For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 267-19 — List of mixed-use districts

Code of the City of Mount Vernon, New York · Mount Vernon City Code § 267-19

Corpus is an independent public-information project, not the official City of Mount Vernon website. Stable reference: corpuslaw.us/code/85277412-2339-48cb-a817-d21451fc5d6f

§ 267-19: List of mixed-use districts.

A. MX-1 Commercial Corridor District. (1) Purpose. The MX-1 Commercial Corridor District is intended to encourage mixed-use development (a minimum of commercial and/or cultural uses, at street level, and residential uses) that are set close to the sidewalk for a well-defined street wall to activate and support pedestrian activity and the street-level environment and promote the development of a vibrant and pedestrian-oriented commercial corridor. Development standards will be used to repair, stabilize, and revitalize the area's urban fabric which will position the area for concentrated investment, minimize auto-dependency, enhance pedestrian movement, and establish a vibrant streetscape. (2) Boundary. The boundaries of the MX-1 Commercial Corridor District shall be fixed by amendment to the official City Zoning Map as authorized by the City Council. Section, block and lot of all parcels within such district shall be kept on file in the office of the City Clerk. Address | SBL 0 Third Street East | 165.72-4006-09 317 Third Street East | 165.72-4006-10 317 Third Street East | 165.72-4006-11 303 Third Street East | 165.72-4006-12 301 Third Street East | 165.72-4006-13 299 Third Street East | 165.72-4006-14 287 Third Street East | 165.72-4006-15 275 Third Street East | 165.72-4006-16 0 Third Street East | 165.72-4006-17 271 Third Street East | 165.72-4006-18 319 Third Street East | 165.72-4006-30 277 Third Street East | 165.72-4006-33 0 Third Street East | 165.72-4006-34 311 Third Street East | 165.72-4006-36 285 Third Street East | 165.72-4006-37 138 Columbus Avenue South | 165.73-4006-01 397 Third Street East | 165.73-4006-02 389 Third Street East | 165.73-4006-04 325 Third Street East | 165.73-4006-06 323 Third Street East | 165.73-4006-07 315 Third Street East | 165.73-4006-08 56 Haven Avenue | 165.73-4006-22 60 Haven Avenue | 165.73-4006-23 64 Haven Avenue | 165.73-4006-24 0 Haven Avenue | 165.73-4006-25 140 Columbus Avenue South | 165.73-4006-39 403 Third Street East | 165.73-4032-26 185 Columbus Avenue South | 165.73-4032-42 203 Columbus Avenue South | 165.73-4033-14 390 Third Street East | 165.73-4034-01 388 Third Street East | 165.73-4034-44 206 Fulton Avenue South | 165.80-3156-10 208 Fulton Avenue South | 165.80-3156-12 212 Fulton Avenue South | 165.80-3156-13 167 Third Street East | 165.80-3159-14 215 Third Street East | 165.80-4002-09 0 Third Street East | 165.80-4003-12 37 Cooley Place | 165.80-4003-13 31 Cooley Place | 165.80-4003-14 0 Hartford Avenue | 165.80-4005-18 10 Hartford Avenue | 165.80-4005-19 265 Third Street East | 165.80-4006-19 253 Third Street East | 165.80-4006-20 257 Third Street East | 165.80-4006-28 269 Third Street East | 165.80-4006-29 294 Third Street East | 165.80-4034-27 300 Third Street East | 165.80-4034-28 304 Third Street East | 165.80-4034-29 284 Third Street East | 165.80-4035-01 270 Third Street East | 165.80-4035-14 282 Third Street East | 165.80-4035-15 256 Third Street East | 165.80-4036-01 252 Third Street East | 165.80-4036-11 242 Third Street East | 165.80-4037-01 232 Third Street East | 165.80-4037-02 221 Fulton Avenue South | 165.80-4037-11 0 Fulton Avenue South | 165.80-4037-12 206 Third Street East | 165.80-4037-13 212 Third Street East | 165.80-4037-15 240 Third Street East | 165.80-4037-16 222 Third Street East | 165.80-4037-17 316 Third Street East | 165.81-4034-30 318 Third Street East | 165.81-4034-31 0 Chestnut Place | 165.81-4034-40 0 Third Street East | 165.81-4034-42 Figure 1Proposed East Third Street/South Fulton Avenue Rezoning Area [image] (3) List of use regulations. (a) Permitted principal uses. [1] Mixed-use, provided that the ground floor shall consist of one of the permitted or special uses listed below. [2] Municipal uses of the City of Mount Vernon and uses of other governmental agencies as regulated by Article VI, § 267-34. [3] Bakeries, retail. [4] Banks (excluding drive-up window service). [5] Business, professional or governmental offices. [6] Business incubator space. [7] Experiential retail. [8] Health and fitness centers, including ancillary services such as wellness, physical rehabilitation facilities and prevention health education activities. [9] Museums, art galleries, and/or other cultural uses. [10] Business, professional or governmental offices. [11] Office space for physicians, surgeons and dentists. [12] Stores and shops exclusively for sales at retail or the performance of customary personal services. [13] Restaurants. [14] Restaurants, carry-out. [15] Restaurants, fast-food (excluding drive-up window service). [16] Retail laundries or retail dry cleaners. [17] Vocational schools. [18] Community purpose buildings and/or spaces. [19] Youth services. [20] Recreation center. [21] Theaters and/or concert halls. [22] Personal instructional facilities. [23] Churches, mosques, synagogues, or other places of worship. (b) Permitted accessory uses. [1] Uses and structures which are clearly incidental and customarily accessory to the permitted principal use on the lot on which they are located. [2] Office in residence of a professional person and customary home occupations as regulated by Article V, § 267-18. (c) Uses allowed by special permit. [1] Animal hospital. [2] Bars, nightclubs and catering halls. [3] Business and/or trade schools. [4] Day-care centers. [5] Funeral parlors. [6] Hotels or motels. [7] Manufacture and/or assembly of products for retail sale on premises only. [8] Medical and/or dental laboratories. [9] Motor vehicle rental agencies. [10] Nursery schools. [11] Off-street parking facility. [12] Public utility. [13] Universities, colleges and private schools. [14] Wireless telecommunication facilities. [15] Storage facilities. (d) Land uses not listed. [1] In instances where a land use is not listed as a permitted use, accessory use, or the special use and the unlisted use substantially conforms to the purpose of the MX-1 Zoning District and the City's long-range economic strategy, the Commissioner of Planning and Community Development may recommend the use as special use permit to the Planning Board. [2] The Planning Board shall have the authority to issue a special use permit for any unlisted use, provided that: [a] The Commissioner of Planning and Community development recommends the use as a specially permitted use to the Planning Board; [b] The Planning Board approves the Commissioner of Planning and Community Development assessment with regard to the use, while considering the standards set forth in Article VI, § 267-31, of this chapter; [c] The use is classified as a "Type II" action or an "unlisted" action; wherein, a negative declaration is issued pursuant to the State Environmental Quality Review Act ("SEQRA"); [d] The applicant shall demonstrate with documentation that the use complies with all findings of the SEQRA generic environmental impact statement adopted for the MX-1 Zoning District, and will not result in any impacts that exceed the thresholds established therein; and [e] The use receives site plan approval. (4) Allowable building types. The MX-1 Commercial Corridor zone permits mixed-use and nonresidential structure(s). (5) Standards. The following standards are hereby established as the minimum or maximum requirements, as the case may be, but may be made more restrictive where such is determined appropriate by the Planning Board, based upon consideration of the particular circumstances of the individual application, to satisfy the purposes as set forth in Article V, § 267-21, hereof. All new structure(s), including mixed-use buildings or structures or nonresidential buildings or structure(s), and those with significant facade renovation, replacement and/or rehabilitation - defined as replacement or renovation of 35% or more of the facade within the MX-1 Zoning District - shall abide by this chapter. (a) Lot standards. [image] Lot Standards | Tier 1 | Tier 2 | Tier 3 A. Lot width (minimum) | 90 feet | 65 feet | 45 feet B. Lot coverage (maximum) | 90% | 90% | 100% C. Usable open space | 10% | 10% | 0% (b) Building placement and parking setbacks. [image] Building Placement A. | Primary front setback (minimum/maximum) | 2 feet/15 feet B. | Secondary front setback (minimum/maximum) | 2 feet/15 feet C. | Side setback (minimum) | 0 feet Abutting residence lot line (minimum) | 5 feet D. | Rear setback (minimum) | 10 feet Abutting residence lot line (minimum) | 15 feet Parking Setbacks E. | Primary front setback (minimum) Surface parking | 30 feet Structured parking | 30 feet F. | Secondary front setback (minimum) Surface parking | 10 feet Structured parking | 2 feet (c) Height and mass. [image] Tier 1 | Tier 2 | Tier 3 Main Body A. | Building width (maximum) | 200 feet | 200 feet | 200 feet Facade build-out (minimum) Front street | 80% | 80% | 80% Side street | 65% | 65% | 65% B. | Floor plate (max) | 30,000 square feet | 20,000 square feet | 15,000 square feet C. | Building height, stories (minimum) | 3 stories | 3 stories | 2 stories D. | Building height, stories (maximum) | 6 stories | 5 stories | 3 stories Corner height bonusIntersection of 2 collector streets Intersection of collector and local street | See Subsection A(8)(a) | See Subsection A(8)(a) | See Subsection A(8)(a) E. | Ground story height (minimum) | 14 feet | 14 feet | 14 feet F. | Upper story height (minimum) | 10 feet | 10 feet | 10 feet Use and Occupancy Ground story entrance spacing (maximum) | | 30 feet | 30 feet Commercial space depth (minimum) | | 30 feet | 30 feet (d) Activation. [image] Lot on a Corner Facade Composition A. | Ground story fenestration (minimum) | 70% B. | Upper story fenestration (minimum/maximum) | 20%/50% Blank wall (maximum) | 20 feet Use and Occupancy Ground story entrance spacing (maximum) | 30 feet Commercial space depth (minimum) | 30 feet (e) Hardship provision. When an applicant has demonstrated to the satisfaction of the Planning Board that site constraints or financial hardship directly related to the standards described herein makes compliance to said standards infeasible financially or otherwise, and this hardship has not been created by the applicant, the Planning Board may provide a waiver from said standards, with conditions if necessary, when the Planning Board has determined that said waiver: [1] Substantially secures the objectives of the district as articulated in Article V, § 267-19A(1). [2] Will not injure the public health, safety, or welfare. [3] Will not have an adverse impact on the physical, visual, and spatial character of the surrounding area. [4] Will enhance the physical, visual, and spatial character of the streetscape. (6) Density bonus. An applicant may apply to the Planning Board for one or more density bonuses in exchange for providing amenities to the City. (a) The Planning Board may, at its discretion and subject to the standards and considerations set forth below, grant a density bonus for amenity(ies) offered by developers, for structures in the MX-1 Commercial Corridor District according to the maximums below except that the maximum building height shall not exceed a total of eight stories. Tier | Maximum Density Bonus Tier 1 | 2 stories Tier 2 | 3 stories Tier 3 | 5 stories (b) A density bonus may be granted in exchange for an applicant providing one or more of the following amenities equaling, at a minimum, approximately 0.5% of the total development cost of the project, with the Planning Board considering the proportionality of the cost of one or more amenities to the density bonus being considered: [1] Provision, renovation, or rehabilitation of a public open space amenity. By contributing a significant provision, renovation, donation and/or rehabilitation of a public open space amenity, which is reasonably accessible and within relatively close proximity to the development's occupants, to include but not limited to a public park and/or other public open space, a density bonus may be granted. The required 10% usable open space/recreation area for Tier 1 and Tier 2 developments, as a percentage of total lot area, or payment in lieu of open space/recreation area as specified below, shall not count towards this amenity. [2] Historic preservation. Preserving a significant portion of a building(s) or structure(s) identified by the Commissioner of Planning and Community Development as having historical, cultural and/or architectural significance, and approved by the Planning Board. [3] Contribution to non-site-related infrastructure improvements. Non-site-related improvements are considered significant improvements that are not directly needed, required or related to the subject site development but may indirectly improve the area. Infrastructure improvements may include, but are not limited to, significant provision, renovations, creation, donation, installation, improvement and/or rehabilitation of sanitary sewer and stormwater infrastructure (above and beyond the required 3-to-1 inflow and infiltration reduction required in this section), traffic calming measures, specialty pavers or utility covers as part of a district branding, repaving of a street(s), intersection upgrades (including streetlights and crosswalks) and bus shelters. The City Department of Public Works shall provide recommendations to the Planning Board. [4] Provision of alternative off-site parking facilities. By contributing to the creation of an off-site parking facility, above and beyond the off-street parking requirements for the proposed development included in this district, a density bonus may be granted that would provide additional parking proportionate to the size and scope of the project. This may include but is not limited to the creation of a public off-street parking garage, dedicating land for the creation of a public off-street parking facility, payment to a dedicated escrow account managed by the City for the provision of parking in the MX-1 District, or the creation of a privately operated parking facility. [5] Financing of planning study or plan. Finance the preparation of a Neighborhood Plan guiding the development of the MX-1 District in a manner that makes it compatible with surrounding land uses and ensures the sufficient provision of necessary infrastructure to support development within the MX-1 District in the scenario of a full build-out of the MX-1 District, while satisfying the economic and development goals of the City. The financing terms of this Neighborhood Plan are to be approved by the Planning Board. The applicant shall deposit the sum required by the Planning Board into an escrow account to be managed by the City for the City to undertake the preparation of the Neighborhood Plan. If an applicant sufficiently finances said Neighborhood Plan, as determined by the Planning Board, this density bonus shall not be available to any subsequent applicant for the next 15 years. [6] Urban renewal agency contribution. Contributing financially to a fund administered by the Mount Vernon Urban Renewal Agency to finance low-interest home repair loans to property owners located in the MX-1 District, with each contribution being associated with a single issuance of a density bonus. (c) Granting