§ 13.30.020 — Plumbing fixture unit standards

Code of Ordinances of the City of Sparks, Nevada (Codified through Ordinance No. 2676, adopted July 27, 2026 (Supp. No. 25)) · Sparks Code of Ordinances § 13.30.020

Corpus is an independent public-information project, not the official City of Sparks website. Stable reference: corpuslaw.us/code/01df9c41-efc0-4384-9871-71f9bfa3f5c8

Section 13.30.020 - Plumbing fixture unit standards.

All plumbing fixture units must meet the following design standards: A. Toilets and water closets discharge shall not exceed three and one-half (3.5) gallons per flush. B. Urinals discharge shall not exceed one and one-half (1.5) gallons per flush. C. Shower heads discharge shall not exceed three and one-half (3.5) gallons per minute under working pressure. Orifices may be used to reduce flow. D. No fixture shall be allowed that has a continuous flow of water of a constant or automatic nature. E. Grease, interceptors and sand/oil separators shall be constructed to prevent any bypass of matter prohibited in the wastewater system. Grease interceptors shall be a minimum capacity of seven hundred fifty (750) gallons and shall be sized using the 2003 Uniform Plumbing Code Appendix H (Table H-1) sizing criteria. Grease traps are prohibited unless approved by the public works director. Sand/oil separators shall have a minimum capacity of one thousand (1,000) gallons except when otherwise required by the public works director. F. A common grease interceptor, defined as an interceptor accepting wastewater from more than one (1) sewer user must be approved by the public works director. The owner of the premises connected to the wastewater facilities shall maintain the common grease interceptor. The owner, according to the records on file with the office of the county assessor, is responsible for maintaining the common grease interceptor on the schedule outlined in the environmental control permit issued by the public works director. G. Trash enclosures containing a grease rendering receptacle shall include a trench drain connected to the sanitary sewer. Location of the trench drain shall be determined by the public works director. H. Facilities using water for cooling shall not discharge the cooling water to the wastewater system or storm drain system. I. Industrial/commercial process water shall be pretreated, if necessary, to meet discharge requirements of Chapter 13.36 of this title. If process water can be recirculated or reused, equipment shall be installed to accomplish the recirculation or reuse. TABLE H-1 Sizing of Grease Interceptors Number of meals per peak hour 1 | x | Waste flow rate 2 | x | Retention time 3 | x | Storage factor 4 | = | Interceptor size (liquid capacity) 1 | Meals Served at Peak Hour 2 | Waste Flow Rate a. With dishwasher ..... | 6 gallon (22.7L) flow b. Without dishwasher ..... | 5 gallon (18.9L) flow c. Single service kitchen ..... | 2 gallon (7.6L) flow d. Food waste disposer ..... | 1 gallon (3.8L) flow 3 | Retention Times Commercial kitchen waste Dishwasher ..... | 2.5 hours Single service kitchen Single serving ..... | 1.5 hours 4 | Storage factors Fully equipped commercial kitchen ..... | 8-hour operation: 1 16-hour operation: 2 24-hour operation: 3 Single service kitchen ..... | 1.5

(Ord. 2503, Amended, 09/08/2014; Ord. 2420, Amended, 01/26/2009; Ord. 2390, Amended, 02/25/2008; Ord. 2186, Amended, 08/25/2003; Ord. 2059, Amended, 02/28/2000; Ord. 2043, Amended, 11/22/1999; Ord. 1640 § 2, 1989: Ord. 1488 § 1, 1985: Ord. 1283 § 6, (part), 1980)

Ask a question about Sparks law

Corpus searches the Sparks sections it holds and shows the ones that match, with their citations. Free, no sign-in.