§ 149-25 — Fuel gas
Code of the City of Mount Vernon, New York · Mount Vernon City Code § 149-25
Corpus is an independent public-information project, not the official City of Mount Vernon website. Stable reference: corpuslaw.us/code/b6dfa130-ed68-458e-8c22-275cc173737d
§ 149-25: Fuel gas.
A. General requirements. (1) Fuel gas piping systems shall be installed and maintained so as to remain gastight, safe and operative under conditions of use. (2) Fuel gas piping systems shall provide a supply of gas sufficient to meet the maximum expected demand of the installed gas-burning appliances connected thereto. B. Shutoff valves. (1) Gas piping systems shall have at least one accessible means from the street for shutting off all gas supply, and such means shall be maintained in good operating condition. (2) An easily accessible shutoff valve or cock shall be provided in the piping in close proximity to and ahead of every outlet for gas appliance. C. Service equipment for gas supplied from utility mains. Gas services, gas meters and gas pressure regulators shall be located so that they are protected from damage. D. Refrigerators and ranges. Gas refrigerators and ranges shall be installed with clearance for ventilation and shall be maintained in good operating condition. E. High-pressure gas. Any service connection supplying gas at a pressure in excess of one pound per square inch gauge shall be provided with a device to reduce such pressure to not more than 1/2 pound per square inch gauge prior to entering the meter, except where such service supplies equipment using gas at high pressures. F. Liquefied petroleum gas. (1) Undiluted liquefied petroleum gas in liquid form shall not be conveyed through piping equipment and systems in buildings. (2) Liquefied petroleum gas shall not be vaporized by devices utilizing open flame or open electrical coil. (3) Where two or more containers are installed, connection shall be arranged so that containers can be replaced without shutting off the flow of gas to equipment. (4) Containers shall be designed, stored and located so as not to be a hazard to the premises served or to the surrounding property. (5) Systems shall be provided with safety devices to relieve excessive pressures and shall be arranged so that the discharge terminates at a safe location. (6) Systems shall have at least one accessible means for shutting off the gas. Such means shall be located outside the building and shall be maintained in good operating condition.
Ask a question about Mount Vernon law
Corpus searches the Mount Vernon sections it holds and shows the ones that match, with their citations. Free, no sign-in.