the density bonus. In awarding a bonus for the amenities listed above, the Planning Board shall consider the following criteria: [1] The incentives being proposed and the degree to which the proposed amenity is compatible with the goals and objectives for the MX-1 District and the City's long-range planning strategy. [2] Set forth in the public record, in detail, the amenities to be provided by the applicant, how those amenities further the purposes of the MX-1 District and the City's long-range planning strategies, how they preserve and enhance the aesthetic, environmental and/or historical qualities and features of this district for the benefit and enjoyment of the entire community and otherwise promote the public health, safety and welfare of the community. [3] The associated maintenance schedule and ownership of the proposed amenity(ies). [4] The density bonus can be successfully integrated into the overall building/site design without negatively impacting, detracting and/or severely departing from an appropriate height, scale, mass, size, and shape of the proposed structure(s). [5] The density bonus can be successfully integrated into the overall building/site design without negatively impacting, detracting and/or severely departing from an appropriate height, scale, mass and/or size of the surrounding area. [6] Set forth in the public record, in detail, the relationship between the amenities being provided and the bonus being awarded and shall specify the rationale supporting the proportionality of the amenities to the bonus. The public benefit improvements provided shall be roughly proportional in nature and extent to the bonus granted, and their proportionality shall be demonstrated by the applicant and agreed to by the Planning Board. The cost of the improvements need not equal the value of the benefits granted. The granting or denial of any density bonus shall be solely within the discretion of the Planning Board using the criteria set forth in this section. [7] In the event the Planning Board has denied an exception from the height requirements articulated in Subsection A(5)(e), an application for a zoning variance may be made to the Zoning Board of Appeals to increase the number of stories in excess of the six stories permitted. The Planning Board shall submit a report regarding the application to the Zoning Board of Appeals to assist with its determination within 30 days of said application to the Zoning Board of Appeals being made, and the Zoning Board of Appeals shall consider whether: [a] An undesirable change will be produced in the character of the MX-1 District or surrounding neighborhoods, including to nearby properties, by allowing a structure not compatible with the intensity of the MX-1 District or surrounding neighborhoods. [b] The benefit sought by the applicant can be achieved by some alternative feasible method, including the provision of one of the density bonuses listed herein, in lieu of a variance. [c] The requested variance is substantial in comparison to the heights permitted by right in the MX-1 District, in addition to those heights permitted through density bonuses. [d] The requested variance will have an adverse effect or impact on the physical or environmental conditions in the MX-1 District or surrounding neighborhood, including, but not limited to, the creation of shadows and undue burdens on infrastructure and public services. [e] The alleged difficulty was self-created. (7) Off-street parking space requirements. (a) The total off-street parking required shall be the sum of the requirements for each individual use. A joint use parking agreement, if executed according to the standards set forth below, would allow a reduction in the total requirement for a building or structure. (b) Number of required parking spaces. [1] The minimum number of parking spaces required for the residential component of mixed-use building(s) or structure(s) shall follow: [a] For projects less than 0.70 mile from a Metro North train station as measured from the edge of the development site to the nearest end of the station platform: [i] Studio: 0.75 space per unit. [ii] One-bedroom: 0.95 space per unit. [iii] All other: 1.15 spaces per unit. [b] For projects more than 0.70 mile from a Metro North train station as measured from the edge of the development site to the nearest end of the station platform: [i] Studio: 1.00 space per unit. [ii] One-bedroom: 1.20 spaces per unit. [iii] All other: 1.33 spaces per unit. [c] Calculation of total number of parking spaces shall be rounded to the nearest whole number. [2] The minimum number of parking spaces required for office and commercial/retail space shall be one per every 1,000 square feet of office and commercial/retail space. [3] The minimum number of required parking spaces for all other permitted principal uses and uses allowed by special use permit are as provided in this chapter; except, where not so provided, the parking requirement shall be determined by the Planning Board upon the recommendation of the Commissioner of Planning and Community Development, as part of its site plan review. [4] For mixed-use developments, approval by the Planning Board of shared parking facilities may effectively reduce the total number of required parking spaces by up to a maximum of 25%, subject to the criteria set forth below. [5] Municipal parking spaces displaced by an MX-1 Development shall be replaced at a ratio of 1:1, and shall be provided as public parking spaces located within 1,000 feet of their original location. If physical constraints make conformance with this requirement impossible, then said public parking spaces shall be sited in a location that best serves the parking demands of the MX-1 District as determined by the Planning Board as part of its site plan review. [a] Hardship provision. When an applicant has demonstrated to the satisfaction of the Planning Board that site constraints or financial hardship directly related to the requirement to replace municipal parking spaces described herein is infeasible financially or otherwise, and this hardship has not been created by the applicant, the Planning Board may modify or waive adherence to the interior construction standard as part of its site plan review. (c) Location of required parking spaces. [1] The Planning Board may allow all or part of the required parking to be located: i) on site; ii) in a garage or lot within 1,000 feet "as you walk" of the dwelling units or other permitted uses for which the parking spaces are required, as measured from the primary entrance of the structure containing said use to the closest edge of the garage or lot; or iii) a combination of both i) and ii), the amount of parking spaces provided in each category to be determined by the Planning Board as part of its site plan review. [2] Where the Planning Board approves the location of such parking spaces on a lot different from the lot occupied by the structure or use served, the Planning Board shall require a legal instrument, in form and filing, satisfactory to the Corporation Counsel assuring the continued use of said parking spaces in connection with the uses or structures served. (d) Applicants may propose less than the total required number of parking spaces for all uses if the spaces are provided as part of a shared use-parking facility. Shared use of required parking spaces may occur where two or more uses on the same site or on separate sites are able to share the same parking spaces because their parking demands occur at different times. A request for shared use of required parking spaces shall be submitted in writing to the Planning Board as part of its site plan review: [1] The names and addresses of the uses and of the owners or tenants who are sharing the parking; [2] The location and number of parking spaces that are being shared; [3] An analysis, prepared by a qualified planning or engineering professional, showing that the peak parking demands for the different uses occur at different times, and that the parking area will supply at least the minimum number of required spaces for each use during its respective peak parking times; [4] A legal instrument, such as but not limited to an easement or deed restriction, that guarantees access to the shared parking for all uses; and [5] Provisions that, in the event of a proposed change in use(s), such change may not take place unless there is sufficient parking to meet the standards for parking for each use or an application shall be submitted to the Planning Board in order to obtain approval for shared parking for the new use(s). (e) Applicants may propose to utilize attendant parking or automated parking facility in order to meet the off-street parking provisions where space for parking is limited. In any case where a reduction of the required area per parking space is permitted on the basis of the applicant's certification that such spaces will be fully attended, it shall be set forth in the certificate of occupancy that paid attendants employed by the owners or operators of such spaces shall be available to handle the parking and moving of automobiles at all times when such spaces are in use. (f) Private parking spaces constructed under the MX-1 District may be open to the public, with the restriction that all tenants of the structures for which the parking is constructed be given first right of refusal. (g) In certain cases, where applicants have difficulties supplying all required off-street parking on-site and have not been able to arrange alternative off-street parking within 1,000 feet of the primary entrance of the structure, applicants may, upon approval by the Planning Board, pay into a fee-in-lieu fund for the parking spaces not provided. In no instance shall the fee in lieu cover more than 10% of the required off-street parking for any structure. (8) Site design standards. Structure(s) within the MX-1 Commercial Corridor District shall be in accordance with the standards below, as determined by the Planning Board during site plan review and by the Architectural Review Board during certificate of appropriateness review. (a) Corner building wraps. [1] Structures located on corner lots should be designed with multiple front facades to create a continuous pedestrian-friendly and attractive public realm. [2] While one side of the building may support the primary entrance, both sides of the building on a corner lot must be functionally activated. [3] Service areas and building mechanical equipment should not be located along either building frontage on a corner lot. [4] At the intersection of two collector streets or the intersection of a collector street and local street, the Planning Board, as a part of its site plan review, may allow an increase in total height to ensure the visual prominence of said corner, while also ensuring that any development project is visually compatible with surrounding structures and the district at large. [image] (b) Use of green building techniques. [1] After construction, the development shall be eligible to receive US Green Building Council's LEED Gold Certification, LEED Silver Certification and/or Enterprise Green or a similar level of standards. Documentation on certification eligibility shall be provided to the Building Department and Planning Board for review. The Planning Board may modify the eligible LEED certification level if the applicant is able to demonstrate that the particularities of the development warrant modification due to site constraints or financial hardships that are directly related to the development of the project. [2] An applicant pursuing a similar standard shall demonstrate that the green building best practices being incorporated into the project are of similar or greater efficiency in water and energy usage or conservation and produce a carbon footprint that is similar or smaller than the LEED certification. (c) Buffers. [1] Any application to construct or alter a structure in the MX-1 Commercial Corridor District shall include provisions for a buffer screening area along any lot line abutting a lot in a residence district. Where such buffer screening is required, it shall be of a design, materials, location, type, height, spacing and arrangement to the satisfaction of the Planning Board. These requirements may be waived by the Planning Board in situations where the Planning Board determines that adjoining land uses, abutting street(s), topographic features or existing vegetation satisfy the same purpose. The plan and specifications for such buffer screening shall be filed with the plans for the use of the lot. [2] Any application consisting of a through lot shall include provisions for a buffer screening area where the lot abuts the street with the lesser road function class. Where such buffer screening is required, it shall be of a design, materials, location, type, height, spacing and arrangement to the satisfaction of the Planning Board. These requirements may be waived by the Planning Board in situations where the Planning Board determines that adjoining land uses, abutting street(s), topographic features or existing vegetation satisfy the same purpose. The plan and specifications for such buffer screening shall be filed with the plans for the use of the lot. (d) Site lighting. [1] Building windows and doors are not only simply utilitarian elements. Effective exterior site lighting is an important element in the overall appearance and operation of a project. [2] The quality of light, level of light as measured in footcandles, and the type of bulb or source should be carefully addressed. Lighting levels should not be so intense as to draw attention to the glow or glare of the project site. The lighting plan should incorporate current energy-efficient fixtures such as LED and similar technologies. [3] Spotlighting or glare from any site lighting should be shielded from adjacent properties and directed at a specific object or target area to prevent light trespass. Exposed bulbs should not be used. [4] Building light fixtures should be designed or selected to be architecturally compatible with the main structure. The height of light poles should be appropriately scaled to the project. [5] Artificial lighting of the grounds shall provide illumination sufficient for the convenience and safety of all residents and passersby. However, such outdoor lighting shall not project light onto, nor shall light sources be visible from, adjacent properties. No outdoor light source shall be more than 10 feet above the street level underneath it. [image] | [image] | [image] (e) Landscaping. [1] Building windows and doors are not only simply utilitarian elements. Landscaping enhances the visual image of the City, preserves natural features, improves property values, and alleviates the impact of noise, traffic, and visual distraction associated with certain uses. It aids in energy conservation and promotes urban wildlife habitats. [2] Trees and shrubs should be located and spaced to allow for long-term growth. Evergreen and deciduous or flowering trees should be used in combination to create visual interest and to create a dynamic landscape. Accent planting should be used around entries and key activity hubs. [3] Screening should be used to protect less intensive uses from the impacts of more intrusive uses and to block views of less desirable features from public view (trash enclosures, etc.). [4] The use of native plants is preferred. Xeriscaping is encouraged to promote water