PDD-7 — Planned Development District No. 7 - Rochester Science Park Planned Development
Municipal Code, City of Rochester, New York (Rochester Municipal Code, City Charter, Zoning Ordinance and Code Tables current through legislation adopted October 20, 2026 (eCode360 publication RO0104, scraped 2026-11-18)) · Rochester Zoning Ordinance § PDD-7
Corpus is an independent public-information project, not the official City of Rochester website. Stable reference: corpuslaw.us/code/acd8ef4b-a430-48bb-888b-c8d2574a2a00
§ PDD-7: Planned Development District No. 7 - Rochester Science Park Planned Development.
A. Overview; introduction and statement of intent. (1) The property proposed for rezoning to a planned development (PD) district is located in the City of Rochester at 1920 South Avenue and contains approximately 55 acres of gently sloping land and woods, bounded on the west by approximately 325 feet along South Avenue; northwest and north by the Rochester Psychiatric Center; east by the boundary between the City of Rochester and the Town of Brighton and the Monroe Developmental Center; and south by the Green Knolls and Highland Apartments. [See Map 1 of certain maps entitled "Rochester Science Park Development Concept Plan Submission" by Sasaki Associates, Inc., and Sear Brown Associates, P.C. dated November 8, 1985 (referred to herein as the "Development Concept Plan Submission") and the legal description in Exhibit A attached hereto.[1] (2) Uses permitted in this PD district will be restricted to businesses of a scientific or professional use or nature as outlined within this document under acceptable uses. Site amenities, including the woods and trees of special interest or size, are to be retained to the maximum extent feasible. The district, to be identified as the "Rochester Science Park Subdivision" (and to be referred to herein as the "district" or the "Science Park"), will permit one or more subdivision lots (referred to herein as "sites" or "lots") with access from the main drive of the Science Park which intersects South Avenue. A controlled emergency access road connects the main drive's easterly cul-de-sac to a service drive located on the adjoining institutional property. The Science Park is to provide sites needed by expanding high-technology firms and will provide an attractive setting conducive to the requirements of such firms for a quiet environment in close proximity to similar firms and research-related centers. Existing screening of the district's perimeter adjoining institutional and residential uses will be maintained, and additional landscape screening with trees, shrubs and planted berms is to be provided. (3) These PD district regulations are intended to control the development of the Science Park. The intent is to ensure a high-quality campus-style development that is compatible in design and operation with the site and surrounding residential, commercial and institutional uses. The primary objective in establishing design and development criteria is to ensure a sense of continuity in land uses, aesthetic values and environmental sensitivity in the overall development of the Science Park. A high standard is being promulgated in order to create a park that will be distinguished by a consistently high quality of architectural design sympathetically placed in a natural setting. These controls are intended to establish and maintain confidence that the quality and operational characteristics of the overall development will remain high and, therefore, that the economic and environmental values of the Science Park and surrounding area will be protected. (4) In order to achieve these objectives, all plans for building and site design, including special requirements for the preservation of natural site characteristics, and other environmental considerations, will be subject to review by the Project Review Committee ("Committee") in accordance with § 120-190 of the Zoning Code. The Committee will consider each proposal on its design and planning merits. It will judge the particular opportunities, conditions and problems of each parcel with its related development program. The Committee will evaluate each proposal to determine its adherence to high aesthetic standards, sympathy with the natural characteristics, and compatibility with development on adjoining sites or lots and with surrounding institutions and neighborhoods. B. Project review and approval process. (1) Procedures for review and approval of projects within the Science Park are outlined in Article XVII of the Zoning Code. (2) No site or lot in the district shall be developed or improved unless and until a site plan has been approved as provided in Article XVII of the Zoning Code. (3) Incremental development plans that meet a threshold for minor site plan review shall require major site plan review. (4) Site plan review for incremental development within the Rochester Science Park shall require notification to the following: (a) All property owners within the Science Park. (b) All property owners within 100 feet of the boundaries of the Science Park. (c) Official neighborhood contacts. (5) Applications shall include information concerning the handling of hazardous materials and the procedures to be followed in the case of an inadvertent release that could endanger nearby residents and/or institutionalized persons. C. Uses. (1) Purpose and intent. These district regulations are intended to provide an area within the City of Rochester for business or uses of a scientific nature engaged in research, development, professional