§ 27-346 — Partitions and furring

New York City Administrative Code (current through L.L. 2026/147, enacted September 12, 2026, and amendments effective through October 10, 2026) · NYC Admin. Code § 27-346

Corpus is an independent public-information project, not the official City of New York website. Stable reference: corpuslaw.us/code/1154bf2c-e5ce-4787-a45f-d8ed18a01cf0

§ 27-346 Partitions and furring.

In buildings of construction group I, partitions and furring shall be constructed of noncombustible materials, except that nonbearing partitions that are not required to have a fire-resistance rating, and furring may be constructed of fire retardant treated wood as provided in subdivision (d) of section 27-328 of article three of this subchapter, and except that such partitions and furring, may be constructed of combustible materials in spaces classified in occupancy group E, J-2, or J-3, provided the following conditions are met: (a) the space containing the combustible partitions does not exceed five thousand square feet in area within a noncombustible enclosure having a fire-resistance rating of at least one hour. (b) the space is in a single tenancy. (c) glass or slow burning plastic is used for glazing.

Ask a question about New York law

Corpus searches the New York sections it holds and shows the ones that match, with their citations. Free, no sign-in.