§ 27-33 — Interior protection
Code of Ordinances of the City of Syracuse, New York (Supp. No. 41: codified through September 30, 2024) · Syracuse Code of Ordinances § 27-33
Corpus is an independent public-information project, not the official City of Syracuse website. Stable reference: corpuslaw.us/code/8a8b5a71-21df-4cc5-b729-3ac8600f4e61
Sec. 27-33. - Interior protection.
(a) Free from dampness: (1) Cellars, basements and crawl spaces, in every structure or building shall be reasonably free from dampness to prevent conditions conducive to decay or deterioration of the structure. (2) Ventilation shall be provided in every basement, cellar, crawl space, and attic by means of windows, openings or vents, or mechanical vents in accordance with generally accepted standards. (b) Structural members: (1) Supporting structural members of every structure or building shall be structurally sound. (2) Supporting structural members shall be considered to be structurally sound if such members are capable of bearing imposed dead and live loads safely and if there is no evidence of deterioration. (c) Chimneys, flues and vents: (See also section 27-55) (1) Chimneys and all flue and vent attachments thereto, and all other flues and vents of every structure or building shall be structurally sound and free from defects to assure the performance of the function for which they were designed and are used. (2) Chimneys, flues, gas vents or other draft-producing equipment shall provide sufficient draft to develop the rated output of the connected equipment. Chimneys, flue linings, where required, flues, gas vents and their supports, shall be structurally safe, durable, smoke tight and capable of withstanding the action of the flue gases. (d) Stairs and railings: (1) Interior stairs, of every building or structure shall be structurally sound and free from defects. Railings shall be provided in accordance with generally accepted standards for stairs, balconies, landings and stairwells. (2) Treads or risers that evidence excessive wear or are broken, warped or loose shall be repaired. Stairs shall be securely fastened to supporting structural members and be capable of supporting normally imposed loads. Properly balustraded railings, capable of bearing normally imposed loads, shall be placed on the open portions of stairs, balconies, landings and stairwells. (e) Floors, walls and ceilings: (1) Floors, walls and ceilings of every building or structure shall be structurally sound and maintained free of deterioration in a clean and sanitary condition. (2) Floors shall be considered to be structurally sound where capable of safely bearing imposed loads. Walls and ceilings shall be considered to be structurally sound and in good repair when clean, free from breaks, loose plaster and similar conditions.
(Gen. Ord. No. 30-1993, 6-28-93)
Ask a question about Syracuse law
Corpus searches the Syracuse sections it holds and shows the ones that match, with their citations. Free, no sign-in.