office and light manufacturing activities. The district regulations are further intended to provide a low-intensity, parklike environment and well-landscaped sites that are in harmony with proximate residential, commercial and institutional uses. (2) Permitted uses: (a) Research in the following: [1] Pharmaceuticals. [2] Antibody and antigen. [3] Agricultural. [4] DNA and genetic. [5] Industrial chemicals to replace noxious chemicals that produce hazardous waste. [6] Biosecurity. [7] Environmental or organic pollutants. [8] Fuel cell. [9] Blood. [10] Nanotechnology. [11] Chemical constituents of body fluids. [12] Clinical and disease detection. [13] Those fields listed in Subsection C(2)(c) below. (b) Medical offices with a research component that is an integral part of the health care which they provide. The research component must consist of a minimum of 20% of the net floor area. (c) Manufacture, processing and assembly of the following: [1] Communications equipment. [2] Data processing equipment, including personal computers, mainframes, microcomputers, hand-held PCS (PDA), and/or the components found in each (including chips and semiconductors). [3] Software. [4] Electronic systems, components and accessories. [5] Photographic/imaging equipment and systems. [6] Optics. [7] Photovoltaic and photonics (light absorption for energy). [8] Fuel cell components. [9] Networking equipment (switches, hubs, fiber and routers among similar components). [10] Industrial and environmental control equipment. [11] Nanotechnology. [12] Products resulting from research as indicated in Subsection C(2)(a) above. (d) Professional offices and firms consisting of the following: [1] Engineering. [2] Financial assistance (consulting, banking and back office excluding branch and drive-through locations). [3] Accounting. [4] Insurance. [5] Architectural. [6] Legal. [7] Planning. (3) Accessory uses. The following accessory uses shall be permitted in addition to those accessory uses defined in § 120-208 of the Zoning Code and in accordance with the terms of § 120-163 of the Zoning Code: (a) Prototype manufacturing incidental to research laboratories and corporate headquarters and offices. (b) Warehousing and storage not occupying more than 15% of the building floor area. (c) Recreational facilities. (d) An additional building for each site, provided it does not exceed 1,000 gross square feet in area and one story in height. (e) Day-care centers serving only the uses located within the district, provided they are located in existing structures in this district. (f) Personal wireless communications facilities, subject to the following conditions: [1] Only as an accessory structure to an approved use. [2] No resale of services. [3] No higher than 150 feet. [4] With submission of FCC documentation. [5] Site ground elevation plus the height of the structure must be below 700 feet. (4) Use limitations. (a) All uses shall be completely enclosed in buildings. No materials, supplies or equipment shall be permitted to remain outside any building. (b) No use shall be conducted in any manner which would render it noxious or offensive by reason of noise, dust, refuse matter, odor, smoke, gas, fumes, vibration or glare. (c) All uses must meet the performance standards as set forth in this development concept plan. D. Bulk, height, setback and parking regulations. (1) Intent. The objective of this section is to assure that the scale, location and mass of buildings in the district are compatible with the existing neighboring residential, commercial and institutional development and environmental quality, and to assure high-quality development. (2) Building and parking area setbacks. (a) Building setbacks shall be not less than 75 feet from any public or private right-of-way line serving more than one lot or site (not including driveways). Parking area setbacks shall be at least 15 feet from any public or private right-of-way line serving more than one lot or site (not including driveways). Notwithstanding the foregoing, no building or parking area setback from any road used only for emergency access shall be required. (b) Building and parking area setbacks shall be not less than 25 feet from the perimeter property line of the district, except for the area in the southeast corner of the district where the setbacks shall be not less than 100 feet as shown on Map 3 of the Development Concept Plan Submission.[2] (c) Building and parking area setbacks within any subdivided lot in the district shall be not less than 10 feet from the property line of any adjoining lot or site in the district, except that no building or parking setbacks will be required from any lot line of any subdivided lot or site which coincides with the lot line for any open space within the district, which open space may be owned by the City and/or by the owner's association; provided, however, that building and parking setbacks of 10 feet shall be required for any lot or site abutting any open space area fronting on South Avenue as generally shown on Map 3.