§ 165-24 — Lighting and other requirements
Code of Ordinances of the City of Buffalo, New York (Code 2026-03-31: eCode360 publication current through the 2026-03-31 codification (imported 2026-11-12)) · Buffalo City Code § 165-24
Corpus is an independent public-information project, not the official City of Buffalo website. Stable reference: corpuslaw.us/code/7243b2d6-15c7-4639-a57c-0893c9b87eff
§ 165-24: Lighting and other requirements.
Every dwelling shall be supplied with electricity and shall meet the following requirements: A. Every habitable room of each dwelling shall contain at least one electrical duplex convenience outlet when the floor area does not exceed 120 square feet. For each additional 100 square feet or any portion thereof, one additional electrical duplex convenience outlet shall be installed. B. Every kitchen or kitchenette shall have a duplex convenience outlet properly installed for the refrigerator and at least one additional duplex convenience outlet for kitchen or kitchenette use; and if over 120 square feet of area, one additional duplex convenience outlet for every additional 100 square feet or portion thereof. C. Every laundry room shall contain at least one duplex convenience outlet. D. Every bathroom shall contain at least one electric light fixture and at least one convenience outlet. In bathrooms only, convenience outlets in wall light fixtures shall meet the requirements of this code. E. An electric light fixture shall be installed in every water closet compartment, laundry room, furnace room and kitchen. F. All wires shall be proper size to supply fixtures and appliances as specified in the Electric Code. Every outlet and fixture in all electrical wiring shall be installed and maintained in an approved manner in accordance with the requirement of generally accepted safety standards of the Electric Code. G. Prohibitions. (1) The use of fragile extruding convenience outlets which extrude more than 1/2 inch from the wall within four feet of floor level is prohibited. (2) The use of fragile extension cord receptacle and plug ends within four feet of the floor is prohibited. (3) The use of extension cords directly beneath floor covering materials or extending through doorways, transoms, walls, ceilings and floors is prohibited. (4) The use of extension cords beyond the recommendation of the Electric Code is also prohibited.
Ask a question about Buffalo law
Corpus searches the Buffalo sections it holds and shows the ones that match, with their citations. Free, no sign-in.