Sec. 74-503. - Requirements.
(a) Where protection is required. The water system shall be required to maintain a degree of protection commensurate with the degree of hazard regardless of whether the hazard is immediate or potential. This may include but not be limited to the presence and use of water boilers for heating systems. To that extent, the Cross Connection Control Manual published by NYSDOH shall be used as a guide to determine where protection is required. It shall be the responsibility of the water user to provide and maintain such required protection devices, and such devices shall be of a type acceptable to the New York State Department of Health. (b) Type of protection. The protective device required shall depend on the degree of hazard as tabulated below. (1) At the service connection to any premises where there is an auxiliary water supply handled in a separate piping system with no known cross contamination, the public water supply shall be protected by an approved reduced pressure zone device. (2) At the service connection to any premises on which a substance that would be objectionable (but not necessarily hazardous to health) if introduced into the public water supply is handled so as to constitute a cross connection, the public water supply shall be protected by an approved double check valve assembly. (3) At the service connection to any premises on which a substance of unusual toxic concentration or danger to health is or may be handled but not under pressure, the public water supply shall be protected by an air gap separation or an approved reduced pressure zone backflow prevention device. If an air gap is installed, it shall be located as close as practicable to the water meter, and all piping between the water meter and receiving tanks shall be entirely visible. A reduced pressure zone device when installed shall be located as close as possible to the property line. (4) At the service connection to any premises on which any material dangerous to health is or may be handled under pressure, the public water supply shall be protected by an air gap separation. The air gap shall be located as close as practicable to the water meter and shall be accessible. (5) At the service connection to any sewage treatment plant or sewage pumping station, the public water supply shall be protected by an air gap separation. The air gap shall be located as close as practicable to the water meter and all piping between the water meter and receiving tanks shall be entirely visible. If these conditions cannot be reasonably met, the public water supply shall be protected by an approved reduced pressure zone backflow prevention device and it shall be located as close as possible to the property line. (c) Frequency of inspection of protective devices. It shall be the duty of the water user on any premises on which backflow protective devices are installed to have inspections by a NYS Department of Health certified backflow prevention device inspector made at least once a year, or more often in instances where successive inspections indicate repeated failure. Devices shall be repaired, overhauled or replaced at the expense of the water user whenever the devices are found to be defective. These tests shall be performed by a qualified backflow prevention device tester, and all test results will be provided to the water user within 72 hours after the test is made. Records of such tests, repairs, and overhaul shall also be kept and made available to the water users and the local health department upon request. (d) Inspection after installation. The CEO or plumbing inspector shall make an inspection of the initial installation of any backflow protective devices required pursuant to this article to ensure compliance with this Code and the Cross Connection Control Manual. Devices shall be repaired, overhauled or replaced at the expense of the water user if the devices are found to be defective by the CEO or plumbing inspector. The fee for such inspection is set forth in Appendix B—Fee Schedule to this Code.
(Ord. No. 8820, 4-10-13; Ord. No. 8930, 4-23-14)
Ask a question about Rome law
Corpus searches the Rome sections it holds and shows the ones that match, with their citations. Free, no sign-in.
Use the Rome code through the API
This call searches the Rome code. Change jurisdiction to the state's code to search its statutes and its cities, or to US for federal law. A free key gives 1,000 searches a month, and the MCP server works with no key.
curl -H "Authorization: Bearer $CORPUS_API_KEY" \
"https://corpuslaw.us/api/v1/search?q=Requirements&jurisdiction=NY-ROME"Law search API · Docs · Get a free key · Connect the MCP server