conservation, reduce maintenance requirements, and decrease flooding. Recycled grey water should be used for irrigation. [5] Landscaping should be coordinated with stormwater management plans, and features such as rain gardens and planted infiltration basins should be considered. [6] Use of drought-tolerant and native plantings. All plants to planted, installed and/or located within this MX-1 Zoning District shall be drought tolerant, hardy, native and appropriate for this area based on USDA plant hardiness zone. [7] Street trees. Street trees shall be hardy native species, tolerant to compaction, salt and air pollution to maximize the tree's chance of survival. The City of Mount Vernon Code lists approved species for planting which include but are not limited to the red oak, the pin oak and the scarlet oak. [image] (f) Vehicle ingress and egress. [1] Corner lots. On lots having frontages on intersecting streets, vehicular ingress and egress shall be from the street with the lesser road function class to accommodate building services and parking. [2] Through lots. On lots having frontages on more than one street, vehicular ingress and egress shall be on the street with the greater road function class to accommodate building services and parking. (g) Sidewalks and curbs. Sidewalks and curbs shall be designed and maintained in a state of good repair per Chapter 227 of the City of Mount Vernon Code. Curb and sidewalks shall be replaced by the applicant as necessary. A curb and adjacent sidewalk shall not be constructed monolithically, except a depressed curb for a driveway may be poured monolithically with the driveway. (h) Bicycle and pedestrian infrastructure. The Planning Board shall require, in its discretion, whether new bicycle and pedestrian infrastructure [in addition to that described in Subsection A(8)(g) herein] is appropriate for any development project. [1] Infrastructure criteria. Criteria for the Planning Board to consider when determining if bicycle and pedestrian infrastructure is required include, but is not limited to, the following: [a] Street classification and design. [b] Speed limits. [c] Surrounding terrain. [d] Bicycle and automobile traffic volumes. [e] Pedestrian counts. [f] On-street parking. [g] Street trees. [h] Building setbacks. [i] Expected number of users within a development. [j] Existing infrastructure. (i) Inflow and infiltration (I&I) reductions at a 3-to-1 ratio are required for all projects. The Department of Public Works shall provide direction to the Planning Board on how to address this requirement on a case-by-case basis. (9) Architectural design requirements. Structure(s) within the MX-1 Commercial Corridor District shall be in accordance with the requirements below, as determined by the Planning Board during site plan review and by the Architectural Review Board during certificate of appropriateness review. (a) Ground floor facades. In the context of a pedestrian-friendly district where streetscape and pedestrian activity is emphasized, the design and activation of the ground floor base is imperative. The concept of "build-to-lines" assures that new buildings will front on the public streetscape. Creating visual interest along the base of the building, by assuring a high percentage of transparency in storefront (or other nonresidential) windows is a design goal. Facade details are encouraged to vary the building texture, highlight facade articulation and break up the building mass. The provision of security grates, air-conditioning units or other similar fixtures on the principal facade must be avoided. [image] (b) Architectural detail. Architectural details are those elements that do not contribute structurally to a building's construction, but add visual interest, identify building styles, create building prominence and often display superior craftsmanship. All new structures or structures with significant facade renovation, defined as replacement or renovation of 50% or more of the facade, in the MX-1 District shall include architectural details on the structures' facade where visible by the public. Architectural details shall include, but are not limited to, ornate or detailed brickwork, window details, pediments, cornices, ornate lighting, hand rails and fencing, downspouts and paving materials. [image] (c) Functional entries. To improve the pedestrian experience and to facilitate the activation of the public realm surrounding individual buildings, pedestrian access points (functional entries) should be easily identifiable, inviting and accessible and located along the public frontage as often as practical. Maximizing the number of functional entries also helps to create interesting and diverse street-level architecture. Accessways into the buildings may be into lobbies, commercial spaces or common areas. All functional entries should meet ADA requirements, and be adequately lit. [image] (d) Building materials. Each new structure shall be considered a long-term addition to the neighborhood; the exterior design and building materials shall exhibit permanence and design excellence that shall continue to be architecturally relevant. The design employed and the materials used shall complement the surrounding architecture and contribute to the overall development of the neighborhood character. [image] (e) Building transition. Attention during the structures' design phase shall assure appropriate bulk and height of structures adjacent to lower-density residential neighborhoods. The massing of taller structures shall be organized in such a way that the apparent bulk and height of new structures is minimized at the MX-1 District's edge. [image] (f) Interior construction standard. To foster flexibility in the division of ground floor commercial space, interior commercial space shall be constructed and/or designed to allow the space to be temporarily subdivided without affecting structural integrity in the event the internal ground floor commercial space must be subdivided or recombined for greater marketability purposes. For development projects containing more than 12,000 square feet of ground floor commercial space, a minimum of 25% of the ground floor retail/commercial space shall be set aside for small-scale and/or local commercial tenants. [1] Hardship provision. When an applicant has demonstrated to the satisfaction of the Planning Board that site constraints or financial hardship directly related to the interior construction standard described herein makes compliance to the interior construction standard infeasible financially or otherwise, and this hardship has not been created by the applicant, the Planning Board may modify or waive adherence to the interior construction standard as part of its site plan review. (g) Signage. The provision of high-quality signage, both as a communication tool and as a component of building form, is a goal in the MX-1 District. Creative and unique sign designs are encouraged while cluttered and unattractive streetscapes must be prevented. In general, effectively designed signs should respond to the site, landscape, and architectural design context within which they are located. Signs should be compatible in scale, proportion, and design with the building's facade and its surroundings. Painted window signs should not be too large or obscure transparency. Internally illuminated "sign boxes" should be avoided, as should excessive lighting of all varieties. Projecting signs, perpendicular to the sidewalk, are effective when properly scaled for pedestrian use. Graphics should be well-designed and legible. The use of neon can be acceptable, when employed properly. The signage requirements established in Article XIII shall apply. [image] (h) Canopies and awnings. Awnings over pedestrian walkways and sidewalks are encouraged to provide shade and rain protection while adding interest to a facade with shape and color. They are also effective in identifying a business. Long expanses of awnings are discouraged. Awnings should have a pedestrian scale and be placed so as to provide weather protection and/or business identification to potential patrons of a business. Awnings should be an enhancement to the building facade and should not obscure ornamental features of a building and should be proportional with and complementary to nearby buildings and awnings. Awnings are preferred to be a solid color. If stripes are used, subtle or muted colors are preferred. Striped awnings with highly contrasting, bright colors may be construed as visually blaring and inappropriate. [image] (10) Supplemental standards. (a) In effort to preserve the tax base, jobs and/or industry located within the "Washington Street Light Industrial Area," the following additional standards shall apply within the MX-1 Zoning District: [1] Mixed-use structures are not permitted to face and/or front Haven Avenue except where a collector street intersects a local road within the MX-1 District. In instances where a collector street intersects a local road and the property contains lot width and frontage along Haven Avenue, the property(ies) shall be considered a Tier 2 in accordance with chapter. [2] In order for a mixed-use structure to be constructed and/or permitted within a property that contains frontage on Haven Avenue, the Haven Avenue tax lot(s) shall be merged with a tax lot(s) that contains lot width and frontage along East Third Street. The merged tax lots shall be subject to the same mortgages, liens or encumbrances as result of the tax merger. Otherwise the I zone regulations shall apply. [3] Property which contains frontage along Haven Avenue where a mixed-use structure(s) is permitted shall have building services and parking located along Haven Avenue within the MX-1 Zoning District. The primary entrance to the mixed-use structure(s) shall be located along East Third Street. [4] The following properties within the MX-1 zoning district containing lot width and frontage along Haven Avenue shall meet the MX-1 zoning district additional regulations for mixed-use structure(s) to be constructed: [a] Section 165.73, Block 4006, Lot 22; [b] Section 165.73, Block 4006, Lot 23; [c] Section 165.73, Block 4006, Lot 24; [d] Section 165.73, Block 4006, Lot 25. (b) Merging tax lots. A property owner who owns two or more contiguous parcels of land that are subject to the same mortgages, liens or encumbrances within the MX-1 Commercial Corridor District shall merge all directly or indirectly associated tax lots for municipal regulation and tax purposes through the office of the City Tax Assessor. (c) Utilities shall be installed underground, and any aboveground equipment shall be located away from pedestrian streets and corners. Equipment boxes and vaults should be placed in back of the sidewalk and where landscaping can minimize or screen their impact. Relocation and provisions for private and public underground utility systems shall be made, as needed. These requirements may be waived by the Planning Board in situations where it determines that the underground installation of utilities is not appropriate and/or that adjoining land uses, topographic features or existing vegetation satisfy the same purpose in terms of minimizing or screening equipment boxes and/or vaults. The costs of relocating the underground utility lines shall, where appropriate, be borne by the utility companies and/or private developers, pursuant to the appropriate laws, regulations and ordinances. (d) Historic commemoration. Applicants are required to commemorate any/all historically, culturally, architecturally and/or archaeologically significant site(s), as identified by the Department of Planning and Community Development staff. This commemoration shall include a minimum of at least but not limited to one of the following: a monument; memorial; marker; plaque; mural; and/or other method acceptable to the Planning Board. Such commemoration shall be approved by the Planning Board during site plan approval. The Planning Board shall consider the following when rendering its decision: [1] Location of commemoration; [2] Ownership of commemoration; [3] Appropriateness of commemoration; [4] Maintenance of commemoration; [5] Durability of materials; [6] Scale of commemoration; and [7] Level of design/craftsmanship incorporated. (e) Usable open space and/or recreation areas. [1] Except as provided below, each Tier 1 and Tier 2 mixed-use development shall set aside 10% of the total lot area as usable open space and/or recreation areas. All usable open space/recreation areas shall be legally and practicably accessible to the occupants of the development from which the required open space/recreation area is taken, but need not be exclusively for the use of the occupants of the development. The Planning Board shall have the right to require that the applicant or owner execute such agreements and covenants as it may deem to be required to ensure the usable open space/recreation area remains as such for perpetuity. All usable open space and/or recreation areas shall be at least 20 feet wide. [2] Where the Planning Board determines that a suitable open space/recreation area cannot be properly located on the property, or is otherwise not practical, the Board shall require, as a condition of site plan approval, a payment to the City of a fee in lieu of open space/recreation area which shall be placed in a dedicated fund to be used by the City exclusively for creating or maintaining open space/recreation areas. (f) Compatibility with generic environmental impact statement. Applicants must demonstrate that the expected impacts of their project are consistent with, and will not exceed, the impacts of the MX-1 District on both the rezoning study area and the broader land use study area as identified in the generic environmental impact statement that was prepared for the MX-1 District. Pursuant to 6 NYCRR 617.13, the applicable lead agency may include a chargeback to recover a proportion of said agency's actual costs expended for the preparation of the generic environmental impact statement. (g) Market rate. For each development project located within the MX-1 District containing residential units, no less than 50% of said residential units shall be set aside for market-rate housing. (h) An applicant proposing a community purpose building or space must show, by dollar and cents evidence, that such a proposed use will be economically viable. (11) Review process. (a) The procedure for site plan approval by the Planning Board shall follow Article VII of this chapter. In addition to requirements under Chapter 267, Article VII, § 267-38, the application shall include: [1] Proposed location of any public community and/or recreation facilities. [2] A description of any alternative means of parking to be utilized. [3] Any proposed amenities in accordance with the density bonus section[2] identified previously within this chapter. (b) The procedure for certificate of appropriateness approval by the Architectural Review Board shall follow Chapter 10 of the City Code and shall include: [1] Proposed location of any public community and/or recreation facilities. [2] Any proposed amenities in accordance with the density bonus section[3] identified previously within this chapter. (12) Conflicts with other zoning requirements. If any provision of the MX-1 Commercial Corridor District conflicts with any other requirement of this chapter, the MX-1 Commercial Corridor District provision shall supersede the other requirement to the extent