For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 18.04.105 — Tree Protection

Reno Administrative Code, City of Reno, Nevada (Supp. No. 65, Update 1: codified through Ordinance No. 6740, adopted May 6, 2026) · Reno Annexation and Land Development Code § 18.04.105

Corpus is an independent public-information project, not the official City of Reno website. Stable reference: corpuslaw.us/code/56b4f31b-f15b-4536-a5f3-2c5c992e69da

18.04.105 - Tree Protection

(a) Applicability This section's tree protection standards apply to all new construction and land-disturbing activity subject to City requirements for a grading or building permit, where the Administrator determines that the construction or land-disturbing activity is expected to adversely affect mature healthy trees on the site. Such determination shall be made prior to or concurrent with an application for a grading or building permit. (b) Preserved Tree Criteria A tree shall be considered "preserved" only if a minimum of 75 percent of the critical root zone is maintained at undisturbed natural grade and no more than 25 percent of the canopy is removed due to building encroachment. (c) Tree Credits Existing mature, healthy trees that are preserved along public rights-of-way or in the front yard may be eligible for a credit toward the total tree requirements stated in Section 18.04.809(a) or in the street tree requirements stated in Section 18.04.804. Eligibility for tree credits shall be based on size and condition of the existing trees as determined by the Urban Forester at the time of application for a building permit. The tree credit shall be calculated by dividing the preserved tree diameter by 2.5. The tree credit may not exceed 30 percent of the required number of trees on the lot. The Administrator shall approve the credit. (d) Replacement of Trees/Penalty for Removal Where existing mature, healthy trees, as determined by the Administrator in consultation with the Urban Forester, are removed along public rights-of-way or in the front yard as a result of any construction, they shall be replaced based on the size of the tree, with deciduous trees of a minimum caliper of 2 ½ inches and evergreen trees with a minimum height of ten feet. The maximum tree penalty for this section is 30 percent. Replacement trees required under this section shall count toward the minimum number of trees required elsewhere in this chapter. (e) Tree Mitigation Plan A tree preservation plan shall be provided by an arborist where construction is expected to adversely impact mature healthy trees. Unless otherwise approved in writing by the Urban Forester, the following procedures shall be followed on all construction projects: (1) Tree Flagging All protected trees on the subject property within 50 feet of a construction area or surface improvements, such as driveways and walks, shall be flagged with bright fluorescent orange vinyl tape wrapped around the main trunk at a height of four feet or more, so that the tape is visible to workers operating construction equipment. (2) Open Space Flagging All trees or groups of trees within areas intended to be saved as open space shall be enclosed with fluorescent orange tape along all areas of possible access or intrusion by construction equipment. Tape shall be supported at a minimum of 25-foot intervals by wrapping trees or utilizing another approved method. Access for the purposes of clearing underbrush is allowed outside of riparian zones. (3) Protective Fencing In those situations where a protected tree is so close to the construction area that construction equipment will infringe on the root system, a protective fence may be required between the tree and the construction activity. See Figure 4-1, below. [image omitted; see the official code] Figure 4-1: Protective Fencing for Trees (4) Bark Protection In situations where a protected tree remains in the immediate area of intended construction, the tree shall be protected by enclosing the entire circumference of the tree with two-inch by four-inch lumber encircled with wire or other means that do not damage the tree. This will protect the bark of the tree against incidental contact by large construction equipment. (f) Prohibited Activities Adjacent to Trees The following activities shall be prohibited within the limits of the critical root zone of any protected tree, subject to the requirements of this ordinance: (1) Material Storage No materials intended for use in construction, or waste materials accumulated due to excavation or demolition, shall be placed within the limits of the critical root zone of any protected tree. (2) Equipment Cleaning/Liquid Disposal No equipment shall be cleaned, or other materials or liquids deposited or allowed to flow over land, within the limits of the critical root zone of a protected tree. This includes, without limitation, paint, oil, solvents, asphalt, concrete, mortar, or similar materials. (3) Tree Attachments No signs, wires, or other attachments other than those of a protective nature shall be attached to any protected tree. (4) Vehicular Traffic No vehicular and/or construction equipment traffic or parking shall take place within the limits of the critical root zone of any protected tree other than on an existing paved street or parking lot. This restriction does not apply to single incident access within the critical root zone for purposes of clearing underbrush, establishing the building pad and associated lot grading, vehicular traffic necessary for routine utility maintenance or emergency restoration of utility service or routine mowing operations. (5) Grade Changes No grade changes over two inches (cut or fill) shall be allowed within the limits of the critical root zone of any protected tree unless adequate construction methods are utilized which have been approved by the Urban Forester. (g) Permitted Construction Methods (1) Boring Boring of utilities under protected trees may be required in certain circumstances. When required, the length of the bore shall be at a minimum the width of the critical root zone and shall be at a minimum depth of 48 inches. (2) Grade Change Grade changes within the critical root zone of a protected tree should not exceed two inches. If more than 25 percent of the critical root zone is disturbed by trenching or a grade change greater than two inches, the applicant may be required to prune the root zone or tree canopy in accordance with industry standards, or to take some other mitigative measure to help preserve the health of the tree. (3) Trenching All trenching shall be designed to avoid crossing the critical root zone of any protected tree. (4) Root Pruning All roots two inches or larger in diameter that are exposed because of trenching or other excavation, shall be cut off and covered with pruning compound within two hours of initial exposure.

Ask a question about Reno law

Corpus searches the Reno sections it holds and shows the ones that match, with their citations. Free, no sign-in.