Section 17.16.130 - Sewers.

A. Sewage collection or treatment or collection and treatment shall comply with the laws of the state and all local ordinances, be subject to the approval of the public works director and conform to all standards and specifications of the city. B. Sanitary sewer lines shall be designed to have a minimum velocity of two feet per second and a maximum velocity of eight feet per second. No sanitary sewer line other than service laterals shall have a pipe diameter of less than eight inches. Sewer lines shall be installed to provide laterals extending to each lot. Such laterals shall have a minimum pipe diameter of four inches and be constructed to the property line. C. Sewer pipe installed in a traveled way shall have a minimum coverage of three feet or be properly reinforced. D. Maximum distance between manholes shall not exceed three hundred fifty feet unless specifically approved by the public works director. A manhole shall be installed at the end of each sewer line. All sewage facilities shall be installed within the public street right-of-way. Installation of sewage facilities may be permitted in dedicated easements providing readily available access is provided for maintenance purposes. E. Each sheet of sewer plans and profiles submitted to the public works director shall show all required information as herein required. Each plan view shall show lot lines, lot and block numbers, the exact location of the sewer line with reference to property lines, the location of manholes and house laterals, with reference to property lines. Each profile shall show the original ground line flow line of the proposed sewer construction, design line of the proposed street construction, top of manhole elevations, invert elevations, stationing of each manhole, size and type of pipe, percent of grade and exact distance between manholes.

(Ord. 848 § 21, 1971: 1962 Code § 55.290.)

Ask a question about Sparks law

Corpus searches the Sparks sections it holds and shows the ones that match, with their citations. Free, no sign-in.