied by one (1) gallon of the liquids. Total Capacity of Flammable Materials Permitted (in gallons) I-1 District Industries Engaged in Storage Only | Aboveground | Underground Materials with closed cup flash point over 187°F | Prohibited | 100,000 Flash point 105°F to 187°F | Prohibited | 40,000 Flash point under 105°F | Prohibited | 20,000 Industries Engaged in Utilization and Manufacture of Flammable Materials Materials with closed cup flash point over 187°F | 50,000 | 100,000 Flash point 105°F to 187°F | 20,000 | 40,000 Flash point under 105°F | 5,000 | 10,000 I-2 District Unrestricted; provided that storage, handling and use shall be in accordance with the Flammable Liquids Code of the city.

(Ord. #1962-19, § 28-5; Code 1973, § 36-348; SFCC 1981, § 3-31-6)

Ask a question about Santa Fe law

Corpus searches the Santa Fe sections it holds and shows the ones that match, with their citations. Free, no sign-in.