Sec. 16-25. - Fire services.

Services may be installed for fire protection purposes. The city reserves the right to limit the size of a pipe used depending on local conditions; as to the size of the main in the street, length of the proposed service in feet, quantity of water available and pressure. Applications for a permit to install a fire service, accompanied by a plan of the proposed piping system must be submitted to the city engineer for approval after prior review by the fire department and issuance of a building permit. No change or additions to existing systems shall be made on the street side of the check valve or any part of the system involving antifreeze loops, without a permit from the city engineer. Such permit will be issued only when plans of proposed changes have been submitted and approved by the city engineer. Except in unusual cases where it would be economically impractical to do otherwise, separate services for fire and domestic use will be required from main to building or other point of use on private property. special combination domestic and fire service shall only be permissible provided that the service is fully metered and that the fire demand does not exceed the maximum meter capacity. Meters shall be sized by water division personnel according to the domestic demand criteria specified in the Onondaga County Plumbing Code and the maximum meter capacity as specified by the Standard Specifications of the city engineer on file. Building plans shall be provided to the Syracuse Water Division showing all domestic fixtures. Sprinkler plans shall include sprinkler head flow and pressure requirements and system flow requirements in galls-per-minute. The number of sprinkler heads in a single sprinkler design area shall not exceed six (6) for combination services. Combination service installations shall be limited to no larger than two-inch diameter piping and shall conform to the Standard Specifications for Combined Fire Services of the city engineer, on file and New York State cross connection control criteria.

(Ord. No. 206-1974, Art. 25, 4-9-74; Ord. No. 552-92, 12-21-92)

Ask a question about Syracuse law

Corpus searches the Syracuse sections it holds and shows the ones that match, with their citations. Free, no sign-in.