[3] (3) Land coverage. The aggregate coverage by impervious surfaces (including, but not limited to, buildings, walks, drives and parking and loading areas) shall not exceed 70% on any individual subdivided lot in the district. (4) Building height. The maximum building height shall be 45 feet. (5) Parking requirements. (a) The parking requirement for each use shall be determined through the use of a parking demand analysis in accordance with § 120-173B of the Zoning Code. (b) Parking lots shall meet the design and maintenance requirements listed in § 120-173F of the Zoning Code. E. Building design. (1) Intent. The objective in setting building design standards is to obtain consistency and quality in architectural design to protect and enhance values in the district and to provide a high-quality park that will contribute positively to land values and the environmental quality of the surrounding neighborhood. It is intended that a basic design compatibility and architectural harmony will result among the district buildings. (2) Design and development guidelines. Development of buildings and improvements in the Science Park shall be guided by the Design and Development Guidelines attached hereto as Appendix A,[4] as may be amended from time to time, except that to the extent the provisions of this development concept plan conflict with the Design and Development Guidelines, this development concept plan shall control. (3) Screening of roof-mounted equipment. No heating, electrical, air conditioning or other equipment shall be installed on the roof of any building or structure or located on exterior walls unless screened, covered, and installed in a manner which has been approved by the Director of Zoning and Permitting, except that solar energy collectors may be installed on the roof of any building if the design and location thereof is approved by the Director of Zoning and Permitting. Any mechanical equipment must be designed to be an integral part of the building or structure. F. Site design. (1) Intent. These site design standards are intended to provide high-quality building sites and parking areas that contribute to the campus-style character intended for the district and to ensure compatibility with the surrounding uses. Development shall be laid out and each lot or site shall be graded in a manner that is sympathetic to the existing topography. Buildings, roads, and parking areas should be located so as to minimize site disturbance or major divergences from the existing contours of the terrain. Terraced parking arm and stepped buildings shall be deemed to achieve this objective. Disturbed cut and fill areas shall be smoothly blended to meet adjacent existing grades. Each owner and user is encouraged to respect the existing ground plan and topography and adhere to the natural grade as much as possible. (2) Drives and walkways. (a) The width of access and service drives shall be a minimum of 24 feet. Each parcel shall have no more than two access drives from any public or private roadway. (b) Sidewalks shall be a minimum of five feet wide. (3) Exterior service areas. All exterior service loading, storage, and utility areas (including, without limitation, transformers and cooling towers) shall be located at the side or rear of any building, and in any event not between any building and a public or private roadway serving more than one site or lot, and will be screened or sheltered so as not to be visible from the street right-of-way or from adjacent sites. Each building will be permitted one refuse dumpster, located in the service area and screened in accordance with this development concept plan and of a size to be approved by the Director of Zoning and Permitting. No materials, supplies, or equipment shall be permitted to remain outside any building. (4) Signage. Signage will permitted in accordance with § 120-177D for the M-1 District. The design, format and materials of all signs and graphics symbols shall be consistent with the architecture of the district, and shall be guided by the signage section of the Design and Development Guidelines in Appendix A.[5] (a) Minimum setback required: 15 feet from the right-of-way lines and 10 feet from all other lot lines. (b) Type of illumination permitted: internal illumination. (5) Landscaping. (a) To achieve a unified, campus-style setting for the Science Park, landscaping for all areas within lots or sites not covered by buildings, parking and walkways shall be guided by the landscaping section of the Design and Development Guidelines in Appendix A,[6] and a landscaping plan for each site shall be submitted for approval by the Director of Zoning and Permitting. (b) To the extent possible, significant trees and large-caliper (exceeding six inches) trees existing on the site, with particular emphasis on trees located along the perimeter of the district and within the open space area in the district's southeast section, shall be retained. G. Additional requirements. Unless otherwise specified in the above regulations, the requirements in Article XX of the Zoning Code shall apply to uses in the Rochester Science Park. H. Owners' association. In order to provide for the continuing maintenance and administration of the Science Park, the City shall create a not-for-profit corporation or association ("association") to be formed upon the issuance of a certificate occupancy for the building on the final lot or site to be developed in the district. The association shall have certain responsibilities regarding review of future physical changes to any site or lot or improvement thereon and shall be governed by such rules and procedures as shall be established for the governance of the association. [image] Said map and legal description are on file in the City offices.
[Adopted 6-14-2005 by Ord. No. 2005-159 ; amended 6-20-2017 by Ord. No. 2017-167 ; 6-20-2017 by Ord. No. 2017-170 ; 6-17-2025 by Ord. No. 2025-209 ]
Ask a question about Rochester law
Corpus searches the Rochester sections it holds and shows the ones that match, with their citations. Free, no sign-in.
