§ 16-13 — School buildings
Code of Ordinances of the City of Syracuse, New York (Supp. No. 41: codified through September 30, 2024) · Syracuse Special Acts § 16-13
Corpus is an independent public-information project, not the official City of Syracuse website. Stable reference: corpuslaw.us/code/6c3394d9-30e2-45ba-8495-e94724ec35cb
Sec. 16-13. - School buildings.
The commissioner of public works shall have the power, when authorized so to do by the board of estimate and apportionment for, on behalf of and in the name of the city of Syracuse to acquire by purchase or condemnation or to lease such real property as may be required for school purposes; to superintend the planning and construction of new school buildings; and to dispose of such real property owned and used for school purposes as shall no longer be required therefor. No school building or addition to a school building shall hereafter be erected until the plans, specifications and detailed drawings for the same shall have been approved by the superintendent of public works and board of education and their respective approvals endorsed thereon. Such plans and specifications shall show in detail the ventilation, heating, lighting, plumbing and sanitary arrangements of such buildings. No plan or specifications for the erection of any school building or addition to a school building shall be approved unless the same shall provide at least fifteen (15) square feet of floor space and two hundred (200) cubic feet of air space for each pupil to be accommodated in each study or recitation room therein, nor unless provision be made therein for assuring at least thirty (30) feet of pure air every minute per pupil and the facilities for exhausting foul or vitiated air therefrom shall be positive and independent of atmospheric changes. All such school buildings shall have at least two (2) separate and distinct stairways located as far remote from each other as practicable. All stairs, stairways and stair halls shall be constructed of absolutely fireproof material. All stairways and stair halls shall be enclosed on all sides with walls of solid masonry, self supported and carried from the foundations. All doorways opening therein shall be protected by fire doors and all window openings, except from the outside, shall have fireproof or wired glass set in metallic frames. All halls, doors, stairways, seats, passageways and aisles, and all lighting and heating appliances and apparatus shall be so arranged as to facilitate egress in case of fire or accident, and to afford the requisite and proper accommodations for public protection in such cases. Existing school buildings shall, as far as practicable, be improved so as to comply with the foregoing requirements.
(N.Y. Laws 1907, Ch. 543, § 13)
Ask a question about Syracuse law
Corpus searches the Syracuse sections it holds and shows the ones that match, with their citations. Free, no sign-in.
