§ 40-37 — Appliances in Sleeping Rooms

New York City Administrative Code (current through L.L. 2026/147, enacted September 12, 2026, and amendments effective through October 10, 2026) · 1 RCNY § 40-37

Corpus is an independent public-information project, not the official City of New York website. Stable reference: corpuslaw.us/code/1e075bc6-56b7-40a5-94cb-89261140e465

§ 40-37 Appliances in Sleeping Rooms.

(a) Gas-fueled water heaters shall not be installed in a room occupied for sleeping purposes, in bathrooms, or in any occupied room normally kept closed. (b) It shall be unlawful to install a gas-fueled space heater in a room occupied for sleeping purposes except when the space heater is so designed, installed and operated for it: (1) Obtains combustion air directly from the outside of the building or through a duct leading to the outside. (2) It vents directly to space outside of the building other than an inner court, or is connected through a flue or outlet pipe with an outside chimney which conforms with the requirements of Subchapter 15 of Chapter 1 of Title 27 of the Administrative Code (Building Code). A flue in an existing brick chimney may be used if it is in good condition and tests show that it will provide adequate draft.