§ 9.06.085 — Duties of alarm installation companies and monitoring companies
Code of Ordinances of the City of Sparks, Nevada (Codified through Ordinance No. 2676, adopted July 27, 2026 (Supp. No. 25)) · Sparks Code of Ordinances § 9.06.085
Corpus is an independent public-information project, not the official City of Sparks website. Stable reference: corpuslaw.us/code/d3b451c8-3302-4ab0-bec8-727fd60e3faf
Section 9.06.085 - Duties of alarm installation companies and monitoring companies.
A. Upon the installation or activation of an alarm system, the alarm installation company shall distribute to the alarm user information summarizing: (1) The applicable law relating to false alarms, including the potential for penalties and revocation or suspension of an alarm permit; (2) How to prevent false alarms; and (3) How to operate the alarm system. B. Ninety days after the effective date of this ordinance, alarm installation companies shall not program alarm systems so that they are capable of sending one plus duress alarms. Monitoring companies may continue to report one plus duress alarms received from alarm systems programmed with one plus duress alarms installed prior to the effective date of this ordinance. C. After the effective date of this ordinance, alarm installation companies shall install a device to activate a holdup alarm which is either a dual action button or a button with time-delayed activation. D. Ninety days after the effective date of this ordinance, an alarm installation company shall, on new installations, use only alarm control panel(s) which meet ANSI/SIA CP-01- Control Panel Standard - Features for False Alarm Reduction. E. An alarm company shall not use an automatic voice dialer for any alarm system. F. After completion of the installation of an alarm system, an employee of the alarm installation company shall review with the alarm user the customer false alarm prevention checklist or an equivalent checklist approved by the Alarm Administrator. G. A monitoring company shall not make an alarm dispatch request to a burglar alarm signal during the first seven-day "acclimation period" after a burglar alarm system installation. Exceptions to the "acclimation period" of nonresponse can be made by the Police Department in special circumstances, including but not limited to, domestic violence and stalking. H. A monitoring Company shall: (1) Report alarm signals by using telephone numbers designated by the Alarm Administrator; (2) Employ Enhanced Call Verification by attempting to verify by telephone the validity of every alarm signal, except a duress or holdup alarm activation, before requesting an officer's response to an alarm system signal. Verification before requesting officer dispatch also requires that a second telephone call be made to a different phone number if the first attempt fails to reach an alarm user who can determine whether an alarm signal is valid. Names and telephone numbers of those persons contacted or attempted to be contacted must be provided to the Alarm Administrator or Police Department upon request; (3) Communicate alarm dispatch requests to the Police Department in a manner and form determined by the Alarm Administrator; (4) Communicate cancellations to the Police Department in a manner and form determined by the Alarm Administrator; (5) Ensure that all alarm users of alarm systems equipped with a duress, holdup or panic alarm are given adequate training as to the proper use of the alarm. (6) Communicate any available information (north, south, front, back, floor, etc.) about the location of an alarm signal as part of an alarm dispatch request; (7) Communicate the type of alarm activation (silent or audible, interior or perimeter), if available, on any alarm dispatch request. (8) Notify the Police Department Communications Station (Dispatch) of any alarm site that it knows, or reasonably should know, is fitted with a protective-reactive device. During any alarm at such a site, a responsible party must be contacted and confirm that he or she will respond to the alarm site to disarm the device. In all cases where a protective-reactive device is present at an alarm site, the police dispatch request shall include a warning for officers not to enter the alarm site until the responsible party is present and has disarmed the device. (9) Prior to making an alarm dispatch request, attempt to notify the alarm user to send a responsible party to the alarm site, in order to: (a) Deactivate an alarm system; (b) Provide access to the alarm site; and/or (c) Provide alternative security for the alarm site. (10) After an alarm dispatch request, promptly advise the Police Department if the monitoring company knows that the alarm user or a responsible party is on the way to the alarm site; (11) Each monitoring company must maintain for a period of at least one year after the date of an alarm dispatch request, all records relating to the alarm dispatch request. Records must include the name, address and telephone number of the alarm user, each alarm system zone activated, the time of alarm dispatch request and evidence of all attempts to verify. The Alarm Administrator may request copies of such records for any individual alarm user. If the request is made within 60 days after an alarm dispatch request, the monitoring company shall furnish requested records within three business days after receiving the request. If the records are requested between 60 days and 1 year after an alarm dispatch request, the monitoring company shall furnish the requested records within 30 days after receiving the request. (12) Each monitoring company shall, upon request, immediately provide the Police Department with the names and phone numbers of the alarm user's emergency contacts at the time of each alarm dispatch request. I. Existing Accounts. On or before the first day of January of each year, an alarm installation company or monitoring company shall provide the Alarm Administrator with a complete list of active customers, to assist the alarm administrator with creating and maintaining tracking data. The customer information must be provided in a format the alarm company is capable of producing and must include the following: 1. Customer name; 2. Alarm site address; and 3. Alarm company license number. J. Purchased Accounts. An alarm installation company or monitoring company that purchases any alarm system account from another person shall notify the Alarm Administrator of such purchase and shall provide to the Alarm Administrator a complete list of the acquired customers, in a format the alarm company is capable of producing, that includes the following: 1. Customer name; 2. Alarm site address; and 3. Alarm company license number. K. The customer lists described in subsections I and J of this section are proprietary and confidential information and are protected from disclosure pursuant to SMC 9.06.165.
(Ord. 2348, Add, 01/27/2006)
Ask a question about Sparks law
Corpus searches the Sparks sections it holds and shows the ones that match, with their citations. Free, no sign-in.