Sec. 7-7-6. - Connection specifications.
(a) Except as otherwise provided herein, connections to sanitary sewers and storm water drains shall be made by means of forty-five (45) degree or ninety (90) degree M-D cut-in connections of approved size, as manufactured by Joseph G. Pollard Co., Inc., or approved equal. (b) The use of an existing Y-branch, or other existing fitting, for the purpose of connecting a service line thereto, shall be allowed only when such branch or fitting is already available and in place as part of sanitary sewer or storm water drain, is in satisfactory condition and at an acceptable location, and is of adequate size to receive said service line. (c) A manhole shall be built over a sanitary sewer or storm water drain at the point of connection, whenever the proposed service line to be connected is five (5) inches or greater and the sanitary sewer or storm water drain is eight (8) inches or less, or when the proposed service line is greater than six (6) inches and the sanitary sewer or storm water drain is ten (10) inches or more, unless otherwise specifically authorized. The above sizes refer to the internal diameter of the pipes or conduits. (d) M-D cut-in connections and other approved types of connections shall be installed in such a manner that the invert of said connection shall be higher than the invert of sanitary sewer or storm water drain by an amount not less than one-half (½) the vertical diameter of said sanitary sewer or not less than three-fourths (¾) the vertical diameter of said storm water drain unless otherwise authorized by the commissioner of public works. (e) Connections to an existing cast iron pipe sanitary sewer or storm water drain shall be made by burning an opening in said pipe in an approved manner or by such other means as may be authorized by the commissioner of public works. (f) When a connection is made into an existing manhole or when a manhole is required to be built at the point of connection, as specified herein above, the invert of the service line at the point of connection shall be higher than the invert of the sanitary sewer or storm water drain by an amount not less than the vertical diameter of said sanitary sewer or storm water drain, unless otherwise authorized by the commissioner of public works. (g) When the difference in invert elevation in the manhole at the point of connection exceeds three (3) feet, a drop connection shall be installed in said manhole. (h) Adequate provision shall be made so that the discharge from a service line within a manhole shall be conducted smoothly into, and in the direction of flow of, the main channel of the sanitary sewer or storm water drain by means of a built-up channel or by extending said service line partly into the manhole as may be necessary and in such manner as may be approved by the commissioner of public works. (i) Construction of new manholes, drop connections and any other necessary structures and connections to existing structures, shall conform with such specifications as may be promulgated by the commissioner. In general, the current standard specifications and construction details of the department of public works shall be followed, subject to the prior approval of the commissioner of public works. (j) In areas where a low-pressure sewer system exists or is required, each individual building shall be connected to the low pressure sewer system with a pumping system, approved by both the Commissioner of Public Works and the Westchester County Health Department for said low pressure sewer system. (k) For properties connected to a low pressure sewer system, the discharge of the following items is prohibited in order to extend the operation of the individual property pump in a low pressure sewer system: solid or viscous substances in quantities or size capable of obstruction of the flow in the sewers or other interference with the proper operation of the wastewater facilities. (l) No person(s) shall discharge or cause to be discharged any material capable of resisting the flow of sewage, harm either the sewers, sewage treatment process or equipment or have an adverse effect on a downstream facility. (m) No person shall connect roof downspouts, foundation drains, area way drains or other sources of surface runoff or groundwater or water from condensing and cooling apparatus to a public sanitary sewer. (n) The Commissioner of Public Works and other duly authorized employees of the City shall be permitted to enter all properties for the purposes of inspection, observation, measurement, sampling, making necessary repair or replacement to the duly approved pump and chamber in order to ensure the correct operation of the low pressure sewer system.
(Ord. of 12-20-07, § 2; Ord. of 9-6-22)
Ask a question about White Plains law
Corpus searches the White Plains sections it holds and shows the ones that match, with their citations. Free, no sign-in.