§ 27-702 — Uplift capacity

New York City Administrative Code (current through L.L. 2026/147, enacted September 12, 2026, and amendments effective through October 10, 2026) · NYC Admin. Code § 27-702

Corpus is an independent public-information project, not the official City of New York website. Stable reference: corpuslaw.us/code/5f89ba76-7fc2-45cd-adc5-2bd6441e1348

§ 27-702 Uplift capacity.

A minimum factor of safety against withdrawal of two shall be provided, except that the factor of safety against withdrawal shall be greater than two when the piles are subjected to dynamic uplift loads. The uplift capacity shall be demonstrated by pull-out tests, except where a factor of safety of three or more based on analysis is used, pull-out tests need not be conducted.