of such inconsistency. B. Mount Vernon West TOD. (1) General provisions. (a) Overview. The Mount Vernon West Transit Oriented Development Zone (designated as MVW) has been established to implement the vision for the area realized during the development of the Mount Vernon Comprehensive Plan, and through the efforts of the Technical Committee for Mount Vernon West and the Vision Plan process facilitated by the Pace University Law School, Land Use Law Center. (b) Applicability. The Mount Vernon West Transit Oriented Development Zone applies to property designated as MVW on the City of Mount Vernon Zoning Map, which is on file in the Office of the City Clerk. Parcels located in the zone are more specifically known and designated as: TOD — Hub | TOD - Corridor | TOD - Transition 164.68-1056-12 | 164.60-1074-33 | 164.68-1072-1 164.68-1056-11 | 164.60-1074-32 | 164.68-1072-27 164.68-1056-10 | 164.60-1074-31 | 164.68-1072-26 164.67-1057-16 | 164.60-1074-30 | 164.68-1072-25 164.67-1057-13 | 164.60-1074-29 | 164.68-1072-24 164.75-1057-1 | 164.60-1074-35 | 164.68-1072-23 164.75-1057-2 | 164.60-1074-28 | 164.68-1072-22 164.75-1057-3 | 164.60-1074-27 | 164.68-1072-21 164.75-1057-4 | 164.60-1074-26 | 164.68-1072-20 164.75-1057-12 | 164.60-1074-25 | 164.68-1072-19 164.75-1057-14 | 164.60-1074-24 | 164.68-1072-18 164.75-1057-5 | 164.68-1074-23 | 164.68-1072-17 164.75-1057-6 | 164.68-1074-21 | 164.68-1072-29 164.75-1057-7 | 164.68-1074-22 | 164.68-1072-16 164.75-1057-11 | 164.68-1074-20 | 164.68-1072-30 164.68-1056-18 | 164.68-1074-19 | 164.68-1072-2 164.68-1056-1 | 164.68-1074-18 | 164.68-1072-3 164.68-1056-2 | 164.68-1074-17 | 164.68-1072-4 164.68-1056-4 | 164.76-1061-1 | 164.68-1072-5 164.68-1056-5 | 164.76-1061-23 | 164.68-1072-6 164.68-1056-6 | 164.76-1061-24 | 164.68-1072-7 164.68-1056-7 | 164.76-1061-25 | 164.68-1072-8 164.68-1056-8 | 164.76-1061-26 | 164.68-1072-9 164.68-1056-9 | 164.76-1062-1 | 164.68-1072-10 164.68-1058-10 | 164.76-1071-12 | 164.68-1072-11 164.68-1058-1 | 164.76-1071-11 | 164.68-1072-12 164.68-1058-2.1 | 164.76-1071-10 | 164.76-1064-39 164.68-1058-2.2 | 164.76-1071-9 | 164.76-1064-38 164.68-1058-3 | 164.76-1071-8 | 164.76-1064-37 164.75-1058-5 | 164.76-1071-20 | 164.76-1064-36 164.75-1058-6 | 164.76-1065-1 | 164.76-1064-35 164.75-1058-7 | 164.76-1065-37 | 164.76-1064-34 164.75-1058-9 | 164.76-1065-2 | 164.76-1064-33 164.68-1073-1 | 164.76-1065-3 | 164.76-1064-32 164.68-1073-2 | 164.76-1065-4 | 164.76-1064-31 164.68-1073-3 | 164.76-1065-5 | 164.76-1064-30 164.68-1073-4 | 164.76-1065-6 | 164.76-1064-29 164.68-1073-28 | 164.76-1065-7 | 164.76-1064-28 164.68-1073-27 | 164.76-1065-8 | 164.76-1064-27 164.68-1073-26 | 164.76-1070-21 | 164.76-1064-26 164.68-1073-25 | 164.76-1070-19 | 164.76-1064-25 164.68-1073-24 | 164.76-1070-18 | 164.76-1064-24 164.68-1073-23 | 164.76-1066-1 | 164.76-1064-23 164.68-1073-22 | 164.76-1066-2 | 164.76-1064-22 164.68-1073-21 | 164.76-1066-3 | 164.76-1064-21 164.68-1073-20 | 164.76-1066-4 | 164.76-1064-20 164.68-1073-29 | 164.76-1066-5 | 164.76-1064-19 164.68-1073-34 | 164.76-1066-6 | 164.76-1064-17 164.68-1073-5 | 164.76-1066-7 | 164.76-1064-3 164.68-1073-6 | 164.76-1069-15 | 164.76-1064-4 164.68-1073-7 | 164.76-1069-14 | 164.76-1064-5 164.68-1073-8 | 164.76-1069-13 | 164.76-1064-6 164.68-1073-9 | 164.76-1069-11 | 164.76-1064-7 164.68-1073-10 | 164.76-1069-10 | 164.76-1064-8 164.68-1073-11 | 165.69-1069-8 | 164.76-1064-9 164.68-1073-12 | 165.69-1069-7 | 164.76-1064-10 164.68-1073-13 | 165.69-1067-1 | 164.76-1064-11 164.68-1073-14 | 165.69-1067-3 | 164.76-1064-12 164.68-1073-15 | 164.76-1067-4 | 164.76-1064-13 164.68-1073-16 | 164.76-1067-5 | 164.76-1064-14 164.68-1073-17 | 164.76-1067-6 | 164.76-1064-15 164.68-1073-18 | 164.69-1068-1 | 164.76-1064-16 164.68-1073-19 | 165.69-1068-2 | 164.76-1064-44 164.68-1072-15 | 165.69-1068-3 | 164.68-1071-1 164.68-1072-28 | 165.69-1068-4 | 164.68-1071-17 164.68-1072-14 | 165.69-1068-5 | 164.68-1071-16 164.68-1072-13 | 165.69-1068-6 | 164.68-1071-15 164.76-1064-1 | | 164.68-1071-14 164.76-1064-2 | | 164.68-1071-13 164.68-1063-1 | | 164.76-1065-36 164.76-1063-26 | | 164.76-1065-35 164.76-1063-25 | | 164.76-1065-34 164.76-1063-24 | | 164.76-1065-33 164.76-1063-23 | | 164.76-1065-32 164.76-1063-22 | | 164.76-1065-31 164.76-1063-15 | | 164.76-1065-30 164.76-1063-18 | | 164.76-1065-29 164.68-1063-2 | | 164.76-1065-28 164.68-1063-3 | | 164.76-1065-27 164.68-1063-4 | | 164.76-1065-26 164.68-1063-29 164.68-1063-5 164.76-1063-6 164.76-1063-7 164.76-1063-30 164.76-1063-8 164.76-1063-9 164.76-1063-10 164.76-1063-11 164.76-1063-31 164.76-1063-12 164.76-1063-13 164.76-1063-14 164.76-1063-16 164.76-1063-17 164.75-1060-29 164.75-1060-1 164.75-1060-2 164.75-1060-3 164.75-1060-6 (c) Purpose and intent. The MVW Zoning District provides for a diverse array of uses (industrial, commercial and residential) in a compatible manner, oriented around the Mount Vernon West train station. Specifically, the MVW Zone provides for: [1] Higher density residential development in close proximity to the Mount Vernon West train station and other modes of public transit. [2] The physical integration and coordination of diverse land uses. [3] Development that is maximally transit supportive. [4] The creation of a pedestrian-friendly environment. [5] The provision of an alternative to traditional development that emphasizes mixed-uses. [6] Reduction of auto dependency and roadway congestion by locating multiple destinations and trip ends within walking distance of one another. [7] Reduce total vehicle miles traveled and regional greenhouse gas emissions. [8] Repair, stabilize and revitalize the areas urban fabric. [9] Facilitate new development and redevelopment that will create new jobs. [10] Position the area as a concentrated investment area. [11] Strengthen the Mount Vernon gateway to Mount Vernon from Yonkers. [12] Emphasize, support and facilitate high quality building design, streetscape and public realm improvements. (d) Organization. [1] The MVW zone utilizes the concept of a form-based code to set guidelines for development. A form-based code creates a predictable public realm by establishing guidelines and regulations that focus primarily on the physical form of the environment, with a lesser focus on specific land-use requirements. [2] Form-based codes address the relationships between building facades and the public realm, the form and mass of buildings in relation to one another, and the scale and types of streets and blocks. The guidelines and standards in this form-based code are presented in the narrative language of the code, but also graphically, to describe the character of anticipated development. This is in contrast to conventional zoning's focus on the management and segregation of land uses. [3] Subsection B(2) presents the regulating plan, which defines development areas within the MVW boundaries, Subsection B(3) identifies the eight allowable building types in the MVW district and Subsection B(4) indicates where the building types are and are not permitted. Subsection B(5) identifies the standards for building design, configuration and placement. Subsection B(6) presents the table of permitted uses. Subsection B(7) identifies the parking requirements for the MVW district. Subsection B(8) presents design guidelines, in which all projects are expected to comply. Finally, Subsection B(9) sets forth the administrative procedures in which all projects in the MVW District must comply. (e) Relationship to comprehensive plan. [1] The long range planning vision and strategy of the City of Mount Vernon has identified the Mount Vernon West area as a "Higher Intensity Planning Area." This designation signifies a district where higher development density is targeted and encouraged. Through the efforts of the Technical Committee for Mount Vernon West, a vision plan was developed that provided the foundation upon which the Mount Vernon West Transit Oriented Development Zoning Ordinance is constructed. [2] The Mount Vernon West Transit Oriented Development Zoning Ordinance is therefore fully consistent with long range planning vision and strategy for the Mount Vernon West area, and represents the implementation of that vision. (f) Planning principles. The Mount Vernon West Transit Oriented Development Zoning Ordinance establishes an efficient, effective and equitable regulatory and procedural code for the use of land in the Mount Vernon West area, subject to the following policies: [1] The area should include a framework of transit, pedestrian and bicycle systems that provide alternatives to the automobile. [2] Development in the area should be compact, pedestrian oriented and contain a mix of uses. [3] The development of isolated, single-use buildings and sites should be avoided. [4] The ordinary activities of daily living should be provided within walking distance of residential uses, allowing for independence from the automobile. [5] The layout and configuration of development should be designed to disperse traffic and reduce the length of automobile trips. [6] Within the area, a range of housing types and price levels should be provided to accommodate diverse ages and incomes. [7] Appropriate land uses and densities should be provided within walking distance to the train station. [8] Civic, institutional and commercial activity should be embedded throughout the area, and not isolated into remote single-use complexes. [9] A range of open space, including parks, squares, plazas, and playgrounds, should be distributed throughout the area. [10] Buildings, landscaping and other amenities should contribute to the physical definition of thoroughfares as public places. [11] Development should adequately accommodate automobiles while respecting pedestrians and the spatial form of public areas. [12] The design of buildings and sites should reinforce safe environments, but not at the expense of accessibility. [13] Architecture and landscape design should reflect the history and traditions, topography, climate and building practices of the City of Mount Vernon. [14] Public gathering places should be provided as locations that reinforce community identity and support self-government. [15] The preservation and renewal of historic buildings, or the incorporation of historical architectural elements characteristic of the City of Mount Vernon, should be facilitated, to affirm the continuity and evolution of society. (g) Nonconforming uses and buildings. [1] The MVW District replaces zoning that was predominantly industrial. While many of the industrial uses have left the area, and a number of properties in the area are underutilized, viable industrial uses do remain in places. [2] The MVW zoning provides for the addition of a broad array of uses, including high-density residential uses. Facilitating the coexistence of diverse land uses represents one of the challenges in the MVW District. [3] The regulations governing nonconforming uses set forth in § 267-10 remain applicable to uses and buildings in the MVW District. However, all legal preexisting, nonconforming uses are encouraged to comply with the design guidelines established herein, to assure that the area evolves in a manner that is consistent with the goals and objectives of the City. (2) Regulating plan. The regulating plan divides the MVW Zone into five separate areas of development intensity. This approach differs from conventional zoning that typically divides a city into zones that rigidly segregate residential, commercial, industrial and institutional uses, thereby emphasizing a dependence on automobiles to functionally connect uses. The use of zones based on development intensity (instead of land uses) provides a new spatial basis for regulating development that recognizes the interrelationships between uses. The three zones also provide an effective vehicle to implement the City's urban design objectives while fostering attractive and sympathetic interfaces between zones. The following zones are established within the MVW District: MVW-H | MVW Hub MVW-H(NC) | MVW Hub - Noncommercial MVW-C | MVW Corridor MVW-T | MVW Transition MVW-T(NC) | MVW Transition - Noncommercial (a) MVW Hub (MVW-H). The MVW Hub Zone is designed to accommodate the highest intensity of development within the MVW District. Development in this zone shall require building entrances to be located within 1,500 feet of the Mount Vernon West train station, and shall rely on the public transit opportunities available at the station, to minimize reliance on individual passenger vehicles, parking demands and associated traffic impacts. The MVW-H zone also allows for the greatest diversity of land uses. As a result, building design and architectural quality is a priority. Integrating diverse land uses requires careful attention to the interface between buildings and uses, pedestrian connections, the provision of parking, building services and the operational requirements of various uses. (b) MVW Hub - Noncommercial [MVW-H(NC)]. The MVW Hub - Noncommercial Zone is located along north side of North Terrace Avenue, between Mount Vernon Avenue and Grove Street. It includes all of the attributes of the MVW-H Zone, except commercial uses are prohibited. This allows for an appropriate juxtaposition between the existing residential uses on the east side of North Terrace Avenue with potential new development in the MVW-H Zone. (c) MVW Corridor (MVW-C). The MVW Corridor Zone provides the physical link between the MVW Hub and the downtown. This corridor provides the gateway into the Mount Vernon from Yonkers and anchors the western edge of the downtown at West Lincoln Avenue. The emphasis in this area is on retail, retail service and restaurant uses along the ground floor of the buildings lining the corridor, to create an economically vibrant and bustling commercial and mixed-use area that will unite the MVW Hub with the downtown. (d) MVW Transition (MVW-T). The MVW Transition zone lies to the east of the MVW Hub and flanks the MVW Corridor zones. This area offers the potential for residential redevelopment at increased densities. Redevelopment will likely require the assembly of parcels. The MVW-T zone will provide for a logical and gradual transition from the higher densities of development permitted in the MVW Hub, and the existing lower density development situated to the east. (e) MVW Transition - Noncommercial [MVW-T(NC)]. The MVW Transition - Noncommercial Zone is located on the west side of North Terrace Avenue, between Mount Vernon Avenue and Oak Street. It includes all of the attributes of the MVW-T Zone, but it extends into the MVW-H area to create a broader noncommercial buffer between new development in the MVW-H and the existing residences located to the east. [image] (3) Allowable building types. This section establishes and defines the building types permitted in the MVW Zoning District to ensure that proposed development is consistent with the goals for building form, physical character, land use and aesthetic quality. [image] Mixed-Use BuildingA building that supports ground floor commercial use, with upper story residential or office uses. | [image] One-Story CommercialA one-story, large format building that accommodates a variety of commercial uses | [image] General CommercialA building type that accommodates retail, office or other commercial uses. [image] Civic BuildingA building that accommodates civic, institutional or public uses | [image] Multifamily ApartmentThree or more dwelling units vertically and horizontally integrated | [image] Tower on PodiumMulti-story apartment building constructed atop a podium containing off-street parking wrapped by ground level commercial uses [image] TownhouseThree or more dwelling units where each unit is separated vertically by a party wall | [image] Detached DwellingSingle or two-family dwelling units on an individual lot with yards on all sides (4) Permitted building types by district. Building types are allowed by district, as set forth below: Permitted Building Types by District Building Type | MVW-H | MVW-H(NC) | MVW-C | MVW-T | MVW-T(NC) [image] Mixed-use building | P | N | P | N | N [image] One-story commercial | N | N | P | N | N [image] General commercial | P | N | P | N | N [image] Civic building | P | N | P | N | N [image] Multifamily apartment | N | P | N | P | P [image] Tower on podium | P | P | N | N | P [image] Townhouse | N | N | N | P | P [image] Detached dwelling | N | N | N | P | P (5) Building type regulations. (a) Mixed-use building. [1] Lot. [image] Lot Dimensions A — Lot area (minimum) | 5,000 square feet B — Lot width (minimum) | 50 feet Usable Open Space D — Usable open space | 200 square feet per dwelling unit [2] Building placement. [image] Building Setbacks A — Common lot line | 0 feet or 10 feet (if provided) B — Lot line abutting RMF-10/15 | 30 feet Build-To Line C — Building along primary street | 70% Buildings in TOD-C(minimum percentage of lot width) | 100% D — Building along side street(minimum percentage of lot depth) | 35% Parking Setbacks E — Primary street | 30 feet F — Side street | 10 feet G — Parking location | Behind building Coverage H — Building (maximum) | 60% I — Impervious surface (maximum) | 75% [3] Height and mass. [image] Building Height A — Building height | 5 stories/60 feet Story Height B — Ground story height floor to ceiling (minimum) | 13 feet C — Upper story height floor to ceiling (minimum) | 9 feet Building Mass D — Max length of upper story street-facing wall without offset | 75 feet E — Upper story street-facing wall offset depth (minimum) | 4 feet F — Upper story street-facing wall offset length (minimum) | 8 feet G — Building length, street-facing facade (maximum) | 175 feet [4] Activation. [image] Transparency A — Ground story, primary street facade (minimum) | 60% B — Ground story, side street facade (minimum) | 40% C — Blank wall length, primary street (maximum) | 30 feet D — Blank wall length, side street (maximum) | 40 feet Functional Entries E — Functional entries (minimum) | 70 feet F — Area of garage or service bay openings along street-wall (maximum) | 20% Permitted Building Elements Porch | No Stoop | No Balcony | Yes Awning/canopy | Yes Forecourt | Yes (b) General commercial. [1] Lot. [image] Lot Dimensions A — Lot area (minimum) | 5,000 square feet B — Lot width (minimum) | 50 feet [2] Building placement. [image] Building Setbacks A — Common lot line | 0 feet or 10 feet (if provided) B — Lot line abutting RMF-10/15 | 30 feet Build-To Line C — Building along primary street | 70% Buildings in TOD-C(minimum percentage of lot width) | 100% D — Building along side street(minimum percentage of lot depth) | 35% Parking Setbacks E — Primary street | 30 feet F — Side street | 10 feet G — Parking location | Behind building Coverage H — Building (maximum) | 60% I — Impervious surface (maximum) | 80% [3] Height and mass. [image] Building Height A — Building height | 4 stories/50 feet Story Height B — Ground story height floor to ceiling (minimum) | 10 feet C — Upper story height floor to ceiling (minimum) | 9 feet Building Mass D — Max length of upper story street-facing wall without offset | 75 feet E — Upper story street-facing wall offset depth (minimum) | 4 feet F — Upper story street-facing wall offset length (minimum) | 8 feet G — Building length, street-facing facade (maximum) | 175 feet [4] Activation. [image] Transparency A — Ground story, primary street facade (minimum) | 60% B — Ground story, side street facade (minimum) | 20% C — Blank wall length, primary street (maximum) | 35 feet D — Blank wall length, side street (maximum) | 40 feet Functional Entries E — Functional entries (minimum) | 80 feet F — Area of garage or service bay openings along street-wall (maximum) | 20% Permitted Building Elements Porch | No Stoop | No Balcony | Yes Gallery | No Awning/canopy | Yes Forecourt | Yes (c) One-story commercial. [1] Lot. [image] Lot Dimensions A — Lot area (minimum) | 5,000 square feet B — Lot width (minimum) | 50 feet [2] Building placement. [image] Building Setbacks A — Common lot line | 0 feet or 10 feet (if provided) B — Lot line abutting RMF-10/15 | 20 feet Build To Line C — Building along primary street | 70% Buildings in TOD-C(minimum percentage of lot width) | 100% D — Building along side street(minimum percentage of lot depth) | 35% Parking Setbacks E — Primary street | 30 feet F — Side street | 10 feet G — Parking location | Behind building Coverage H — Building (maximum) | 75% I — Impervious surface (maximum) | 90% [3] Height and mass. [image] Building Height A — Building height | 1 story/25 feet Story Height B — Ground story height floor to ceiling (minimum) | 13 feet Building Mass C — Max length of street-facing wall without offset | 65 feet D — Street-facing wall offset depth (minimum) | 4 feet F — Street-facing wall offset length (minimum) | 8 feet G — Building length, street-facing facade (maximum) | 175 feet [4] Activation. [image] Transparency A — Primary street facade (minimum) | 60% B — Side street facade (minimum) | 20% C — Blank wall length, primary street (maximum) | 30 feet D — Blank wall length, side street (maximum) | 40 feet Functional Entries E — Functional entries (minimum) | 70 feet F — Area of garage or service bay openings along street-wall (maximum) | 20% Permitted Building Elements Porch | No Stoop | No Balcony | No Gallery | Yes Awning/canopy | Yes Forecourt | Yes (d) Tower on podium. [1] Lot. [image] Lot Dimensions A — Lot area (minimum) | 15,000 square feet B — Lot width (minimum) | 100 feet Usable Open Space D — Usable open space | 130 square feet per dwelling unit [2] Building placement. [image] Building Setbacks A — Common lot line | 0 feet or 10 feet (if provided) B — Lot line abutting RMF-10/15 | 20 feet Build-To Line C — Podium along primary street(minimum percentage of lot width) | 70% D — Podium along side street(minimum percentage of lot depth) | 35% Parking Setbacks E — Primary street | 30 feet F — Side street | 10 feet G — Surface parking location | Behind building H — Parking garage | Same as podium Coverage H — Principal building (maximum) | 85% I — Impervious surface (maximum)(provided open space is provided on podium) | 100% [3] Height and mass. [image] Building Height A — Building height (plus podium) | 15 stories/150 feet(1) Story Height B — Ground story height floor to ceiling (minimum) | 11 feet C — Upper story height floor to ceiling (minimum) | 7 feet 6 inches Building Mass D — Max length of ground floor street-facing wall without offset | 75 feet E — Ground floor street-facing wall offset depth (minimum) | 5 feet F — Ground floor street-facing wall offset width | 10 feet G — Max length of upper floor street-facing wall without offset | 45 feet or J H — Upper story street-facing wall offset depth (minimum) | 4 feet I — Upper story street facing wall offset width (minimum) | 8 feet J — If G is not met, provide an architectural element that changes the facade plane, a minimum of 10 feet in width. Parking Garage Storefront Wrap K — Ground floor primary street | Required NOTES: (1) | Maximum building height may be extended to 20 stories per density bonus provision of § 267-21. [4] Activation. [image] Transparency A — Ground story, primary street facade (minimum length) | 60% B — Ground story, side street facade (minimum) | 20% E — Podium blank wall length, primary street (maximum) | 30 feet F — Podium blank wall length, side street (maximum) | 40 feet Functional Entries G — Functional entries (minimum) | 90 feet H — Area of garage or service bay openings along street-wall (maximum) | 20% Permitted Building Elements Porch | Yes Stoop | Yes Balcony | Yes Gallery | Yes Awning/canopy | Yes Forecourt | Yes (e) Civic building. [1] Lot. [image] Lot Dimensions A — Lot area (minimum) | 5,000 square feet B — Lot width (minimum) | 50 feet [2] Building placement. [image] Building Setbacks A — Front yard | 25 feet B — Common lot line | 0 feet or 10 feet (if provided) C — Lot line abutting RMF-10/15 | 30 feet Build-To Line D — Building along primary street | 50% Buildings in TOD-C(minimum percentage of lot width) | 100% E — Building along side street(minimum percentage of lot depth) | 30% Parking Setbacks F — Primary street | 10 feet G — Side street | 10 feet H — Parking location | Behind building Coverage I — Building (maximum) | 60% J — Impervious surface (maximum) | 80% [3] Height and mass. [image] Building Height A — Building height | 3 stories/40 feet [4] Activation. [image] Transparency A — Ground story, primary street facade (minimum) | 60% B — Ground story, side street facade (minimum) | 40% C — Blank wall length, primary street (maximum) | 30 feet D — Blank wall length, side street (maximum) | 40 feet Functional Entries E — Functional entries (minimum) | 70 feet F — Area of garage or service bay openings along street-wall (maximum) | 20% Permitted Building Elements Porch | Yes Stoop | Yes Balcony | Yes Gallery | Yes Awning/canopy | Yes Forecourt | Yes (f) Multifamily apartment. [1] Lot. [image] Lot Dimensions A — Lot area (minimum) | 7,500 square feet B — Lot width (minimum) | 75 feet Usable Open Space D — Usable open space | 200 square feet per dwelling unit [2] Building placement. [image] Building Setbacks A — Front yard | 20 feet B — Common lot line | 0 feet or 10 feet (if provided) C — Lot line abutting RMF-10/15 | 30 feet Build-To Line D — Building along primary street (minimum percentage of lot width) | 70% E — Building along side street (minimum percentage of lot depth) | 35% Parking Setbacks F — Primary street | 30 feet G — Side street | 10 feet H — Surface parking location | Behind building I — Parking garage | Same as principal building Coverage J — Building (maximum) | 60% K — Impervious surface (maximum) | 70% [3] Height and mass. [image] Building Height A — Building height | 6 stories/70 feet Story Height B — Ground story height floor to ceiling (minimum) | 10 feet C — Upper story height floor to ceiling (minimum) | 9 feet Building Mass D — Max length of upper story street-facing wall without offset | 75 feet E — Upper story street-facing wall offset depth (minimum) | 4 feet F — Upper story street-facing wall offset length (minimum) | 8 feet G — Building length, street-facing facade (maximum) | 175 feet [4] Activation. [image] Transparency A — Ground story, primary street facade (minimum) | 20% B — Ground story, side street facade (minimum) | 20% C — Upper story, primary street facade (minimum) | 35% D — Upper story, side street facade (minimum) | 45% E — Blank wall length, primary street (maximum) | 40 feet F — Blank wall length, side street (maximum) | 50 feet Functional Entries G — Functional entries (minimum) | 100 feet H — Area of garage or service bay openings along street-wall (maximum) | 20% Permitted Building Elements Porch | Yes Stoop | Yes Balcony | Yes Gallery | No Awning/canopy | Yes Forecourt | Yes (g) Townhouse. [1] Lot. [image] Lot Dimensions A — Lot area (minimum) | 40,000 square feet B — Lot width (minimum) | 150 feet Usable Open Space D — Usable open space | 200 square feet per dwelling unit [2] Building placement. [image] Building Setbacks A — Front yard | 25 feet B — Side yard | 15 feet C — Rear yard | 30 feet D — Spacing between buildings | 1/2 height of end wall Build-To Line E — Building along primary street (minimum percentage of lot width) | 70% Parking Setbacks F — Parking location | Behind building and garages. Coverage G — Building (maximum) | 40% H — Impervious surface (maximum) | 60% [3] Height and mass. [image] Building Height A — Principal building height | 3 stories/40 feet B — Accessory building height | 1 story/15 feet Story Height C — Ground story height floor to ceiling (minimum) | 9 feet D — Upper story height floor to ceiling (minimum) | 9 feet Unit Size E — Width (minimum) | 30 feet [4] Activation. [image] Transparency A — Ground story, primary street facade (minimum) | 20% B — Blank wall length, primary street (maximum) | 35 feet Functional Entries C — Functional entries | On primary street Permitted Building Elements Porch | Yes Stoop | Yes Balcony | Yes Gallery | No Awning/canopy | No Forecourt | No (h) Detached dwelling. [1] Lot. [image] Lot Dimensions A — Lot area (minimum) | 4,500 square feet B — Lot width (minimum) | 50 feet Usable Open Space D — Usable open space | 500 square feet per dwelling unit [2] Building placement. [image] Building Setbacks A — Front yard | 25 feet B — Side yard (one) | 2 feet C — Side yard (both) | 5 feet D — Rear yard | 20 feet Parking Setbacks E — Parking location | Driveway or garage Coverage F — Building (maximum) | 40% G — Impervious surface (maximum) | 70% [3] Height and mass. [image] Building Height A — Principal building height | 3 stories/35 feet B — Accessory building height | 1 story/15 feet [4] Activation. [image] Functional Entries A — Functional entries | On primary street Permitted Building Elements Porch | Yes Stoop | Yes Balcony | Yes Gallery | No Awning/canopy | No Forecourt | No (6) Permitted use table. MVW Zone Permitted Uses P = PermittedSP = Special PermitX = Prohibited Residential Uses Use | MVW-H | MVW-H(NC) | MVW-C | MVW-T | MVW-T(NC) One-family dwelling | X | X | P | P | P Attached dwelling and two-family dwellings | X | X | P | P | P Multifamily dwellings | P | P | P | P | P Public/Civic Uses Public schools | P | P | P | P | P Community purpose building | P | P | P | P | P Municipal uses for Mount Vernon | P | P | P | P | P Places of worship | SP | SP | SP | SP | SP Public utility | SP | SP | SP | SP | SP Use of government agencies | P | P | P | P | P Parking garage | P | P | P | P | P Commercial Uses Day-care center | P | P | P | SP | SP Nursery school | P | P | P | SP | SP Domiciliary care facility | P | P | P | SP | SP University, college and private school | SP | SP | SP | SP | SP Off-street parking facility | SP | SP | SP | SP | X Business, professional offices | P | X | P | X | X Retail | P | X | P | X | X Personal services | P | X | P | X | X Museums and art galleries | P | X | P | X | X Medical and dental offices | P | X | P | X | X Medical laboratories | P | X | P | X | X Business and trade schools | P | X | P | X | X Retail laundries and dry cleaners | P | X | P | X | X Hotels and motels | P | X | P | X | X Motor vehicle dealerships | SP | X | P | X | X Bars, nightclubs, catering halls | SP | X | SP | X | X Bakeries, retail | P | X | P | X | X Restaurants | P | X | P | X | X Restaurants, carry-out | P | X | P | X | X Restaurants, fast food | P | X | P | X | X Funeral parlor | X | X | SP | X | X Banks | P | X | P | X | X Motor vehicle service stations | X | X | SP | X | X Motor vehicle rental agencies | X | X | SP | X | X Social clubs | SP | X | SP | X | X Storage of commercial vehicles | SP | X | SP | X | X Theater and concert halls | P | X | P | X | X Animal hospital | P | X | P | X | X Wholesale business | SP | X | X | X | X Industrial | SP | X | X | X | X Wireless telecommunications facility | SP | SP | SP | SP | SP Accessory Uses Incidental customary accessory uses | P | P | P | P | P (7) MVW Hub density bonus. (a) For property located