§ 162-5 — Location of containers and regulating equipment

Code of the City of Mount Vernon, New York · Mount Vernon City Code § 162-5

Corpus is an independent public-information project, not the official City of Mount Vernon website. Stable reference: corpuslaw.us/code/83817401-71c9-4f6b-ad5f-883c7b6b3ce6

§ 162-5: Location of containers and regulating equipment.

A. Each individual container shall be located with respect to the nearest building or group of buildings or lot line of adjoining property which may be built upon in accordance with Table 1: Table 1 Minimum Distances Water Capacity per Container(gallons) | Underground Containers(feet) | Aboveground Containers(feet) | Between Aboveground Containers(feet) Less than 125 | 10 | None | None 125 to 250 | 10 | 10 | None 251 to 500 | 10 | 10 | 3 501 to 2,000 | 25 | 25 | 3 2,001 to 30,000 | 50 | 50 | 5 30,001 to 70,000 | 50 | 75 | 1/4 of sum of diameters 70,001 to 90,000 | 50 | 100 | Adjacent containers If the aggregate water capacity of a multicontainer installation at a consumer site is 501 gallons or greater, the minimum distance shall comply with the appropriate portion of this table, applying the aggregate capacity rather than the capacity per container. If more than one installation is made, each installation shall be separated from another installation by at least 25 feet. Do not apply the minimum distances between aboveground containers to such installations. [NOTE: The above distance requirements may be reduced to not less than 10 feet for a single container of 1,200 gallons' water capacity or less, provided that such a container is at least 25 feet from any other liquefied petroleum gas container of more than 125 gallons' water capacity.] B. Containers installed for use shall not be stacked one above the other. C. In cases of bulk storage in heavily populated or congested areas, the authority having jurisdiction shall determine restrictions of individual tank capacity, total storage and distance to line of adjoining property which may be built upon and other reasonable protective methods. [NOTE: Generally, aggregate storage of 2,000 gallons' water capacity or more is considered bulk storage.] D. In industrial installations involving containers of 180,000 gallons' aggregate water capacity or more, where serious mutual exposures between the container and adjacent properties prevail, the authority having jurisdiction may require fire walls or other means of special protection designed and constructed in accordance with good engineering practices. E. In the case of buildings devoted exclusively to gas manufacturing and distributing operations, the above distances may be reduced, provided that in no case shall containers of a water capacity exceeding 500 gallons be located closer than 10 feet to such gas manufacturing and distributing buildings. F. Readily ignitable material, such as weeds and long dry grass, shall be removed within 10 feet of any container. G. The minimum separation between liquefied petroleum gas containers and flammable liquid tanks shall be 20 feet, and the minimum separation between a container and the center line of the dike shall be 10 feet. The foregoing provision shall not apply when liquefied petroleum gas containers of 125 gallons' or less capacity are installed adjacent to Class III flammable liquid tanks of 275 gallons' or less capacity. H. Suitable means shall be taken to prevent the accumulation of flammable liquids under adjacent liquefied petroleum gas containers, such as by diking, diversion curbs or grading. I. When dikes are used with flammable liquid tanks, no liquefied petroleum gas containers shall be located within the diked area.

Ask a question about Mount Vernon law

Corpus searches the Mount Vernon sections it holds and shows the ones that match, with their citations. Free, no sign-in.