For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 23-732 — Floor area ratio and open space ratio in R6 through R9 Districts

New York City Administrative Code (current through L.L. 2026/147, enacted September 12, 2026, and amendments effective through October 10, 2026) · NYC Zoning Resolution § 23-732

Corpus is an independent public-information project, not the official City of New York website. Stable reference: corpuslaw.us/code/da6ec6ef-be55-41d8-8a1c-71cd71527a9a

23-732 - Floor area ratio and open space ratio in R6 through R9 Districts

R6 R7 R8 R9 In the districts indicated without a letter suffix, for sky exposure plane buildings, the minimum required open space ratio and the maximum floor area ratio for any zoning lot shall be determined by the height factor of such zoning lot as set forth in this Section. Where elected, such floor area ratio shall supersede the floor area ratio provisions of Section 23-22, and apply to all residences, including qualifying affordable housing or qualifying senior housing. The minimum open space required through the application of a minimum open space ratio shall be applied in conjunction with the applicable regulations of Section 23-30 (YARDS, COURTS AND OTHER OPEN AREA REGULATIONS). The obstructions set forth in Section 23-311 shall per permitted in required open space. MINIMUM REQUIRED OPEN SPACE RATIO AND MAXIMUM FLOOR AREA RATIO R6 through R9 Districts For zoning lots with a height factor of | In R6 Districts | In R7 Districts | In R8 Districts | In R9 Districts Min. Req. Open Space Ratio | Max. Floor Area Ratio | Min. Req. Open Space Ratio | Max. Floor Area Ratio | Min. Req. Open Space Ratio | Max. Floor Area Ratio | Min. Req. Open Space Ratio | Max. Floor Area Ratio 1 | 27.5 | 0.78 | 15.5 | 0.87 | 5.9 | 0.94 | 1.0 | 0.99 2 | 28.0 | 1.28 | 16.0 | 1.52 | 6.2 | 1.78 | 1.4 | 1.95 3 | 28.5 | 1.62 | 16.5 | 2.01 | 6.5 | 2.51 | 1.8 | 2.85 4 | 29.0 | 1.85 | 17.0 | 2.38 | 6.8 | 3.14 | 2.2 | 3.68 5 | 29.5 | 2.02 | 17.5 | 2.67 | 7.1 | 3.69 | 2.6 | 4.42 6 | 30.0 | 2.14 | 18.0 | 2.88 | 7.4 | 4.15 | 3.0 | 5.08 7 | 30.5 | 2.23 | 18.5 | 3.05 | 7.7 | 4.55 | 3.4 | 5.65 8 | 31.0 | 2.30 | 19.0 | 3.17 | 8.0 | 4.88 | 3.8 | 6.13 9 | 31.5 | 2.35 | 19.5 | 3.27 | 8.3 | 5.15 | 4.2 | 6.54 10 | 32.0 | 2.38 | 20.0 | 3.33 | 8.6 | 5.38 | 4.6 | 6.85 11 | 32.5 | 2.40 | 20.5 | 3.38 | 8.9 | 5.56 | 5.0 | 7.09 12 | 33.0 | 2.42 | 21.0 | 3.41 | 9.2 | 5.71 | 5.4 | 7.30 13 | 33.5 | 2.43 | 21.5 | 3.42 | 9.5 | 5.81 | 5.8 | 7.41 14 | 34.0 | 2.43 | 22.0 | 3.44 | 9.8 | 5.92 | 6.2 | 7.52 15 | 34.5 | 2.43 | 22.5 | 3.42 | 10.1 | 5.95 | 6.6 | 7.52 16 | 35.0 | 2.42 | 23.0 | 3.41 | 10.4 | 5.99 | 7.0 | 7.52 17 | 35.5 | 2.42 | 23.5 | 3.40 | 10.7 | 6.02 | 7.4 | 7.52 18 | 36.0 | 2.40 | 24.0 | 3.38 | 11.0 | 6.02 | 7.8 | 7.46 19 | 36.5 | 2.39 | 24.5 | 3.36 | 11.3 | 6.02 | 8.2 | 7.41 20 | 37.0 | 2.38 | 25.0 | 3.33 | 11.6 | 6.02 | 8.6 | 7.35 21 | 37.5 | 2.36 | 25.5 | 3.30 | 11.9 | 5.99 | 9.0 | 7.25 For zoning lots with height factors greater than 21, the minimum required open space ratio shall be as set forth in the following table: OPEN SPACE RATIO FOR HIGH BUILDINGS District | Minimum Required Open Space Ratio at Height Factor of 21 | Additional Required Open Space Ratio for each Additional Height Factor R6 | 37.5 | 0.5 R7 | 25.5 | 0.5 R8 | 11.9 | 0.3 R9 | 9.0 | 0.4 For these zoning lots, the maximum floor area ratio shall be such as can be attained at the required open space ratio for the height factor.* * The floor area ratio attainable at a given height factor and a given open space ratio may be computed from the following formula: [image omitted; see the official code]

Last Amended 12/5/2024

Ask a question about New York law

Corpus searches the New York sections it holds and shows the ones that match, with their citations. Free, no sign-in.