Sec. 27-26. - Non-habitable space.
(a) Height. Non-habitable space, except crawl spaces and attics, in buildings shall have a minimum height of seven (7) feet measured from floor to ceiling. (b) Toilet rooms and bathrooms. (1) Toilet rooms and bathrooms shall have provisions for privacy. (2) Toilet rooms and bathrooms for dwelling units in multiple dwellings, shall be located within the dwelling units and shall be accessible from any sleeping room without passing through any other sleeping room. (3) Unless located within dwelling units or directly connected with sleeping rooms, toilet rooms and bathrooms in multiple dwelling shall be provided in each story containing habitable space, and shall be accessible thereto. (4) Toilet rooms for employees shall be in separate rooms for each sex where there are five (5) or more employees, shall be readily accessible to such employees and shall not open directly into any public kitchen or other public space used for the cooking or preparation of food. (5) In all buildings, floors of bathrooms, toilet rooms and similar spaces shall be waterproof; such waterproofing shall extend four (4) inches or more above floors except at doors, so that floors can be flushed or washed without leaking. Walls shall be constructed or covered with a moisture-resistant material. (6) All shower enclosures shall have waterproof floor and water-resistant walls. (c) Light and ventilation. (1) Kitchenettes, bathrooms, and toilet rooms shall be provided with electric light appropriate for the use of such rooms. (2) Laundry rooms, furnace rooms, and similar nonhabitable space shall be provided with electric light appropriate for the intended use of such rooms. (3) Stairs shall be provided with electric light to allow safe ascent or descent. (4) Kitchenettes, bathrooms, and toilet rooms shall be provided with ventilation in accordance with either of the following: a. Natural ventilation as required for habitable space, except that such operable areas shall be not less than one and one-half (1½) square feet for bathrooms or toilet rooms and not less than three (3) square feet for kitchenettes; or b. Mechanical ventilation exhausting not less than one (1) cubic foot per minute ("CFM") for each square foot of floor area for bathrooms and toilet rooms and not less than four (4) CFM for each square foot of floor area of kitchenettes. (5) Spaces in multiple dwellings which contain central heat producing air conditioning and other equipment, shall be ventilated to the outer air, and air from these spaces shall not be recirculated to other parts of the building. (6) Ventilation shall be provided in unheated attics, spaces below flat roofs, and in crawl spaces. Location and net areas of ventilation openings shall be such as to minimize deterioration of structural members from condensation or other causes, in conformity with generally accepted standards.
(Gen. Ord. No. 30-1993, 6-28-93)
Ask a question about Syracuse law
Corpus searches the Syracuse sections it holds and shows the ones that match, with their citations. Free, no sign-in.