in the MVW - Hub area, bounded by the MetroNorth railroad to the west, West Street to the east and Oak Street to the north, as depicted on the following map, a density bonus may be applied. [image] (b) The City Council may, at its discretion and subject to the standards and considerations set forth below, grant a density bonus of up to a maximum of five stories (for a maximum height of 20 stories) for buildings located in that portion of the MVW — Hub area described above. A density bonus may be granted in exchange for an applicant providing one or more of the following off-site civic improvements, amenities or development actions above and beyond those that are directly or indirectly necessitated by the proposed project itself. [1] Provision, renovation or rehabilitation of a public open space amenity. By contributing a significant provision, renovation donation and/or or rehabilitation of a public open space amenity, to include but not limited to a public park and/or other public open space, a density bonus may be granted. The usable open space required for a development, as set forth in the building type regulations shall not count towards this amenity. [2] Historic preservation. Preserving a significant portion of a building(s) or structure(s) identified by the Commissioner of Planning and Community Development and agreed to by the Planning Board as having historical, cultural and/or architectural significance. [3] Brownfield or derelict property remediation. Applicants may apply for a density bonus for providing brownfield or derelict property (as defined in the City Code) remediation on lots other than those currently before the City for development within the MVW District, to prepare the property(ies) for either dedication for public use for redevelopment by a public or private owner. The Building Department shall provide a list of preferred properties for rehabilitation. [4] Contribution to non-site-related infrastructure improvements. Non-site-related improvements are considered significant improvements that are not directly needed, required or related to the subject site development, but may indirectly improve the area. Infrastructure improvements may include, but are not limited to significant provisions, renovations, creation, donation, installation and/or rehabilitation of public solid waste and recycling receptacles, traffic calming measures, public seating, wider than required sidewalks, specialty pavers or utility covers as part of district "branding," repaving of a street(s), intersection upgrades (including streetlights and crosswalks), bus shelters, and storm or sanitary sewer improvements. The City Department of Public Works may provide recommendations to the Planning Board. [5] Provision of creating alternative off-site parking facilities. By contributing to the creation of an off-site parking facility, above and beyond the off-street parking requirements for the proposed development included in this district, which may include, but is not limited to creation the of a public off-street parking garage, dedicating land for the creation of a public off-street parking facility or the creation of a privately operated parking facility, a density bonus may be granted, that would provide additional parking proportionate to the size and scope of the project. [6] Provision of public artwork. Incorporation of publicly accessible artwork including but not limited to sculpture(s), monument(s), or other permanent aesthetic structure(s) on a site or at a designated off-site location as deemed appropriate by the Planning Board. [7] Provision of housing for persons with disabilities. For developments with public financing the provision of housing for persons with disabilities must go above and beyond the requirements set forth in the applicable public financing source, setting aside a minimum of 10% of units for persons with physical disabilities with 2% for persons with sight or hearing disabilities inclusive. Developments with no public financing shall make its best effort to meet the United States Housing and Urban Development § 504 minimum requirements for accessibility or demonstrate to the satisfaction of the Planning Board the inability to do so. (c) In granting the density bonus for the amenities listed above, the City Council shall consider the following criteria: [1] The incentives being proposed and the degree to which the proposed amenity is compatible with the goals and objectives for the MVW Zoning District, and the City's long range planning strategy. [2] Set forth in the public record, in detail, the amenities to be provided by the applicant, how those amenities further the purposes of the MVW Zoning District and the City's long range planning strategies, how they preserve and enhance the aesthetic, environmental and/or historical qualities and features of this district for the benefit and enjoyment of the entire community and otherwise promote the public health, safety and welfare of the community. [3] The associated maintenance schedule and ownership of the proposed amenity(ies). [4] The density bonus can be successfully integrated into the overall building/site design without negatively impacting, detracting and/or severely departing from an appropriate height, scale, mass, size, and shape of the proposed structure(s). [5] The density bonus can be successfully integrated into the overall building/site design without negatively impacting, detracting and/or severely departing from an appropriate height, scale, mass and/or size of the surrounding area. [6] Set forth in the public record, in detail, the relationship between the amenities being provided and the bonus being awarded and shall specify the rationale supporting the proportionality of the amenities to the bonus. The public benefit improvements provided shall be roughly proportional in nature and extent to the bonus granted, and their proportionality shall be demonstrated by the applicant and agreed to by the City Council. The City Council shall make its determination concerning the density bonus after receipt and consideration of a written recommendation from the Architectural Review Board and any other department or consultants the City Council deems appropriate given the additional improvements proposed in seeking a density bonus. Within 30 days of the City Council's written request, the Architectural Review Board and any other department or consultant whose input is requested by the City Council, shall provide their comments as to the advisability and appropriateness of architecture and/or aesthetics of the requested density bonus and the proposed civic improvement(s), amenity(ies) or development action(s). The recommendation of the Architecture Review Board and any other department or consultant whose input is requested by the City Council, shall assist the City Council in determining the whether the density bonus is warranted in that instance and the proportionality of the civic improvements to that of the density bonus requested. The cost of the improvements need not equal the value of the benefits granted. The granting or denial of any density bonus shall be solely within the discretion of the City Council using the criteria set forth in this section. [7] In the event an application for a zoning variance is made to the Zoning Board of Appeals to increase the number of stories in excess of the 15 stories permitted via the density bonus, the Zoning Board of Appeals should, in balancing the equities, consider whether it is practical for the applicant to provide any of the listed amenities in order to obtain a density bonus in lieu of a variance. (8) Parking regulations. The MVW District is designed as a "park once" area, wherein people driving to the district are encouraged to park in one location, and then travel by foot within the area to various other destinations, rather than driving from one location to another. Design emphasis and priority is given to pedestrian circulation. As a result, the required parking in the MVW District reflects reduced off-street parking ratios for certain uses. The use of shared parking is also permitted and encouraged. The off-street parking requirements established in the Table of Off-Street Parking and Loading Requirements, set forth in Chapter 267, Attachment 3, shall apply, unless modified below, in which case the requirements of this section shall apply. (a) Off-street parking requirements. Use | Required Parking Residential Uses Attached one-family dwelling units | 1.75 per dwelling unit Multifamily dwellings in TOD-H | 0.7 per dwelling unit containing no more than 2 bedrooms. 0.9 per dwelling unit containing more than 2 bedrooms Multifamily dwellings in TOD-C | 1.0 per dwelling unit containing no more than 2 bedrooms. 1.25 per dwelling unit containing more than 2 bedrooms Multifamily dwellings in TOD-T | 1.5 per dwelling unit containing no more than 2 bedrooms. 2.0 per dwelling unit containing more than 2 bedrooms Nonresidential Uses Business, professional or governmental offices | 1 per 650 square feet GFA Retail stores, shops and personal service establishments | 1 per 450 square feet GFA Restaurants | 1 per 5 seats or 1 per 300 square feet of GFA, whichever is greater (b) Shared parking. The concept of shared parking, whereby land uses that have different parking demand patterns are able to use the same parking spaces throughout the day, is particularly useful in a transit oriented development district, where a large percentage of trips are accommodated via public transit. Public transit reduces the overall demand for individual passenger vehicle trips and the related demand for parking. Shared parking is permitted and encouraged in the MVW district. The City Council, if the application is subject to review by the City Council or Planning Board, in all other instances, may consider the use of shared parking, according to the following provisions: [1] The uses proposing to share parking spaces are different land uses as set forth in the Permitted Use Table. [2] All new development that relies on shared parking must demonstrate the adequacy of the proposed parking as a result of a capacity being provided that will substantially meet the intent of the parking requirements by reason of variation in the probable time of maximum use by residents, patrons, visitors or employees among residences and establishments sharing such parking, and provided that said approval of such joint use shall be automatically terminated upon the termination of the operation of any use on which the shared parking analysis has been based. The analysis of shared parking must be based on established standards/methodology. [3] In cases where shared parking is proposed between adjacent parcels under separate ownership, irrevocable cross-easements shall be required, to assure the perpetual right to share the parking spaces. [4] No more than 50% of the required parking for a particular use shall be provided in a shared parking arrangement. (c) Design and layout. The design and layout of off-street parking spaces shall comply with the provisions of § 267-38, except as modified herein: [1] To minimize curb cuts on the roadways in the MVW district, the use of shared driveways are encouraged, where feasible. [2] No curb cuts shall be permitted on lots in the TOD-C Zone fronting on Mount Vernon Avenue, Grove Street or Oak Street. [3] Where feasible, driveways shall front on streets that are less pedestrian intensive. [4] Off-street parking is encouraged to be as inconspicuous as possible and to incorporate landscaping and screening to the greatest extent possible to minimize its physical and visual impact. [5] Off-street parking and loading areas shall be coordinated with the public street system serving the MVW district in order to avoid conflicts with through-traffic, obstruction to pedestrian walks and vehicular thoroughfares. [6] All parking structures shall be designed using compatible or complementary materials to the principal buildings so that they blend in architecturally. All voids in the structures shall be architecturally treated or screened, so that lights and vehicles are not individually visible. [7] Parking structures fronting on MacQuesten Avenue and Mount Vernon Avenue shall be wrapped by first floor nonresidential uses. [8] Surface parking shall include streetlighting that adequately provides for safe vehicle circulation and public safety, but shall not be excessive. Light poles shall be as low as possible to achieve the desired purpose, and fixtures shall be shielded and downward directed. The use of energy efficient luminaries is encouraged. [9] All pedestrian pathways across and along parking areas shall be appropriately lit with pedestrian scaled lighting fixtures. [10] Vehicular access to internal parking structures shall be designed so as not to negatively impact upon major pedestrian routes. If necessary, provide "fish eye" mirrors or alarms to manage the interaction between pedestrians and vehicles. [11] The potential conflicts between truck delivery, vehicular traffic, and pedestrian circulation shall be considered when designing service entries, roadways, walkways, and pedestrian entrances. [12] To the extent possible, service entrances and loading areas between adjacent buildings shall be consolidated. Such service entrances shall be separated from walkways and pedestrian entrances. [13] In each parking lot containing over 150 parking spaces, at least two of the parking spaces must be provided with an electric vehicle charging station. [14] Spaces for handicapped car and van parking must be provided as required by law. [15] Within a structured parking garage, up to 30% of the total parking spaces provided may be compact spaces. No more than six compact parking spaces may abut each other. Compact spaces may be reduced to 7.5 feet in width. All compact parking spaces must be clearly and visibly striped and labeled for compact car use only. [16] All surface parking lots with frontage on a street, shall be screened as follows: [a] A minimum ten-foot-wide landscaped area with a continuous row of shrubs must be provided between the street and the parking lot. [b] Shrubs must be a minimum of 18 inches in height when planted and must reach a minimum size of 36 inches in height within three years of planting. [c] Plantings adjacent to driveways shall be designed so as to prevent sight distance impediments, and therefore may be lower in height then specified above. [d] A thirty-six-inch wall within a minimum five-foot planting strip may be substituted for a continuous row of shrubs. The design and physical appearance of the wall shall be subject to the approval of the City. [e] Breaks for pedestrian and vehicle access are allowed. [17] To minimize the extent of impervious surfaces and the "heat-island" effect, and to enhance the aesthetic appearance of surface parking lots, the following landscaping requirements shall apply: [image] [a] Interior islands: [i] A landscaped interior island shall be provided every 10 parking spaces. Interior islands shall be distributed evenly throughout the parking area. [ii] An interior or terminal island shall be a minimum of 8.5 feet in width and 300 square feet in area. [iii] All rows of parking must terminate with a landscaped terminal island. No more than 30 parking spaces may located between drive aisles. [iv] Interior islands may be consolidated or intervals may be expanded in order to preserve existing trees. [v] Interior islands must be installed