§ 218-8 — Construction specifications
Code of the City of Mount Vernon, New York · Mount Vernon City Code § 218-8
Corpus is an independent public-information project, not the official City of Mount Vernon website. Stable reference: corpuslaw.us/code/05860079-2cc2-44d5-950e-1f167b6ec6ca
§ 218-8: Construction specifications.
Shooting ranges wherein firearms are used shall be maintained and constructed in accordance with the following specifications: A. Backstop. The backstop or bullet stop shall be constructed of steel plates at least 3/8 of an inch thick, substantially fastened and reinforced at the seams or butts to form a continuous plate from wall to wall. The plates shall extend from floor to ceiling or at least eight feet above the floor and be mounted at an angle of 45° to the line of fire and floor. No horizontal seams or butts will be permitted to cause dangerous ricochets. If bolts are used for fastenings, they shall be flatheads and the plates countersunk so that bolt heads are flush with the surface of the plates. B. Sand trap. There shall be installed on the floor from wall to wall, directly beneath the entire backstop, a sand trap to catch the bullets deflected from the backstop. The sand shall be either white beach or fine building, at least six inches deep throughout and shall be held in place by means which will not cause dangerous ricochets. C. Firing stalls. There shall be installed at the firing point and parallel to the line of fire, steel plates at least 1/4 of an inch thick, six feet long and at least seven feet high, faced with a fire-retardant, sound-absorbent material at least 1/2 inch thick. These plates shall be spaced at least 36 inches apart to form firing stalls. In the center of each firing stall and at a convenient height from the floor, there shall be installed a wood shelf at least 12 inches wide, to mark the firing point and act as a barrier to prevent participants from entering the range forward of the firing point. Angle iron or the like shall not be used for bracing on the front edge of the partition plates but may be used on the rear edges. D. Target carriers. There shall be installed in each firing stall an electrical or mechanical target carrier capable of transporting the target to and from the firing point to the position where it is to be fired upon. These target carriers are to be constructed so as to present no right-angle surfaces to the marksman which may cause dangerous ricochets. E. Range proper. The range proper must be completely enclosed beyond the firing point and lined with bulletproof material. All surfaces on the range forward of the firing point presenting a right angle to the line of fire, including pipes, columns, etc., shall be properly treated so as to eliminate the possibility of a dangerous ricochet. All electrical wiring in the range proper must be concealed and all electrical wiring for target equipment must be installed behind the firing point. F. Soundproofing. All walls and ceilings shall be faced with satisfactory sound-absorbent material. G. Ventilation. Ventilation shall be installed to exhaust the powder smoke, gases and sand dust from the range away from the marksman, in the direction of the backstop. H. Repairs. Whenever any exposed surface in a shooting range shall show holes or undue wear from being constantly struck by the missiles used, such exposed surface shall be immediately repaired or replaced. I. Regulations of other departments. In addition to the specifications hereinbefore provided, such shooting ranges shall conform in all respects to all health and fire prevention regulations of the City.[1]
Ask a question about Mount Vernon law
Corpus searches the Mount Vernon sections it holds and shows the ones that match, with their citations. Free, no sign-in.