§ 111.177 — Floors, walls and ceilings
Akron, Ohio, Municipal Code (Supp. No. 64: codified through Ordinance No. 40-2026, enacted February 9, 2026) · Akron Codified Ordinances § 111.177
Corpus is an independent public-information project, not the official City of Akron website. Stable reference: corpuslaw.us/code/7cc85b78-2fa9-4af8-8236-36ef21c887dc
111.177 - Floors, walls and ceilings.
A. Floors. 1. Floors, mats, carpets and other floor coverings shall be kept clean. 2. Floors and floor coverings of all food preparation, food service, food storage and utensil washing areas, garbage or refuse storage rooms, and the floors of all walk-in refrigerating units, dressing rooms, locker rooms, toilet rooms and vestibules shall be constructed of smooth, durable, non-absorbent material such as sealed concrete, terrazo, ceramic tile, durable grades of linoleum, vinyl, or plastic, or tight wood impregnated with plastic and shall be maintained in good repair. Nothing in this section shall prohibit the use of anti-slip floor covering in areas where necessary for safety reasons. 3. Carpeting, if used as a floor covering, shall be of closely woven construction, properly installed, easily cleanable, and maintained in good repair. Carpeting shall not be used in food preparation areas, equipment and utensil washing areas, food storage areas, and in toilet room areas where urinals or toilet fixtures are located. 4. Mats shall be of non-absorbent, grease-resistant materials and of such size, design, and construction as to facilitate cleaning. 5. In all new or extensively remodeled food establishment operations in which water-flush or wet mop cleaning methods are used, the junctures between walls and floors shall be covered and sealed. In all other cases, the juncture between walls and floors shall not present an open seam. 6. Exposed utility service lines and pipes should be installed in a way that does not obstruct or prevent cleaning of the floor. In all new or extensively remodeled food establishment operations, installation of exposed horizontal utility lines and pipes on the floor is prohibited. B. Walls and Ceilings. 1. Walls and ceilings, including doors, windows, skylights and similar closures shall be maintained clean and in good repair. 2. Light fixtures, vent covers, fans, and similar equipment attached to walls or ceilings shall be cleanable and shall be maintained clean and in good repair. 3. Walls, including non-supporting partitions and wall coverings, and ceilings of walk-in refrigerating units, food preparation areas, equipment washing and utensil washing areas and toilet rooms shall be smooth, non-absorbent, and cleanable. Concrete or pumice blocks used for interior wall construction in these locations shall be finished and sealed to provide an easily cleanable surface. 4. Studs, joists, and rafters shall not be exposed in walk-in refrigerating units, food preparation and storage areas, equipment and utensil washing areas, and toilet rooms. If exposed in other rooms or areas, they shall be finished to provide an easily cleanable surface. 5. Exposed utility service lines and pipes should be installed in a way that does not obstruct or prevent cleaning of the walls and ceilings. Utility service lines and pipes should not be exposed on walls or ceilings in walk-in refrigerating units, food preparation areas, equipment and utensil washing areas, and toilet rooms. 6. Wall and ceiling covering materials shall be attached and sealed so as to be cleanable.
(Ord. 515-1997)
Ask a question about Akron law
Corpus searches the Akron sections it holds and shows the ones that match, with their citations. Free, no sign-in.
