§ 7-8-52 — Installation

Municipal Code of the City of White Plains, New York (Codified through Ordinance of October 5, 2026. (Supp. No. 79, Update 2)) · White Plains City Code § 7-8-52

Corpus is an independent public-information project, not the official City of White Plains website. Stable reference: corpuslaw.us/code/cf8508b5-c023-4412-a3c5-d447d5c66795

Sec. 7-8-52. - Installation.

(a) In general, and unless otherwise specified, new service line(s) and replacement of existing service lines shall be a minimum of one (1) inch in diameter. Service lines up to and including two (2) inches in diameter shall be of copper tubing (type K) with flared joints and service lines greater than two (2) inches in diameter shall be of cast iron or ductile iron cement lined pipe. All materials and methods of installation shall conform to the latest requirements as specified in the City of White Plains "Standard Construction Specifications" and "Standard Construction Details" (latest version) as well as the New York State Building and Plumbing Codes. Where there are conflicting requirements between code sections, the more restrictive requirement shall prevail. (b) The property owner, or their duly authorized representative, shall do all work necessary for the installation of the service line and/or fire main, including but not limited to excavation, shoring, backfilling, dewatering, piping, fitting, tie rods, restraints, thrust blocks and surface restoration in a manner satisfactory to the commissioner. Tapping and making connections to the City's water main shall be performed by the City of White Plains Bureau of Water for service lines up to and including 4 inches in diameter. For service lines greater than 4 inches in diameter, a tee and valve connection shall be installed in accordance with detail in section 7-8-124 at the owner's expense. At the Commissioner's discretion, this tee and valve installation may be required for other service lines 4 inches in diameter or less at the owner's expense. Line stops or insertion valves may be required for those service line installations at the owner's expense. (c) In general the trenches excavated for water service lines shall be straight and perpendicular to the City's water main and to a sufficient depth so that said service lines and/or fire mains can be laid with not less than four and one-half (4½) feet of cover and not more than six and one-half (6½) feet of cover below the existing or future street surface as established by the commissioner, whichever is lowest. If the City's main is in an unusual location or because of solid rock, the commissioner may grant permission to install the line(s) in another accepted manner. If the conditions are such that the service line(s) will have less than four and one-half (4½) feet cover, it shall be insulated with an approved protective covering. All trench excavations shall be protected in accordance with applicable OSHA regulations. (d) No tap shall be made by the City of White Plains Bureau of Water until the depth of the trench and dimensions of excavation are such as will allow adequate room for tapping the main and for the installation of the service line(s) as shown in section 7-8-124 of this Code, and/or as may be determined and required by the commissioner. The permittee shall notify the commissioner not less than twenty-four (24) hours in advance, exclusive of Saturdays, Sundays and holidays, that the trench is ready for the tap and installation of the service line(s). (e) Not more than one (1) building shall be connected to any one (1) tap and service line. The commissioner may, at their discretion, grant permission to connect accessory buildings to the service line on the same building lot. (f) There shall be no alterations made in the service line and/or fire main or appurtenances, and no additional appurtenances shall be installed on the street or inlet side of the official water meter unless approved in writing by the commissioner. (g) Separate service lines are required for domestic and fire protection water systems. Domestic service lines in all cases shall be separate from fire service lines and fire mains. The Commissioner may, at their discretion, permit a single combined domestic water/fire protection service line under the following conditions: (1) The proposed combined service line size shall be based upon hydraulic calculations prepared by a New York State licensed design professional in accordance with the New York State Building Code, Fire Code and NFPA referenced standards. (2) The combined service line shall be capable of simultaneously supplying domestic and fire protection demands. (3) A combined service line will not be considered for the following occupancy classifications: (i) Group I (ii) Group R-2 (where there are more than 12 dwelling units) (4) A written request along with hydrant flow test data (collected within 6 months of request date), hydraulic calculations and fire protection system design documents shall be submitted to the Commissioner with a copy being submitted to The City of White Plains Building Department. Fire service lines and fire mains shall be not be less than four (4) inches in diameter sized per the New York State Building Code, Fire Code and NFPA referenced standards.

(Regs. of 3-5-79, § 3.02; Regs. of 7-3-85; Ord. of 4-1-24, § 3)

Ask a question about White Plains law

Corpus searches the White Plains sections it holds and shows the ones that match, with their citations. Free, no sign-in.