§ 15.05.104.2 — Work exempt from permit
Code of Ordinances of the City of Sparks, Nevada (Codified through Ordinance No. 2676, adopted July 27, 2026 (Supp. No. 25)) · Sparks Code of Ordinances § 15.05.104.2
Corpus is an independent public-information project, not the official City of Sparks website. Stable reference: corpuslaw.us/code/56e2e83b-0a11-4410-b58d-8a40bc9ccff8
Section 15.05.104.2 - Work exempt from permit.
Exemptions from permit requirements of this code shall not be deemed to grant authorization for any work to be done in any manner in violation of the provisions of this code or any other laws or ordinances of this jurisdiction. Permits shall not be required for the following: Building: 1. One-story detached accessory structures used as tool and storage sheds, playhouses and similar uses, provided the floor area does not exceed 200 square feet (18.58 m 2 ), does not include electrical, mechanical, or plumbing, and the location is within the setbacks defined in SMC Title 20. 2. Fences not over 30 inches (762 mm) high or residential interior fences not over six feet (1,829 mm) high in rear yards without permanent foundations and not used as swimming pool barriers or as required screening defined in SMC Title 20. 3. Oil derricks. 4. Retaining walls or rockery walls that are not over 48 inches (1,219 mm) in height measured from adjacent grades. Walls must not support a surcharge or impound Class I, II or IIIA liquids. 5. Water tanks supported directly on grade if the capacity does not exceed 5,000 gallons (18,925 L) and the ratio of height to diameter or width does not exceed 2:1. 6. Patios, sidewalks and driveways not more than 30 inches (762 mm) above adjacent grade, and not over any basement or story below, and not part of an accessible route. 7. Painting, papering, tiling, carpeting, cabinets, counter tops and similar finish work. 8. Temporary (not to exceed 180 days) motion picture, television and theater stage sets and scenery. 9. Prefabricated swimming pools accessory to a Group R-3 occupancy that are less than 24 inches (610 mm) deep, do not exceed 5,000 gallons (18,925 L) and are installed entirely above ground. 10. Shade cloth structures constructed for nursery or agricultural purposes, not including service systems. 11. Swings and other playground equipment accessory to detached one- and two-family dwellings. 12. Window awnings supported by an exterior wall that do not project more than 54 inches (1,372 mm) from the exterior wall and do not project more than 24 inches (610 mm) into any setback and do not require additional support; Group R-3 and U occupancies only. 13. Nonfixed and movable fixtures, cases, racks, counters and partitions not over 5 feet 9 inches (1,753 mm) in height. 14. Roofing repair if the roof is less than 100 square feet or still under its one year warranty. 15. Replacing Stucco or Drywall (Not exceeding 100 square feet in area.). 16. Residential door and window replacement when the opening size and location remain the same and meets the adopted energy code requirements. 17. For glass only replacements (in commercial store fronts) in an existing sash and frame, when minor in scope and located in the same elevation. 18. Repair or replacement of fences less than 100 linear feet long with the same material, in the same location and at the same height. 19. Siding applied over existing siding or existing shear wall. 20. Decks not more than 30 inches (762 mm) above grade. 21. Replacement of glazing or replacement of glazing in hazardous locations with safety glazing. 22. Grading under 50 cubic yards (38.23 m 3 ). 23. Membrane-covered frame structures which are not more than 400 square feet (37.21 m 2 ) in area, not more than 15 feet (4,576 mm) in height, meets required setbacks. Installed per the manufacturer's recommendation; with no associated electrical, plumbing, or mechanical, and maintains a minimum clearance of 5 feet (1,524 mm) from other buildings. Electrical: Repairs and maintenance: 1. Minor repair work, including the replacement of lamps or the connection of approved portable electrical equipment to approved permanently installed receptacles. 2. Reinstallations of attachment plug receptacles, but not the outlets therefore. 3. Repair or replacement of branch circuit over-current devices of the required capacity in the same location. 4. Repair or replacement of current-carrying parts of any switch, contactor or control device. 5. Repair or replacement of electrodes or transformers of the same size and capacity for signs or gas tube systems. 6. Repair or replacement of fixed motors, transformers or fixed approved appliances of the same type and rating in the same location. 7. Removal of electrical wire, coax or communication wire. 8. Replacement of light fixtures in single-family and residential accessory structures. Temporary uses: 1. Listed cord and plug connected temporary decorative lighting. 2. Listed temporary construction lighting or wiring. 3. Carnivals and circuses. 4. Installation of any temporary system required for the testing or servicing of electrical equipment or apparatus. 5. Temporary wiring for experimental purposes in suitable experimental laboratories. Electrical wiring, devices and appliances: Electrical wiring, devices, appliances, apparatus or equipment operating at less than 25 volts and not capable of supplying more than 50 watts of energy. Radio and television transmitting stations: The provisions of this code shall not apply to electrical equipment used for radio and television transmissions, but do apply to equipment and wiring for a power supply and the installations of towers and antennas. Public or private utilities: The provisions of this code shall not apply to the installation, alteration or repair of electrical wiring, apparatus or equipment or the generation, transmission, distribution or metering or electrical energy or in the operation of signals or the transmission of intelligence by a public or private utility in the exercise of its function as a serving utility. Gas: 1. Portable heating appliance. 2. Replacement of any minor part that does not alter approval of equipment or make such equipment unsafe. 3. Portable fuel cell appliances that are not connected to a fixed piping system and are not connected to a power grid. Mechanical: 1. Portable heating appliance. 2. Portable ventilation equipment. 3. Portable cooling unit. 4. Steam, hot or chilled water piping within any heating or cooling equipment regulated by this code. 5. Replacement of any part that does not alter approval of equipment or make such equipment unsafe. 6. Portable evaporative cooler. 7. Self-contained refrigeration system containing 10 pounds (5 kg) or less of refrigerant and actuated by motors of 1 horsepower (746 W) or less. Plumbing: 1. The stopping of leaks in drains, water, soil, waste or vent pipe, provided, however, that if any concealed trap, drain pipe, water, soil, waste or vent pipe becomes defective and it becomes necessary to remove and replace the same with new material, such work shall be considered as new work and a permit shall be obtained and inspection made as provided in this code. 2. The clearing of stoppages or the repairing of leaks in pipes, valves or fixtures and the replacement valves and fixtures, provided such repairs or replacements do not involve or require the replacement or rearrangement of any concealed water, soil, waste or vent piping.
(Ord. 2399, Add, 05/12/2008; Ord. No. 2477, § 7, 05/28/2013)
Ask a question about Sparks law
Corpus searches the Sparks sections it holds and shows the ones that match, with their citations. Free, no sign-in.