below the level of the parking lot surface to allow for runoff capture. [b] Median islands: [i] A landscape median island shall be provided between every six single parking rows. [ii] A landscape median island shall be a minimum of five feet wide. [iii] A median island may also serve as the location for a sidewalk. In such case, the sidewalk shall be a minimum of six feet wide, and the remaining planting area shall be no less than five feet wide. [iv] Median islands may be consolidated or intervals may be expanded in order to preserve existing trees. [v] Median islands must be installed below the level of the parking lot surface to allow for runoff capture. [c] Tree coverage: [i] Each interior island (and terminal interior island) must include at least one shade tree. [ii] In no case can there be less than one tree for every 3,000 square feet of parking area. [18] Off-street parking areas shall be surfaced with asphalt bituminous, concrete or other type of dustless material in accordance with the City of Mount Vernon standards and specifications and maintained in a smooth, well-graded condition. [19] Pervious or semi-pervious parking area surfacing materials may be provided in accordance with the City of Mount Vernon standards and specifications. Permitted materials may include but are not limited to "grasscrete," ring and grid systems used in porous or grid pavers, or recycled materials such as glass, rubber, used asphalt, brick, block and concrete. Once installed, all pervious or semi-pervious parking areas shall be maintained in accordance with the manufactures specifications. (9) [image] [image] [image] Design guidelines. This section of the MVW form based code describes recommended design practices that have been established to create a high-quality, pedestrian friendly urban environment oriented around the Mount Vernon West train station. The principles described in this section are not considered mandatory development standards. However, all projects are strongly encouraged to utilize this section to design projects that meet the purpose and intent of these guidelines. The ultimate approval of projects will be judged in accordance with these design practices. (a) Ground floor facades. [1] In the context of a transit oriented district where pedestrian activity is emphasized, the design and activation of the ground floor base is imperative. [2] The concept of "build-to-lines" assures that new buildings will front on the public streetscape. Creating visual interest along the base of the building, by assuring a high percentage of transparency in storefront windows is a design goal. Facade details are encouraged to vary the building texture, highlight facade articulation and break-up the building mass. [3] [image] [image] [image] The provision of security grates, air conditioning units or other similar fixtures on the principal facade must be avoided. (b) Architectural details. [1] Building architecture creates an interesting visual environment and provides a basis for the overall character of an area. [2] Architectural details are those elements that do not contribute structurally to a building's construction, but add visual interest, identify building styles, and often display superior craftsmanship. They should not be used however, as a substitute for genuine building massing and articulation. [3] [image] [image] [image] New construction should emphasize the use and application of a high degree of architectural detailing. Building renovations should strive to preserve unique or native vernacular details. (c) Corner building wraps. [1] Structures located on corner lots should be designed with multiple front facades to create a continuous pedestrian friendly and attractive public realm. [2] While one side of the building may support the primary entrance, both sides of the building on a corner lot must be functionally activated. [3] Service areas and building mechanical equipment should not be located along either building frontage on a corner lot. (d) Functional entries. [1] To improve the pedestrian experience and to facilitate the activation of the public realm surrounding individual buildings, pedestrian access points (functional entries) should be easily identifiable, inviting and accessible and located along the public frontage as often as practical. Maximizing the number of functional entries also helps to create interesting and diverse street level architecture. [image] | [image] | [image] [2] Accessways into the buildings may be into lobbies, commercial spaces or common areas. [3] All functional entries should meet ADA requirements, and be adequately lit. (e) [image] [image] [image] Building off-sets. [1] Building offsets serve to break-up large monotonous building facades and increase the amount of light and openness at the street level. [2] The MVW building type regulations establish specific building mass requirements, which include building offset provisions. These are established as minimum requirements. Further variations to facades are encouraged. [3] In instances when physical offsets are impractical, an architectural element that alters the buildings facade plane can be utilized. (f) Building transitions. [1] The transitional edge of the MVW District requires careful attention to assure appropriate bulk and height of structures adjacent to lower-density residential neighborhoods. [image] | [image] | [image] [2] The massing of taller structures should be organized in a way that minimizes the apparent bulk and height of new buildings. This can be accomplished in three ways - by careful selection of building types at the zone's edges, providing landscape buffers or setbacks and providing offsets in taller buildings. (g) Building materials. [1] [image] [image] [image] The choice of materials used for construction or renovating buildings affects the way a building relates to its neighborhood context. When designed well, a building can contribute to the continuity of street elevation, as well as emphasize a site's unique characteristics. Buildings constructed with complementary materials contribute to the interest of a streetscape. Consequently, a building's design, particularly the facade, and exterior materials can have a significant impact on how the structure is perceived. [2] Exterior walls shall be clad in materials that are durable and are appropriate to the visual environment and climate. Design flexibility and creativity is encouraged using ornamentation that is consistent with the overall character of the City of Mount Vernon. The use of materials such as stone, brick and wood is preferred. (h) Windows and doors. [1] [image] [image] Building windows and doors are not only simply utilitarian elements, but also provide ornament, adding materially to the regularity and elegance of the building. [2] The dimensions and style of windows and doors and patterns of fenestration should have a relationship to the surrounding neighborhood to create a visual rhythm along the street and a sense of continuity among structures. (i) Signs. [1] The provision of high quality signage, both as a communication tool and as a component of building form is a goal in the MVW District. Creative and unique sign designs are encouraged while cluttered and unattractive streetscapes must be prevented. [2] In general, effectively designed signs should respond to the site, landscape, and architectural design context within which they are located. Signs should be compatible in scale, proportion, and design with the building's facade and its surroundings. Painted window signs should not be too large or obscure transparency. Internally illuminated "sign boxes" should be avoided, as should excessive lighting of all varieties. Projecting signs, perpendicular to the sidewalk are effective when properly scaled for pedestrian use. Graphics should be well-designed and legible. The use of neon can be acceptable, when employed properly. [3] The signage requirements established in Article XIII shall apply. [image] | [image] | [image] [image] | [image] | [image] (j) Site lighting. [1] [image] Effective exterior site lighting is an important element in the overall appearance and operation of a project. [2] The quality of light, level of light as measured in footcandles, and the type of bulb or source should be carefully addressed. Lighting levels should not be so intense as to draw attention to the glow or glare of the project site. The lighting plan should incorporate current energy-efficient fixtures such as LED and similar technologies. [3] Spotlighting or glare from any site lighting should be shielded from adjacent properties and directed at a specific object or target area to prevent light trespass. Exposed bulbs should not be used. [4] Building light fixtures should be designed or selected to be architecturally compatible with the main structure. The height of light poles should be appropriately scaled to the project. (k) Building services. [1] [image] [image] [image] To create a more attractive pedestrian friendly environment, utilitarian features, such as trash facilities, loading docks, HVAC equipment and aboveground utility infrastructure, should be out of the public's view. Ground level services should be located at the rear of the building, if possible. A screen wall should be used to camouflage the service features if optimal placement does not adequately screen the features from the public realm. Landscape treatments may be appropriate to soften the interface of the equipment. [2] The location, design and visibility of vehicular drive-through facilities should respect the pedestrian environment, the desired urban density and the aesthetics of the facility. Drive-through entrance and exit lanes should not be located on the primary pedestrian thoroughfares of MacQuesten Parkway or Mount Vernon Avenue. Drive-through bays, stacking areas and queues should be screened from the public realm. (l) Project open spaces. [1] [image] [image] [image] Residential developments and mixed-use projects require the provision of usable open space for residents. These amenities increase light and air to dwelling units, enhance the aesthetics of projects and the environmental quality of neighborhoods, promote physical activity, afford stormwater management opportunities, increase social interaction opportunities with neighbors and increase safety by providing "eyes on the space." [2] Usable open space can be provided in outdoor spaces such as courtyards, walkways, rooftops, balconies and terraces and garden plots. Indoor facilities such as fitness centers or swimming pools can also be used to meet the usable open space requirements of a project. [3] Unique features such as green roofs and green or "living" walls are also beneficial open space amenities. (m) Streetscape. [1] Great streetscapes are the center of public life. They brand a neighborhood, giving it a cultural identity and shaping the perceptions of the area. The elements of the streetscape can create a place of vitality and activity. [2] [image] [image] [image] The streetscape is composed of three zones: the pedestrian zone, public amenity zone and frontage zone. [3] Sidewalks, a minimum of 15 feet wide are required throughout the district. Curb cuts should be minimized and clearly marked. Street trees with grates should be provided at thirty-foot intervals. Planters are encouraged containing seasonal plantings and flowers. Wayfinding signage should be provided to assist pedestrian navigation through the area. Banners and flags can be used to announce special events and to help brand the district, as can public art. Street and pedestrian lighting should illuminate at a level consistent with pedestrian activity. Benches, seating and other street furniture should be selectively sited to take advantage of sunshine in winter and shade in summer. The provision of bus stops is an essential component to the MVW District, as are bicycle racks that should be located at regular intervals. (n) Traffic calming. [1] [image] [image] [image] The safety of pedestrians and cyclists in a transit oriented district is imperative. Traffic calming is an effective method to minimize conflicts between motorists and pedestrians. [2] Traffic calming involves changes in street alignment, installation of barriers, and other physical measures to reduce traffic speeds and/or cut-through volumes, in the interest of street safety, livability, and other public purposes. [3] Traffic calming measures include speed humps, speed tables, raised crosswalks, raised intersections, textured pavement, traffic circles, roundabouts, chicanes, neck-downs, chokers among other measures. (o) Pedestrian and bicycle circulation. [1] In order to facilitate pedestrian movement throughout the district, sidewalks a minimum of 15 feet wide are required. [2] [image] [image] [image] Pedestrian crosswalks across streets should have pedestrian controls (walk/don't walk signals) and improved with a different pavement treatment to differentiate it from the street paving. Corner clearances should be minimized (neck-downs) so that the distance a pedestrian must cross the road is reduced. Larger surface parking lots should provide separate pedestrian connects through the parking lot. [3] Bicycle circulation should be accommodated via the provision of defined bike lanes (four feet in width) and signed bike routes. Short-term bike parking (bike racks) in retail areas and long-term bike parking (lockers, covered corrals, etc) at commutation points and businesses, are necessary. Businesses should provide on-site shower and changing facilities for employees. (p) Landscaping. [1] Landscaping enhances the visual image of the City, preserves natural features, improves property values, and alleviates the impact of noise, traffic, and visual distraction associated with certain uses. It aids in energy conservation and promotes urban wildlife habitats. [2] [image] [image] [image] Trees and shrubs should be located and spaced to allow for long-term growth. Evergreen and deciduous or flowering trees should be used in combination to create visual interest and to create a dynamic landscape. Accent planting should be used around entries and key activity hubs. [3] Screening should be used to protect less intensive uses from the impacts of more intrusive uses and to block views of less desirable features from public view (trash enclosures, etc.). [4] The use of native plants is preferred. Xeriscaping is encouraged to promote water conservation, reduce maintenance requirements, and decrease flooding. Recycled grey water should be used for irrigation. [5] Landscaping should be coordinated with stormwater management plans, and features such as rain gardens and planted infiltration basins should be considered. (q) Sustainability and green building. [1] [image] [image] [image] Sustainability and green building refers to the practice of creating structures using a process that is environmentally responsible and resource-efficient throughout a building's life-cycle: from siting to design, construction, operation, maintenance, renovation, and demolition. [2] Elements include the construction of buildings that are energy efficient (high levels of insulation, high-performance windows) and that use renewable resources (passive solar heating, daylighting), are designed for durability, future reuse and adaptability, use low maintenance building materials with low embodied energy. Building materials should be locally sourced, with a high percentage of salvaged