§ 93.53 — Fire hydrants

Akron, Ohio, Municipal Code (Supp. No. 64: codified through Ordinance No. 40-2026, enacted February 9, 2026) · Akron Codified Ordinances § 93.53

Corpus is an independent public-information project, not the official City of Akron website. Stable reference: corpuslaw.us/code/8b2ac87a-6828-4fe0-b56a-ded4c928b80b

93.53 - Fire hydrants.

A. Opening, damaging or Obstructing Fire Hydrants. No person shall open or attempt to open or draw water from any fire hydrant without the consent in writing of the Mayor or Fire Chief, or in any manner damage, deface, or obstruct the use of any fire hydrant, or place or keep any obstruction, article, or material of any kind in front of any such hydrant, between the curb line and the center of the street, or within five feet of either side of such hydrant. B. Fire Hydrant Systems. Plans for fire hydrant systems shall be submitted to the Akron Fire Department for review and approval. 1. Fire hydrants are to be shown on the site plan submitted to the Fire Department. The plan must show the water mains and the size of the pipe must be labeled. 2. All fire hydrants and water mains located in or on parking structures shall be protected from freezing by means other than heat tape. 3. The Fire Department connection shall be a five-inch Storz fitting with a downward angle of 30° and located on the street-side of the building, unless otherwise approved by the Chief of the Bureau. 4. The Fire Department connection must be located beyond the building collapse zone, whenever possible. 5. The Fire Department connection must be located within thirty feet of a fire hydrant, whenever possible, but shall be no more than one hundred feet from a fire hydrant. 6. The Fire Department connection shall have a sign immediately adjacent to the connection, and visible from the public right-of-way that states "FDC" in red letters no less than six inches tall, and includes the street number of the building in red numerals no less than two inches tall, with a white-reflective background. 7. All private fire hydrants shall be painted red. 8. No weep or drip valve shall be installed underground unless observed and approved by the Chief of the Bureau. C. Where Required. Where a portion of the facility or building hereafter constructed or moved into or within the jurisdiction is more than four hundred feet from a hydrant on a fire apparatus access road, as measured by an approved route around the exterior of the facility or building, on-site fire hydrants and mains shall be provided where required by the code official. Fire hydrants shall provide a flow of at least one thousand gallons per minute twenty-PSI residual at flow and meet the fire flow requirements for buildings. Exception shall be made for portions of building equipped throughout with an approved automatic sprinkler system installed in accordance with Sections 903.3.1 or 903.3.1.2 of the Ohio Building Code. for which the distance requirement shall be six hundred feet. D. Inspection. Testing and Maintenance. Fire hydrant systems shall be subject to periodic testing as required by the Code Official. Fire hydrant systems shall be maintained in an operative condition at all times, and shall be repaired where defective. Additions, repairs, alterations and servicing shall comply with the approved standards set forth in National Fire Protection Association Rule 25. E. Private Fire Service Mains and Water Tanks. Private fire service mains and water tanks shall be periodically inspected, tested and maintained in accordance with National Fire Protection Association Rule 25 at the following intervals: 1. Private fire hydrants (all types): Inspection annually and after each operation; flow test and maintenance annually. 2. Fire service main piping: Inspection of exposed main piping must be done annually; flow test must be performed every five years. 3. Fire service main piping strainers: inspection and maintenance after each use. F. Obstruction, posts, fences, vehicles, plant growth, trash, storage, and other materials or objects shall not be placed or kept near fire hydrants, fire department inlet connections or fire protection system control valves in a manner that would prevent such equipment or fire hydrants from being immediately discernible. The Fire Department shall not be deterred or hindered from gaining immediate access to fire protection equipment or fire hydrants. G. Clear Space Around Hydrants. A three foot clear space shall be maintained around the circumference of fire hydrants except as otherwise required or approved. H. Physical Protection. Where fire hydrants are subject to impact by a motor vehicle, guard posts or other approved means shall comply with the following standards: 1. Posts. Guard posts shall comply with all of the following requirements: a. Constructed of steel not less than four inches in diameter and concrete filled. b. Spaced not more than four feet between posts on center. c. Set not less than three feet deep in a concrete footing of not less than a fifteen-inch diameter. d. Set with the top of the posts not less than three feet above ground. 2. Located not less than three feet from the protected object. 3. Other Barriers. Physical barriers shall be a minimum of thirty-six inches in height and shall resist a force of twelve thousand pounds applied thirty-six inches above the adjacent ground surface.

(Ord. 474-2002; Ord. 595-1996; Ord. 578-1992; Ord. 282-1981) (Ord. 291-2013; Ord. 305-2020)

Ask a question about Akron law

Corpus searches the Akron sections it holds and shows the ones that match, with their citations. Free, no sign-in.