§ 3129.02 — Snow Load
Codified Ordinances of the City of Cleveland, Ohio (2026 S-28: current through legislation passed October 19, 2026) · Codified Ordinances of Cleveland § 3129.02
Corpus is an independent public-information project, not the official City of Cleveland website. Stable reference: corpuslaw.us/code/2a3bb8cf-99b5-42ed-b27f-1b88754a208c
§ 3129.02 Snow Load
BOCA Section 911.0 entitled “Snow Load” is hereby amended to read as follows: Section 911.0 Snow Load. (a) In addition to the dead load, and in addition to the wind load, roofs shall be designed for the loads per square foot of horizontal projection given in the following Table: Slope of Roof | Roof Load per Square Foot of Horizontal Projection Less than 4 vertical to 12 horizontal | 30 pounds 4, or more, vertical to 12 horizontal, up to 12 vertical to 12 horizontal | 20 pounds Over 12 vertical to 12 horizontal | 0 pounds Ordinary roofs, either flat, or pitched shall be designed for the live loads specified in the Table above or the Snow Load specified in OBBC, whichever is greater.