and recycled materials. Install high efficiency heating and cooling equipment, high efficient lights and appliances and water efficient equipment. (r) Bird-friendly building design. [1] Bird collisions with tall buildings have been identified as a significant issue, particularly during the spring and fall migrations. Reducing bird mortality can be accomplished by employing bird-friendly building techniques. [2] [image] [image] [image] Three basic design techniques exist to minimize bird collisions: [a] Minimize the use of glass. [b] Place glass behind screening. [c] Use glass with properties that reduce collisions. [3] Design techniques include the use of netting, screens, grilles shutters and exterior shades; employing awnings and overhangs; using angled glass; using patterned glass; using UV patterned glass; using opaque or translucent glass; using window films; applying decals or tape or installing interior shades or blinds. Reference should be made to the New York City Audubon Society publication "Bird Friendly Building Design." (10) Administration. The transit oriented, pedestrian friendly zoning standards and requirements set forth herein are designed to provide specific guidance for the development of property and street enhancements within the MVW District while allowing for flexibility and creativity in project design in order to foster the appropriate growth of the area in an orderly and desirable fashion. (a) Project review and approval. [1] Three approval tracks are available in the MVW District: [a] No review. [i] Under this track, if a project is classified as a Type II Action pursuant to the State Environmental Quality Review Act ("SEQRA"), site plan approval from the Planning Board or the issuance of a certificate of appropriateness from the Architectural Review Board is not required. While formal approval is not required, the Architectural Review Board shall be provided the opportunity to review and comment on the application. Upon the acceptance of a complete application by the Department of Planning and Community Development, the application shall be referred to the Architectural Review Board. Within 35 days of its receipt, the Architectural Review Board shall forward their review comments back to the Department of Planning and Community Development. [ii] In order to effectuate the no review track, the City must adopt the Type II list contained in Part 617.5 of the SEQRA Regulations and must also add to this list the following: [A] Any single use permitted in the MVW District that is proposed for a single existing lot, with frontage on and direct access to a street improved to City standards, access to all utilities, is below all Type I thresholds, is not adjacent to any critical environmental area or parkland, is not within 500 feet of any municipal boundary and meets all bulk, design and other requirements of the MVW District and the zone within which the proposed development is located, without any waiver or exception ("MVW Type II"). [iii] The City Council may adopt or periodically amend its own Type II list, following a public hearing. The list must then be filed with the Commissioner of the New York State Department of Environmental Conservation, who will maintain the list to serve as a resource for agencies and interested persons. The Commissioner will provide notice in the environmental notice bulletin of such procedures upon filing. The City's Type II list may not be less protective of the environment than the statewide Type II list established in Section 617.5 of the SEQRA regulations. Any activities added to the City's Type II list shall only apply in the City of Mount Vernon, and do not apply to any agencies in other jurisdictions. [b] Expedited review. [i] Under this review track, an Expedited Review Committee consisting of the Commissioner of Planning and Community Development, Commissioner of Buildings and Commissioner of Public Works shall review an eligible application and shall within 30 days of the receipt of a complete application, provide a recommendation of approval or denial to the City Council and Architectural Review Board. If the Committee recommends approval, the application then goes to the City Council and Architectural Review Board, which shall grant approval, approval with modifications or denial within 35 days, or 65 days in the event the Applicant is also seeking a density bonus, unless more time is needed due to scheduling conflicts or in order to comply with other provisions of state or local law, in which case the City Council and Architectural Review Board shall act as soon as practicable, without the need for a public hearing. [ii] This track is for projects larger than those described in Subsection B(10)(a)[1][a] above that also fully comply with the provisions of the MVW Zone. [iii] In order for a project to be eligible for expedited review, the following conditions shall be met: [A] The development must be wholly located within the MVW-H, MVW-H(NC), MVW-C, MVW-T, MVW-T(NC) zones. [B] No waivers or variances are required. [C] The applicant must document that the project complies with all findings of the SEQRA generic environmental impact statement adopted for the MVW rezoning, and will not result in any impacts that exceed the thresholds established therein. [D] The proposed action is classified as either a Type II (other than an MVW Type II) or unlisted action pursuant to SEQRA, 6 NYCRR, Part 617. Type I Actions are not eligible for expedited review. [E] The project does not exceed 249 dwelling units or 99,000 square feet of nonresidential gross floor area. [c] Full review. [i] The full review track would be required for all projects that are not eligible for expedited review or no review, have received a recommendation of a denial by the Expedited Review Committee. [ii] Projects following the full review track shall comply with the requirements of Chapter 267 Article VII, Site Plan Approval, and Chapter 10 of the City Charter. [2] In all instances, applications for full review approval in the MVW District, shall follow the following process: [a] Pre-application conference. [i] Prior to completion of project design and formal submittal of the required application, an applicant must schedule a pre-application conference with representatives of the City of Mount Vernon Department of Planning and Community Development, Building Department and Department of Public Works to discuss the procedures, standards and regulations. [ii] A request for a pre-application conference by a potential applicant must be accompanied by preliminary project plans and designs and the required filing fee. [iii] The representatives of the Department Planning and Community Development, Building Department and Department of Public Works will inform the applicant of the requirements as they apply to the proposed project, provide a preliminary list of issues that will likely be of concern during formal application review, suggest possible modifications to the project, and identify any technical studies that may be necessary for the review process when a formal application is submitted. [iv] The representatives of the Department of Planning and Community Development, Building Department and Department of Public Works shall determine which of the three project review tracks the project must follow, no review, expedited review or full review. [b] Application requirements. [i] All site plan applications shall be prepared in accordance with the requirements of § 267-33. [ii] In addition to the requirement to submit an environmental assessment form with the application (whether a short or full EAF is required shall be determined at the pre-application conference), the applicant shall also submit a report documenting whether the project complies with all Findings of the SEQRA Generic Environmental Impact Statement adopted for the MVW rezoning, and will not result in any impacts that exceed the thresholds established therein, or in the alternative, shall specifically identify areas where the project is inconsistent or nonconforming. [c] Completeness review. [i] All applications must be sufficient for processing before the Department of Planning and Community Development shall accept the application for review. [ii] Within 15 calendar days of the receipt of the application, the Department of Planning and Community Development must notify the applicant in writing whether or not the application is complete or whether additional information is required. [iii] An application for site plan approval and/or certificate of appropriateness shall be sufficient for processing when it contains all of the information necessary to decide whether or not the development as proposed will comply with all of the requirements of the Code. [iv] If the Department of Planning and Community Development determines that the application is not complete and additional information is required, then the applicant shall provide any and all additional information requested. [v] If the applicant does not submit the additional requested information in a form deemed to be satisfactory or otherwise complete the application within 45 days after the Department of Planning and Development has notified the applicant in writing that additional information is required, the application shall be deemed to be abandoned and the application fee and any other fee submitted shall be forfeited. [vi] This does not prevent any applicant from resubmitting an application if the same has been abandoned, so long as all of the above steps are completed. [d] Required public hearing. [i] A duly noticed public hearing shall be held for all applications processed under the full review track. [ii] The Expedited Review Committee may require that a public hearing be held for a site plan and/or certificate of appropriateness processed under the expedited review track, if community input is determined to be necessary to allow for a well-informed approval decision to be rendered. (b) Decisionmaking. In rendering a decision, the Expedited Review Committee, City Council and/or Architectural Review Board shall take into consideration the following criteria: [1] Compatibility with the City's long range goals and planning strategy; [2] The project does not adversely change the neighborhood character; [3] The project fosters mixed use development patterns within appropriate areas; [4] The project conceals density through building design where appropriate; [5] The project will encourage appropriate use of the land in accordance with general purposes, intent and spirit of this chapter and not detrimental to surrounding property values; [6] The safety, health, welfare or the order of the City shall not be adversely affected by the proposed use and its location; [7] The site is suitable for the location of such use in the City; [8] That the proposed project is consistent with all findings of the SEQRA generic environmental impact statement adopted for the MVW rezoning; [9] That there is sufficient roadway access to provide for emergency services while reducing transportation needs; [10] That proposed landscaping and buffer areas have natural and attractive plantings that are compatible with the adjacent area and terrain; [11] That the applicant exhibits the wherewithal to complete the project; [12] That the project provides for innovative and imaginative approaches to transit oriented development that does not detract from the existing neighborhood character; [13] That the proposed project has appropriate height, scale, mass, size, shape and density in relationship to its location, and consistent with the MVW zoning provisions; [14] The historical, architectural and/or cultural significance of the existing site or existing structures is assesses to address local significance; [15] That there is the consideration of the staff recommendation. (c) Supplemental standards. [1] Merging tax lots. A property owner who owns two or more contiguous parcels of land that are subject to the same mortgages, liens or encumbrances within the MVW Zoning District shall merge all directly or indirectly associated tax lots for municipal regulation and tax purposes through the Office of the City Tax Assessor. [2] Utility location. Utilities shall be installed underground and any above ground equipment shall be located away from pedestrian street corners. Equipment boxes and vaults should be placed in back of the sidewalk and where landscaping can minimize or screen their impact. Relocation of provisions for private and public underground utility systems shall be made, as needed. These requirements may be waived by the Planning Board in situations where it is determined that the underground installation of utilities is not appropriate and/or that adjoining land uses, topographic features or existing vegetation satisfy the same purpose in terms of minimizing or screening equipment boxes and/or vaults. The costs of relocating the underground utility lines shall, where appropriate, be borne by the utility companies and/or private developers, pursuant to the appropriate laws, regulations and ordinances. [3] Historic commemoration. Applicants are required to commemorate any/all historically, culturally, architecturally and/or archaeologically significant site(s), as identified by the Department of Planning and Community Development staff. This commemoration shall include at least, but not limited to one of the following: a monument; memorial, marker; plaque; mural and/or other method acceptable to the City. Such commemoration shall be approved by the Planning Board during site plan approval. The Planning Board shall consider the following items when rendering its decision regarding historic commemoration: [a] Location of commemoration; [b] Ownership of commemoration; [c] Appropriateness of commemoration; [d] Maintenance of commemoration; [e] Durability of materials; [f] Scale of commemoration; and [g] Level of design/craftsmanship incorporated. [4] Interior construction. To foster and encourage larger total commercial floor area along the ground floor of structure(s) within the MVW Zoning District, interior commercial space along the ground floor shall be constructed and/or designed to maximize the total amount of usable commercial ground floor area. Accordingly, structural supports and/or beams shall be located, placed, installed, constructed and/or designed to allow the flexibility of ground floor commercial spaces to be temporarily internally subdivided without affecting the structural integrity of the overall structure(s) in the event the internal ground floor commercial space must be recombined for greater marketability purposes. [5] Affordable housing unit location. In instances where a development includes affordable or workforce housing units, said units shall be fully integrated into and dispersed throughout the project so as to be indistinguishable from other market rate units. Affordable or workforce units shall not be isolated, clustered or grouped. Additionally, access to affordable and workforce housing units shall be provided in a manner similar to all other market rate units, and shall not be physically segregated. Affordable and workforce housing units shall be designed, constructed and finished in a manner similar to the other market rate units within the project.

[Added 4-30-2021 , approved 4-30-2021 ]

Ask a question about Mount Vernon law

Corpus searches the Mount Vernon sections it holds and shows the ones that match, with their citations. Free, no sign-in.